BASE
Micro-Series
Features
• Distributes Door Lock Power to 8 Fused or PTC Outputs
• Outputs directly controlled by Access Control System
• Fail-Safe or Fail-Secure selectable per Output
• FACP Interface for Emergency Power Disconnect
• Replaceable Disconnect Relay with Aux Contact
• Small Footprint PCB - 3.0”w x 6.0”h
• Includes Mounting Hardware
DAC8 / DAC8R
Direct Access Controller
DAC8
DAC8R
Includes (8) 2.0 A replaceable fuses, standard 3AG (¼” x 1 ¼”)
Includes (8) 2.5 A PTC auto-resettable fuses
Install in accordance with all applicable sections of the National Electrical Code and other State or Local Regulations.
BASE Electronics, Inc.
• 2856-C Janitell Road • Colorado Springs, CO 80906 • (719) 540-9697 Fax (719) 540-9698
www.baseelectronics.com
INSTALLATION
Locate the unit inside a UL Listed enclosure, such as a BASE
LVPC Power Cabinet or Econo•
Box,
close to the source pow-
er supply. Drill or punch (4) 0.187” diameter holes (3/16) to
match the (4) corner holes in the printed circuit board. Push the
nylon standoffs supplied into each hole and snap the module
into place.
POWER SUPPLY WIRING
Common Power Supply for Outputs and Disc Relay Control
Do not cut Common Power Jumpers. Connect 12 or 24VDC
power supply input leads to the
MAIN POWER
input terminals
at the lower right side of the module. See Power Input Wiring
Diagram 1.
Separate Power Supplies for Outputs and Disc Relay Control
Cut both Common Power Jumpers. Connect 12 or 24VDC Re-
lay Control power supply input leads to the
DIS RLY POWER
input terminals at the lower right side of the module.
Connect 12-24VAC/DC Door Lock power supply input leads
to the
MAIN POWER
input terminals at the lower right side of
the module. See Power Input Wiring Diagram 2.
Installation and Operations Manual
WARNING
Turn off all power feeding the module terminals before servicing or changing input/output
wiring, removing or replacing fuses, etc. Failure to observe this warning may cause electrical shock hazard or
may damage internal or external circuit components.
!
C
+
-
+
-
MAIN POWE
R
DIS RL
Y
POWE
R
COMMON
POWER
JUMPERS
+
-
Power Input Wiring Diagram 1
Common Power for
Door Locks and Relay Control
12 or 24VDC
12 or 24VDC
+
-
C
+
-
+
-
MAIN POWE
R
DIS RL
Y
POWE
R
COMMON
POWER
JUMPERS
+
-
Power Input Wiring Diagram 2
Separate Power for
Door Locks and Relay Control
12 - 24VAC or DC
+
-
leave jumpers intact
cut both jumpers
12 or 24VDC
+
-
Use minimum of
18AWG conductors.
Use minimum of
18AWG conductors.
Page 1 of 4
Note: Disconnect and Aux Relays are supplied with the
Module and must match Relay Power voltage used - specify
voltage when ordering. See Models - Page 4.
Note: Disconnect and Aux Relays are supplied with the
Module and must match Main Power voltage used - specify
voltage when ordering. See Models - Page 4.