
Configuring the Camera
4-22
BASLER L800
k
Draft
Left Odd/Even Gain Balance CSR
Note:
The left odd/even gain balance can be set by writing a floating point value to the Absolute
L O/E Gain Balance field or by writing an integer value to the Raw L O/E Gain Balance field. Refer
to Section
for an explanation of the difference between these two fields.
Register Base Address:
0x0E40
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control register:
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
Field Name:
Absolute L O/E Gain Balance
Offset:
0x0001
Size:
4 Bytes
Type:
Read / Write
Description:
Writing a floating point value to this field to sets the left odd/even gain balance in dB. For
example, if the value in this field is set to +0.55, the left odd/even gain balance would be
+0.55 dB.
The left odd/even gain balance can normally range from -1.00 dB to +1.00 dB in increments
of 0.01.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
See Section
for more information about gain balance.
Field Name:
Absolute Min
Offset:
0x0005
Size:
4 Bytes
Type:
Read only
Description:
Minimum allowed floating point value for the absolute left odd/even gain balance setting.
The value in this field is a standard IEEE-754 single precision (32 bit) floating point number.
Field Name:
Absolute Max
Offset:
0x0009
Size:
4 Bytes
Type:
Read only
Description:
Maximum allowed floating point value for the absolute left odd/even gain balance setting.
Field Name:
Raw L O/E Gain Balance
Offset:
0x000D
Size:
2 Bytes
Type:
Read / Write
Description:
Writing an integer value to this field sets the left odd/even gain balance.
The value can normally range from 228 (0x00E4) to 288 (0x0120).
The dB of left odd/even gain balance that the camera will apply at a given setting in this
field is determined by this formula:
dB = 20 x log ( raw setting / 256 )
For example, if the value in this field is set to 270 (0x00F0), then:
dB = 20 x log (270 / 256)
dB = +0.46
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the raw value
Byte 2 = High byte of the raw value
See Section
for more information about gain balance.
Содержание L800k
Страница 4: ......
Страница 10: ...Contents VI BASLER L800k Draft...
Страница 23: ...Camera Interface BASLER L800k 2 7 Draft Figure 2 3 Camera Frame Grabber Interface...
Страница 40: ...Camera Interface 2 24 BASLER L800k Draft...
Страница 152: ...Mechanical Considerations 5 6 BASLER L800k Draft...
Страница 166: ...Feedback iv BASLER L800k Draft...