Manual and
Installation Guide
BB10012
Страница 1: ...Manual and Installation Guide BB10012...
Страница 2: ...8V can be used when connected to shore power Equalization Equalization is not recommended for our batteries Most chargers will allow you to shut this feature off or use a setting that does not use equ...
Страница 3: ...temperature 135F The BMS will not allow a charging or discharging current Low temperature 25F The BMS will not allow a charging current High Current The BMS will not allow a current that exceeds 100...
Страница 4: ...washers may be removed or longer bolts may be required in order for the bolt to fully seat into the nylon insert of the nut WHEN CONNECTING TO BATTERY TERMINALS DO NOT FINGER TIGHTEN ALL CONNECTIONS M...
Страница 5: ...B10012 battery using a 12V charger prior to connecting them in series in order to ensure that they are at the same state of charge Inverter Chargers and other devices having large input capacitance 10...
Страница 6: ...enance if any at all If your batteries are in series and not being charged by a multi bank charger it is recommended that you fully charge the batteries individually once a year This will balance out...
Страница 7: ...r manufacturers defect warranty from the date of purchase see attached Warranty We also warrant all other complimentary products inverters converters chargers etc we sell are free from defect for 30 d...
Страница 8: ...return form at https battlebornbatteries com returns Refunds Once we receive your item we will inspect it and notify you that we have received your returned item We will immediately notify you on the...
Страница 9: ...y further questions or need help with anything regarding your battery please do not hesitate to contact us Battle Born Batteries Address 4814 Longley Ln Reno NV 89502 Email info battlebornbatteries co...