Cycle and Control Value Programming
5.2.5 Modifying Cycle
Parameters
It is possible to modify a preprogrammed or a customized cycle to
adjust to Customer needs. See
Table 5-1
, C
YCLE
D
ESCRIPTION
C
HART
,
for default values and treatment parameters.
NOTE: When modifying cycle parameters, take note of the
following:
1) Modifications must be done treatment by treatment in a
sequential order.
2) Left and right arrow touch pads allow scrolling through current
treatment parameters.
3) Numeric key pads appear when a numeric entry is necessary.
4) Press
ENTER
in numeric keyboard to confirm entry.
5) Pressing
X
touch pad allows to cancel modification of current
treatment and returns to change cycle screen. Parameter can
be changed by pressing corresponding touch pad.
6) Once all modifications to a treatment have been made, press
OK
touch pad to save modifications and advance to next
treatment.
1.
Enter Supervisor Mode as explained in
2.
Follow Modifying a Cycle sequence until screen shows Change
Cycle screen.
3.
Press
CHANGE CYCLE PARAMETERS
touch pad, Miscella-
neous screen appears.
NOTE: There are three Miscellaneous screens, according to
options selected.
4.
Press
OK
button. Screen advances to the first cycle treatment.
5.
Once modifications to treatment are finished, screen advances
to next treatment available.
Touch pads on screens appear according to parameter to be
modified:
•
Duration
touch pad – to modify or establish treatment dura-
tion time, in minutes and/or seconds.
•
Temperature
touch pad – to select treatment water tempera-
ture (showed in C or F, according to setting).
•
Injection Rate
touch pad – every time touch pad is pressed
injection rate is increased by 1 ml [1/8 oz/gal].
•
Tank
touch pad – to select Alkaline (tank 1) or Acid (tank 3)
tank to be used in treatment. Once tank is selected press
RIGHT
arrow to establish Drain Percentage Saved.
•
Temperature Guaranteed
touch pad – to establish Yes or
No Water temperature must be guaranteed.