background image

SR2400 – SR4803 - SR6000

User's Manual

___________________________________________________________________________________________________________________________________________________ 

EAGLETRONIC MTL2

SR2400, SR4803, SR6000 

USER'S MANUAL

V2.1 – May 2006

www.eagletronicchargers.com

__________________________________________________________________________________________________________________________________________________

Page 1/18

Содержание EAGLETRONIC MTL2 Series

Страница 1: ..._________________________________________________________________ EAGLETRONIC MTL2 SR2400 SR4803 SR6000 USER S MANUAL V2 1 May 2006 www eagletronicchargers com ________________________________________...

Страница 2: ...ARGER 6 AC INPUT CONNECTION 7 AC INPUT VOLTAGE SELECTION 208 240 480VAC ONLY FOR SR4803 7 AC INPUT VOLTAGE SETTINGS 8 4 HOW TO USE THE CHARGER 10 PROGRAMMATION OF THE GASSING POINT 10 BATTERY CONNECTI...

Страница 3: ...in damp area without being extremely careful Stand on dry rubber mat or dry wood and use insulating gloves when dampness or sweat cannot be avoided Keep clothing dry INSTALLATION AND GROUNDING A power...

Страница 4: ...de an adequate amount of fresh air for the number of batteries being charged This is essential to prevent an explosion Always keep sparks flames burning cigarettes and other sources of ignition away f...

Страница 5: ...grammation by DIP switches Programmable Gassing Voltage Proportional Algorithm for charge time calculation Programmable Equalize System Automatic Pulsed Manual Automatic voltage controlled maintenance...

Страница 6: ..._____________ Page 6 18 CAUTION Risk of electrical shock The charger can be installed by qualified personnel only To prevent fire or shock hazard do not expose the unit to rain or moisture Don t use t...

Страница 7: ...ECTION 208 240 480VAC ONLY FOR SR4803 The model SR4803 can be configured for 208 240 VAC or 480 VAC nominal input voltage This selection can be made with the 220 240 480 VAC SELECTION BOARD that is lo...

Страница 8: ...R2400 singlephase if the measured voltage is 212 VAC the transformer should be connected to the tap number 4 that corresponds to 208 VAC Example 2 for a charger SR6000 threephase if the measured volta...

Страница 9: ...____________________________________________________________________________________ Singlephase units SR2400 Threephase units SR4803 SR6000 ___________________________________________________________...

Страница 10: ...tsink see next picture The dipswitch unit has 4 switches the two central switches number 2 and number 3 are used for the programmation of the gassing point To modify the value follow these steps Disco...

Страница 11: ...________________________________________________________________________________________________________________ _______________________________________________________________________________________...

Страница 12: ...f the battery voltage is higher than the maximum threshold of 2 60 V cell the charger doesn t start and the display will show the flashing error message Voltage High If the voltage of the battery is b...

Страница 13: ...rge cycle these parameters are displayed in sequence as indicated in the picture The letter U A C h indicates which parameter being is displayed To display the time the charger uses this format HOURS...

Страница 14: ...SAFETY TIMER EMERGENCY STOP If the battery doesn t reach the gassing voltage within 12 hours the charge is terminated by the safety timer and the display shows the error message Time Error If this err...

Страница 15: ...n when the user picks up a forklift he will always chose the one with highest he time elapsed after charge termination The final values of Voltage cell time of charge and capacity charged remain store...

Страница 16: ...he manual equalize has been selected the only way to deselect it is to disconnect and re connect the battery DAILY EQUALIZE The DAILY EQUALIZE function will extend all the charge cycles by 4 hours and...

Страница 17: ...by the indication of the charge current REFRESH OPERATION If a battery is not used for a long time example seasonal works holiday periods it should be kept well charged to avoid a reduction of perform...

Страница 18: ...n and the self discharge is significant the refresh charge will be often activated and the battery will be kept charged without problems les are completed the charger passes to REFRESH mode MANUAL CHA...

Страница 19: ...01 2 1301 4 05 05 6...

Страница 20: ...0 120 3 2412 5 16 16...

Страница 21: ...0 0 1 2 3 45 6 6 7 8 3 9 3...

Страница 22: ...0 1 2 3 4 3 4 3 4 5 5 5 6 6 5 6 5 7 8 8 6 3 4 6...

Страница 23: ...____________________________________________ Bassi Bruno elettromeccanica C S n c Via Mensa 3 2 48020 S Maria in Fabriago Lugo RA Tel 39 0545 995008 Fax 39 0545 995006 info batterychargers it ________...