Configuration trough web interface
–
24
Common settings
Master card: Master card number.
Use master code: Enable/disable using master code to open the lock.
Master code: The code entered on the keypad for opening the lock.
Locks management
When using the control module with two locks SH-42, when entering the master code
on the panel, both locks will open.
Registering access cards via web interface
Enter 0 in the “Master Card” field and click the “Apply” button.
Next, bring the master card, necessary for registration, to the panel reader area - the
text message "Admin Key" will be displayed and the signal "BEEP" will sound, which
means that the master card has been successfully registered.
After that, in the area of the panel reader hold the user cards in turn. After each user
card, the “BIP” signal will sound, which means the successful registration of the raised
card. Also, the panel display shows that a new card has been added.
The time between adding cards should not exceed 10 seconds.