FWG09I Assembly instructions
9
Service menu
Activation
Briefly press the buttons “
Menu
” and ”
” simultaneously
⇒
FWG09 responds “
Service on,
object number
<Object>
, car
<Car>
” and refers to some technical information. You can exit the
service menu again at any time in the same way.
The “
Menu
” button can be used to browse through the individual menu items. The settings can be
changed with the buttons “
” and “
Option-
“.
When you leave the service menu, the unit remembers the settings that were previously selected
and responds with “
Service off
”.
Menu structure
Alarm button one is...
NO contact.
Cable break monitored.
NC contact.
Alarm button two is…
NO contact.
Cable break monitored.
NC contact.
Misuse is...
Off (default) – the misused alarm is reported as a normal alarm.
On – misused alarm is reported as such.
Suppressed – misused alarm is not reported at all.
Fire alarm – As long as voltage is supplied, an announcement is played to leave the lift
because of a fire.
Battery broken – If voltage is present the pictograms start blinking according to EN81-28.
Battery broken inverted – The pictograms start blinking if the misuse input is not active.
Malfunction warning – A message is sent to the call center.
Volume is...
The volume of the loudspeaker of the reassurance announcement and voice communication when
triggered via alarm button 1 can be set here.
Internal Speaker is…
On (default) – Both speakers are active.
Off – Only the external speaker is used for alarm.
The internal loudspeaker can be switched off. In the event of an emergency call only the external
loudspeaker is used. If no external speaker is connected, the device will remain silent in the event of
an alarm!