background image

BASE

LV-8RCL-N

Low Voltage

Power Distribution Module

Installation and Operation Manual

BASE Electronics, Inc.

2856-C Janitell Road  •  Colorado Springs, CO 80906  •  (719) 540-9697  •  Fax (719) 540-9698

Figure 1 - LV-8RCL-N Wiring Diagram

BASE Electronics, Inc.

2856-C Janitell Road  •  Colorado Springs, CO 80906  •  (719) 540-9697  •  Fax (719) 540-9698

Limited Warranty

The LV-8RCL-N Low Voltage Power Distribution Module is warranted by BASE Electronics against 

manufacturing defects in materials and workmanship for a period of 2 years from date of purchase. Dur-

ing this period, any warranty repair required will be made at no charge for parts or labor. This warranty 

does not apply to any work or materials provided by any outside persons or technicians involved in the 

installation, unauthorized repair, connection, or testing of this product. This warranty does not cover any 

damage or failure caused by or attributable to Acts of God, abuse, misuse, improper or abnormal usage, 

faulty or improper installation or maintenance, neglect or accident. BASE Electronics is not responsible 

or liable for any special, consequential or indirect damages resulting from or in connection with the use 

or performance of this product as pertaining to economic loss, property loss, costs for removal or instal-

lation, or loss of revenues or profit. Except as provided herein, BASE Electronics makes no expressed 

or implied warranties. The duration of product performance for its intended purpose is limited to the 

duration set forth herein.

For Warranty or other repair, send the product postage prepaid to BASE Electronics and include Sender’s 

name, company, address, phone and brief problem description. BASE Electronics will notify sender of any 

required repair costs not covered under this warranty prior to making such repairs.

This Warranty gives you specific legal rights.  You may have other rights that vary from state to state.

Figure 2 - LV-8RCL-N Schematic Diagram

LV-8RCL-N Specifications

• Indoor Temperature Range: -25° C. to +70°C.

• Electrical

Maximum Voltage AC/DC: 30V

Maximum Total Current: 8A

Maximum Recommended Current per Output: 2.5A

Maximum Total Relay Coil Current Draw: 1A

Connections: Captive Screw Terminals for #14 to #22AWG Wire

• Size: 5.00” wide by 8.00” long by 2.50 maximum height (inches) with relays installed.

• Mounting: (4) 3/8 inch high nylon standoffs included

• Indicators, Controls and Jumpers

Red LED Indicators at all 9 relay positions

Common Power - and +, Cut = Separate Relay Control Power, Uncut = Common Power

Mode Jumpers Uncut = 8 Continuous, Cut 8D = w/Disconnect, Cut 4x4 = 4x4 Mode

• Special Features

Mode Jumpers, 4x4 Mode

Power Disconnect Relay Socket with Auxiliary Contact Terminals

8 Output Isolation Relays with LED Indicators

© Copyright 2022 - BASE Electronics, Inc.

CP

8

8NC

8NO

Com

F

1

OUTPUTS

CONTROLS

CONTROL

FUSE

DISCONNECT

RELAY

-

+

ST

NC

DC

NO

-

+

PWR

CTL

LOCK

8D

4x4

5

5NC

5NO

Com

4

4NC

4NO

Com

1NC

1NO

Com

OUTPUTS

1

2

3

4

5

6

7

8

1

2

3

4

5

6

7

8

LOW VOLTAGE POWER

DISTRIBUTION MODULE

LV-8RCL-N

C

CONTROLS

DISC

RELAY

COM PWR

JUMPERS

8  D

4X4

- PWR +

- CTL +

ST     Com    NO     NC

1

2

3

4

5

6

7

8

NC

Com

NO

NC

Com

NO

NC

Com

NO

NC

Com

NO

NC

Com

NO

NC

Com

NO

NC

Com

NO

NC

Com

NO

F

+

-

INPUT MAX.

30VAC/DC  8A  60Hz

CONTROL FUSE

1.0 A MAX.

OUTPUTS 1 - 8 MAXIMUM FUSE SIZE 2.5

A

W

ARNING -

 T

o reduce the risk of fire, replace only with same type and rating of fuse.

w w w . b a s e e l e c t r o n i c s . c o m

BASE

Access Control

Panel Contact

Door Release

Pushbutton

Electric

Lock

Electric

Strike

From

Lock

Power

Supply

From

Relay

Power

Supply

Normally Closed

Dry Contacts of

Fire Alarm Panel

Write Fuse Size Here

Open Collector

Transistor Output

(Sink Output)

DC Com

Output (Collector)

Отзывы: