Configuring the Camera
4-52
BASLER A640
f
DRAFT
Register Name:
Strobe 0 Control
Offset from Base Address:
0x200
Field
Bit
Description
Presence Inq
0
Indicates the presence of the Strobe 0 signal control feature.
0 = not available 1 = available
The Strobe 0 control feature is available on all A640f cameras.
This field is read only.
---
1 ... 5
Reserved
On / Off
6
Sets whether the Strobe 0 signal is on or off.
0 = off 1 = on
Default = 0 on all A640f cameras
If this bit is 0, all other fields in this register are read only.
Signal Polarity
7
Sets the polarity of the Strobe 0 signal.
0 = low active 1 = high active
Default = 1 on all A640f cameras
Delay Value
8 ... 19
Sets the delay value for the Strobe 0 signal (see Section
). The de-
lay value can range from 0 to 4095.
Strobe 0 Delay = (Delay Value Setting) x (1/1024 ms)
Default = 0 on all A640f cameras
Duration Value
20 ... 31
Sets the duration value for the Strobe 0 signal. The duration value can
range from 0 to 4095.
Strobe 0 Duration = (Dur. Value Setting) x (1/1024 ms)
Default = 4095 on all A640f cameras
Register Name:
Strobe 1 Control
Offset from Base Address:
0x204
Field
Bit
Description
Same definitions and values as Strobe 0 Control.
Содержание A640F
Страница 1: ...USER S MANUAL Document Number DA00073201 Release Date 1 June 2005...
Страница 4: ......
Страница 14: ...Introduction 1 6 BASLER A640f DRAFT...
Страница 20: ...Camera Interface 2 6 BASLER A640f DRAFT Figure 2 3 I O Schematic...
Страница 163: ...Smart Features BASLER A640f 6 27 DRAFT Figure 6 6 Sample Text File for Use With Upload Button...
Страница 180: ...Technical Support 8 2 BASLER A640f DRAFT...
Страница 184: ...Revision History ii BASLER A640f DRAFT...
Страница 186: ...Feedback iv BASLER A640f DRAFT...