background image

Operations

Testing Operation:

( 1 ) Press the power button to turn unit on. “FEI” will appear on the screen. After 3 seconds the

record number will appear with a reading of “0.0”. If 0.0 is not displayed press ZERO to clear max-

imum reading or the down arrow (3) to advance to the next record. After re-use of this instrument,

the screen displays the record and corresponding data of the record at time unit was shut-off.

( 2 ) Squeeze the top (8) and bottom (10) metal pads with your finger(s) and/or thumb. The dis-

play reading will go up as your pinch force increases. It will record the maximum force exerted

for the current record.

( 3 ) Press down button 

▼ (3) 

to save the current record and advance to the next record. Press

up button 

▲ (2) 

to save the current record and move to the previous record.

( 4 ) To toggle between pounds and kilograms: press and hold up button (2) for 3 seconds. Press

up button (2) again to toggle. To save the unit selection turn the unit off and back on. The selected

unit of measurement will be the default next time the unit is rebooted.

( 5 ) Press ZERO (4) button to clear current record and set the current record to 0.0.

( 6 ) Press power button (1) to shut unit off.

Query (result recall) Operation:

( 1 ) Press up button 

▲ (2) 

to browse the last record or down button 

(3) to browse the next

record.

Battery Replacement

When the screen displays “LO” the battery should be replaced. Battery replacement steps:

1. Slide the battery cover (11) off by placing your thumb on the cover and sliding down.

2. Remove the battery by pushing the metal clip towards the outside.

3. Insert the battery with the + facing outside. The battery should “click” into place.

4. Slide battery cover (11) into place to cover battery compartment.

Cleaning

Turn off unit before cleaning. Clean outside of unit with soap and water or disinfectant solution,

then dry. Unit must be dry before it is turned on. Do not submerge unit into liquid.

CAUTION

Keep the instrument out of water, oil and other liquids.

This is a precision measuring device. Handle with care. Do not drop or throw.

Do not dis-assemble unit.

Make sure unit is turned off before removing battery or cleaning.

Отзывы: