background image

14

Maintenance

• 

Clean the Comfort Cushion after each 

use. 

NOTE: 

It is especially important to 

thoroughly clean your Comfort Cushion 

after each bath if ‘Dettol’ or similar 

products have been added to the bath 

water.

• 

Regularly check that the suction cups are 

secure and undamaged; these are screwed 

onto threaded studs on the underside of 

the Comfort Cushion and should only be 

hand tight (fig.14).

• 

Check that the air hose and connector are 

not damaged.

The Airflo 12 has been designed to be 

maintenance free and apart from replacing the 

battery, the Airflo 12 contains no other user 

serviceable parts.

Battery replacement:

• 

Turn the Airflo

 

12 onto its end containing 

the air outlet socket, remove the screw (

A

 

fig. 15) and slide the end panel (

B

) away 

from the housing.

 

• 

Disconnect the wire from the battery pack 

and remove the battery pack from the 

battery compartment.

• 

Fit the replacement battery pack, 

ensuring 

that the connector is secure, refit the end 

panel and secure the screw (

A

).

When it becomes apparent that the Airflo

 

12

 

is producing fewer than expected lifting cycles, 

the battery is probably reaching the end of its 

working life and should be replaced.

14

A

B

15

Содержание Comfort Cushion

Страница 1: ...User Instructions 41100060951 Comfort Cushion...

Страница 2: ...the Comfort Cushion in the bath 8 Connecting the air hose and hand control 9 Dry trials without water in the bath 9 Using the Comfort Cushion 10 To remove the Comfort Cushion from the bath 12 Cleanin...

Страница 3: ...en cleaning the bath or when reaching into the bath to retrieve items as doing so may place an uneven or unbalanced load on the Comfort Cushion causing it to become unstable The Comfort Cushion should...

Страница 4: ...o inflate the Comfort Cushion The suction cups contain Latex Users with an allergy to Latex should take particular care to avoid prolonged contact with the suction cups The suction cups are situated a...

Страница 5: ...ver be used outside of a bath When properly maintained the Comfort Cushion will give many years of trouble free service Construction The Comfort Cushion is constructed from a very strong polyurethane...

Страница 6: ...attery charge has become low To determine the true battery state following a lift press the Battery Status Indicator button and the lights will indicate the battery charge state IMPORTANT To maximize...

Страница 7: ...light will be flashing green After 2 hours the lights will change to two steady green and one flashing green After 16 hours all lights will become steady green NOTE If charging is momentarily interrup...

Страница 8: ...air inlet valve B can be rotated allowing the hose to be led to the appropriate corner Fitting the Comfort Cushion in the bath Fold the backrest over onto the seat as indicated in fig 3 Lightly place...

Страница 9: ...the Comfort Cushion to secure the suction cups to the floor of the bath Check all four suction cups are securely stuck to the bath Wet them to help them stick if necessary Whilst still clothed and wit...

Страница 10: ...yourself into the bath KEEP YOUR KNEES BENT AND FEET FLAT ON THE FLOOR OF THE BATH AS YOU ARE LOWERED SO AS TO AVOID SLIDING FORWARDS ON THE SEAT Hold the sides of the bath or grab handles for added...

Страница 11: ...old the sides of the bath for added support if required Select Up on the hand control when you are ready to get out of the bath You can stop at any time by releasing the Up button Select Up again to c...

Страница 12: ...e remaining pair of suction cups by lifting their rims as before Remove the Comfort Cushion from the bath and disconnect the air hose NOTE To deflate the Comfort Cushion when not sitting on it disconn...

Страница 13: ...nflated in between uses to allow air to circulate around it and reduce the risk of mould forming on the surface of the product Do not leave in bright sun light Do not dry using hot air Disinfection Co...

Страница 14: ...to be maintenance free and apart from replacing the battery the Airflo 12 contains no other user serviceable parts Battery replacement Turn the Airflo 12 onto its end containing the air outlet socket...

Страница 15: ...site When the Airflo 12 has reached the end of it s working life remove the battery for safe disposal in accordance with your local council guidelines and dispose of the Airflo 12 at your local house...

Страница 16: ...essure 0 25 bar Battery 1 x 12v 2200mAh Ni MH battery pack Battery Life Greater than 500 charging cycles 2 5 years depending on usage Environmental protection Airflo 12 housing IP51 Protection against...

Страница 17: ...he instructions before use Refer to the instructions Recycle Do not dispose of in household waste Date of manufacture Max Min operating environment temperature Duty cycle I Operating time O Non operat...