Installation / Assembly
dizzer® XL Series Modules for Open Platform
– Assembly Instructions 1.1(2019-01) E inge
Page 27 of 44
© inge GmbH
5.2.2
Tools
NOTE
CAUTION, PROPERTY DAMAGE!
If the tightening torques specified in these instructions are
exceeded, the system parts may become damaged and leaks may
occur during operation.
Always adhere to the specified tightening torques!
NOTE
The 2’’ composite couplings should be tightened until the contact
surfaces of both coupling halves are flush and resting against each
other without a gap. These types of couplings do not require a
specific torque. The usual range of torque for the 2’’ coupling is 10-
15 Nm.
Only the following tools and devices are approved for the installation of dizzer
®
XL Series Modules:
Open-end or box wrench (size 17)
Torque wrench for hexagon socket (size 8)
Spirit level 2000 mm
Spirit level 600 mm
5.2.3
Preparation of gaskets and O-rings
Do not use silicone or any lubricants or sealants that contain silicone during assembly. Only glycerin may be
used as a lubricant for gaskets, o-rings, couplings etc. (with a purity of > 99.7 %).
NOTE
USE DISPOSABLE GLOVES!
Use disposable gloves to apply lubricant to the couplings and
gaskets.