background image

B A T H O L O G Y

r e d i s c o v e r   b a t h i n g

A t m o s p h e r i c  310

I n - S h o w e r   V e n t i l a t i o n

Installation and Operation Manual

Содержание Atmospheric 310

Страница 1: ...B A T H O L O G Y r e d i s c o v e r b a t h i n g A t m o s p h e r i c 310 I n S h o w e r Ve n t i l a t i o n Installation and Operation Manual ...

Страница 2: ... 3x Vibration Isolation Grommet 4x 1 Screws 3x 7 16 Screws A C E 3x Damper Screws 2x Mounting Screws 1x Timer Face Ivory 1x Timer Face Almond 2 1x Slide Speed Control 2x Mounting Screws 13 13 15 D 3x Wire Nuts Electronic Time Control Fan Damper Slide Speed Control Optional H Flex Duct 4 x25 1x 18 18 19 Mastic Tube Net Contents 1 12 Gallon 1x Flex Duct Tie 36 4x Flex Duct Tie 18 4x Duct K 18 18 19 ...

Страница 3: ...s 2x 3 8 Short Screws B 17 17 F 17 17 G 1x 9 9 12 Expansion Vent Housing 4 duct 1x Expansion Vent Halogen Light 1x Expansion Vent Grille 4x Hanger Bars 4x 1 Long Screws 2x 3 8 Short Screws B 1x Expansion Vent LED Light 1x Expansion Vent Grille 1x 9 9 12 Expansion Vent Housing 4 duct 4x Hanger Bars 4x 1 Long Screws 2x 3 8 Short Screws B No Light Roof Cap Wall Vent Halogen LED Vent Options Expansion...

Страница 4: ...c Timer Control Speed Slide Control Optional Damper Roof Cap Duct 6 8 9 12 13 15 13 15 16 17 18 19 Page ID Product Important It is recommended that all electrical equipment be tested prior to installation 4 I F A H H E D C B Power Source Run for Optional Expansion Vent Lights Optional Accessible Area Bath Area Exterior Roof ...

Страница 5: ...electrical equipment be tested prior to installation 5 G A H D C Power Source Run for Optional Expansion Vent Lights Accessible Area Exterior Wall Bath Area A B C D E G H Fan Expansion Vent Electronic Timer Control Speed Slide Control Optional Damper Wall Vent Duct 6 8 9 12 13 15 13 15 16 17 18 19 Page ID Product H E B ...

Страница 6: ...et Thermal Overload Protection Speed Control 100 Speed Controllable Testing U L Listed CSA Certified Airstream Tolerance Suitable for Airstream Temperatures up to 140 F Dimensions 9 1 2 Diameter x 10 Length 1 Mounting Bracket 2 Vibration Isolation Grommet 3 1 Screws 4 7 16 Screws 5 Stud Ceiling Joist Stud Ceiling Joist 1 Screw 4 Mounting Bracket 2 Vibration Isolation Grommet 3 100 CFM Fan 1 7 16 S...

Страница 7: ...ation operation and maintenance Caution For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors Note All wiring must be done in accordance with National Electrical Code and local building code Note The combustion air flow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer ...

Страница 8: ...eplace the fan terminal box cover All fan motor and capacitor connections have been pre wired from the factory No additional fan wiring is necessary 6 Using the 1 wood screws 4 provided attach the fan mounting bracket 2 to a support beam at the selected location see figure 1 on page 6 Note Fan 1 mounting can be at any point along the duct and in any angle however vertical mounting is recommended t...

Страница 9: ...n Lumens 470 Color Temperature 3000K Warning For your safety read and understand instructions completely before starting Before wiring to power supply turn off electricity at the fuse or circuit breaker box Make sure electrical service to fan is locked in OFF position Note Prior to installation consider the placement of the Expansion Vent carefully taking into account the location of electrical pl...

