Configuring the Camera
BASLER A102
k
4-19
DRAFT
4.2.4.14 Gamma Correction
Purpose:
To enable or disable gamma correction. See Section
for an explanation of gamma
correction.
Type:
This is a read or write command.
Read Command:
Cmd-ID
R/W-Flag
Data Length
Data
0xC5
1
1
-
Response:
Cmd-ID
R/W-Flag
Data Length
Data
0xC5
0
1
1 Byte
Write Command:
Cmd-ID
R/W-Flag
Data Length
Data
0xC5
0
1
1 Byte
Response:
None
Data Format:
Byte 1
An ID that specifies the gamma correction status
(see the table below).
ID
Digital Shift
0x00
Gamma = 1.0 (no correction - feature disabled)
0x01
Gamma = 1.2
0x02
Gamma = 1.4
0x03
Gamma = 1.5
0x04
Gamma = 1.8
0x05
Gamma = 2.0
0x06
Gamma = 2.2
0x07
Gamma = 2.4
0x08
Gamma = 2.6
0x09
Gamma = 2.8