Страница 10: ...tom edge of joist Halogen Light LED Light B B Anti slide locking screw Figure 1 Figure 2 1 Expansion Vent Housing 1 Expansion Vent Housing 3 Expansion Vent Hanger Bars Screws LED Light Install 2 Expansion Vent Grille Figure 5 Halogen Light Install 6 Cutout Ceiling Material B Figure 4 1 Expansion Vent Housing 2 Expansion Vent Grille 6 Cutout Ceiling Material B 1 Expansion Vent Housing No Light Inst...

Страница 11: ...n anti slide screws to keep hanger bars 3 in place see figure 2 on page 10 Note Expansion vent hanger bars 3 can be used on ceiling joists up to 24 on center Note If ceiling material is thicker than 5 8 the locator tabs may be removed to allow the grille collar to be flush with the finished ceiling material Note Designed for 1 1 8 ceiling material maximum 4 5 Cut a 6 round hole for the expansion v...

Страница 12: ... Halogen Bulb Install LED Bulb Install Insert Bulb into Socket Twist to Secure Insert Bulb into Socket Twist repeatedly to Secure 7 Install the bulb by gently inserting it into the socket in the expansion vent housing 1 Install the expansion vent grille 2 by pushing it firmly into the steel collar until it is shouldered by the ceiling material see figure 8 for halogen figure 9 for LED ...

Страница 13: ...t 90m Note Use these devices with copper or copper clad wire only Note When combinations of electronic time control slide speed control are installed in a ganged wall or outlet box derating is required When two devices are mounted in a ganged box the maxminum load per device shall not exceed 4A or 500 watts When three or more devices are mounted in a ganged box the maximum load shall not exceed 3A...

Страница 14: ...n Wiring Timer Light Fan Wiring Hot Black Neutral White Black Black White White Black White Red Black Fan Vent Lights Timer Slider Fan Wiring Hot Black Neutral White Black Black White White Red Black Fan Timer Lights Slider Fan Wiring Hot Black Neutral White Black Black White White Black White Red Black Fan Vent Lights Green Ground Green Ground Green Ground Green Ground Green Ground C C C C D D B ...

Страница 15: ...he tabs to release With desired faceplate line up tabs and press in sides one at a time to attach Remove pre cut 3 8 of insulation from each circuit conductor Make sure the ends of wires are straight Install electronic time control 1 and slide speed control 2 into double gang box two single gang boxes or single gang box as installation permits Connect wires per applicable wiring diagram on previou...

Страница 16: ...Screw 2 Installation Specifications Note Output end should never be lower than input Note Follow all applicable codes and standards Installation Considerations Please read this manual in its entirety prior to installation Label must be upright Screw Damper Input to Expansion Vent Housing Figure 1 Damper Expansion Vent 1 Figure 2 B E Input Output Install with this label up Output end should never b...

Страница 17: ... and standards Installation Considerations Please read this manual in its entirety prior to installation F G A A H H Roof Cap 1 Roof Cap Composition Galvanized Steel Rough in Cutout 4 1 8 Duct Connection 4 Cap Dimensions 8 1 4 L x 6 1 4 W x 4 1 4 H Grille Composition Plastic Extension Composition Galvanized Steel Rough in Cutout 4 1 8 Duct Connection 4 Cap Dimensions 6 L x 6 W x 7 16 H Duct Extens...

Страница 18: ... 1 12 Gallon Mastic Tube 4 100 CFM Fan Exhaust to Roof Cap or Wall Vent Damper 4 Expansion Vent Flex Duct Tie 36 Flex Duct Tie 18 2 Flex Duct 4 x 25 1 3 Figure 1 Figure 2 Pull back outer cover and insulation Pull outer cover and insulation to completely cover the fitting Apply Mastic 4 over fitting and or inside the inner liner Pull inner liner at least 1 over fitting Secure inner liner to fitting...

Страница 19: ...t of support spacing is permissible Vertically installed duct shall be stablized by support straps at a maximum of 6 on center Note Do not use on oval collars for medium or high pressure Warning Insulated flexible duct contains fiber glass wool which has been classified as a possible cancer hazard by inhalation Fiber glass wool may cause temporary irritation to skin eyes and respiratory tract Note...

Отзывы: