background image

 

Installation Instructions 

22 / 32   

 

 

 

1583011 

EN 

Reception and Operation Control 

When the appliance is installed, but before commissioning it to the user, check the 
appliance for the following points: 

–  if the entire protective film was carefully removed from all external 

surfaces; 

–  if all connections were executed pursuant to this installation instruction;  
–  if all standards and safety regulations, legal acts and recommendations 

in force have been observed and met;  

–  if gas connection is tight; 
–  if gas available in the installation location, its type and pressure, are 

concurrent with the data provided in type plate. Otherwise, re-fit or adjust 
the appliance following instructions in section 

'Switching to Different 

Gas Type'

–  if the right nozzles are installed. To this end, check the nozzle table and 

make sure that the installed nozzles are concurrent with the data. You 
may perform a volumetric gas flow measurement for the purpose of 
additional check. To this end, start the gas burner, and after approx. 10 
minutes (in operating mode) use a gas meter to check if the measured 
flow (in m3/h or kg/h) is concurrent with data in nozzle table.  

 
Following installation, the installation technician must: 

–  explain the functions and correct usage and application of the appliance 

to the user; 

–  inform the user that any structural changes that may affect air inflow for 

the purpose of burning require additional checking of the appliance's 
operation and tightness. 

 
Prepare and fill in completely the reception protocol and submit it to the client for 
signing.  

To end with, start the appliance in order to check its operation, following indications 
in section 

'Igniting Gas Burner'

 and check: 

–  Ignition of burners 
–  Uniform shape of the flame (the flame must be blueish, without yellow 

tips and burn uniformly at its base)  

 

ATTENTION! 

If the shape of the flame features yellow smudges, it means that primary 
air is not set correctly. If the primary air flux is too high, the flame is short 
and it features tendency to detach from the burner. Check the flame also 

Содержание Flex 7360

Страница 1: ...Flex 7360 1583011...

Страница 2: ...scher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Service hotline 49 5258 971 197 www bartscher com 1312CR6138 Version 1 0 Date of preparation 2021 06 1...

Страница 3: ...port Packaging and Storage 8 3 1 Delivery Check 8 3 2 Packaging 8 3 3 Storage 8 4 Technical Data 9 4 1 Technical Specifications 9 4 2 Functions of the Appliance 13 4 3 List of Components of the Applia...

Страница 4: ...s included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the area the...

Страница 5: ...ent Too high a mains voltage or incorrect installation may cause electric shock The appliance may be connected only if data on the rating plate correspond with the mains voltage To avoid short circuit...

Страница 6: ...on WARNING Danger of suffocating and explosion due to leaking gas When you sense gas odour observe the following rules immediately close the gas control knob s and the main gas valve provide for suffi...

Страница 7: ...ture remains for some time after switching the appliance off Do not touch any hot surfaces of the appliance Use the provided handling elements and holders You may transport and clean the appliance aft...

Страница 8: ...from its intended standard use is prohibited and considered to be an unintended use The following is an intended use Preparation of food baking cooking stewing frying etc in professional kitchens e g...

Страница 9: ...ntroduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2 Copyrig...

Страница 10: ...used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Particularly...

Страница 11: ...ss steel Oven dimensions W x D x H in mm 635 x 363 x 3520 Oven volume in litres 80 Temperature range min max in C 50 270 Gastronorm 1 1 GN Number of guide rail pairs 4 Distance between guide rail pair...

Страница 12: ...ded Gas burner single ring burner Ignition type manual ignition Pilot flame yes Oven type electric Oven function air circulation Oven characteristics single circuit heater Fume extractor yes Base type...

Страница 13: ...MK II2E3B P 20 30 mbar NL RO II2LL3B P 20 050 mbar DE II2HS3B P 25 30 mbar HU I3B P 30 mbar MT IS II2EK3B P 25 30 mbar NL Table 1 Characteristics of burners and nozzles Category P mbar G20 G25 G30 31...

Страница 14: ...0 31 II2H3B P II2E3B P 20 30 MAX 1 40 G20 0 90 G30 31 1 85 G20 1 20 G30 31 0 40 G20 0 21 G30 31 MIN REG G20 0 50 G30 31 REG G20 0 60 G30 31 H mm 8 00 G20 9 00 G30 31 3 00 G20 8 00 G30 31 II2LL3B P 20...

Страница 15: ...9 00 G30 31 2 00 G25 8 00 G30 31 II2L3B P 20 G25 30 MAX 1 55 G25 0 90 G30 31 2 00 G25 1 20 G30 31 0 40 G20 0 21 G30 31 MIN REG G25 0 50 G30 31 REG G25 0 60 G30 31 H mm 4 00 G25 9 00 G30 31 2 00 G25 8...

Страница 16: ...ware is not part of the delivery Fig 1 1 Burner 6 pcs 2 Sliding grates 3 pcs 3 Fume extractor 4 Hob 5 Control panel 6 Open base structure 7 Height adjustable feet 4 pcs 8 Oven door handle 9 Oven door...

Страница 17: ...t prevention acts in force Fire prevention provisions Respective IEC provisions DVGW G600 TRGI Technical regulations for gas installations TRF Technical regulations for liquid gas Directive and regula...

Страница 18: ...g package materials for instance plastic bags and EPS If the appliance is covered with a protective film remove it Remove the film slowly so no glue residues are left Remove any glue residues with the...

Страница 19: ...ction Electrical connection of the appliance to mains power supply must be executed by a qualified electrician according to international national and local regulations in force Before connecting the...

Страница 20: ...rce and properly installed The connection may be established as fixed or detachable if flexible tubes are used they must be made of stainless steel pursuant to DIN 3383 Part 1 or 3384 If threaded conn...

Страница 21: ...current with the provided values notify the gas supplier and do not operate the appliance until the cause is clarified and removed Use a u pipe manometer to measure pressure at least 0 1 mbar resoluti...

Страница 22: ...dles 3 Undo fastening screw of a nozzle handle 4 Replace the existing nozzle to a nozzle that is suitable to a given gas type see MAX data for nozzles in Table 2 Characteristics of Burners and Nozzles...

Страница 23: ...ckwise until the required flame intensity is obtained if natural gas was changed to liquid gas use a small flat screwdriver to rotate a small setting screw clockwise until the required flame intensity...

Страница 24: ...the purpose of additional check To this end start the gas burner and after approx 10 minutes in operating mode use a gas meter to check if the measured flow in m3 h or kg h is concurrent with data in...

Страница 25: ...the connection box is properly mounted Preparation of the Appliance 1 Using a suitable cleaning agent remove anti corrosive coating from all surfaces of the appliance 2 Before the first start up the f...

Страница 26: ...ont left hob gas controller 9 Rear left hob gas controller Warning Indications WARNING Risk of burns During operation the housing burners sliding grates and oven door become very hot and remain hot fo...

Страница 27: ...ssed in counter clockwise to a position marked with MIN 5 Ignite the flame with a lighter or a match 6 After igniting keep the gas controller pressed for 10 seconds in order to heat up the thermo elem...

Страница 28: ...sing is put after pre heating 2 Switch the oven on with the ON OFF switch The green operation control light in the ON OFF switch will light up and will be lit through the entire operating period of th...

Страница 29: ...e air is evenly distributed inside the oven The ring heater switches itself on automatically through operation of the temperature controller Switching Oven Off 1 If the oven is not to be used any more...

Страница 30: ...ance or surface damage For cleaning stainless steel surfaces housing hobs sliding grate oven door guide rails and rack use special cleaning agents for stainless steel only When using steel wool steel...

Страница 31: ...eaning agent s manufacturer 3 Wipe the cleaned surfaces thoroughly with a cloth soaked in fresh water and make sure there are no cleaning agent residues left 4 To end with dry the cleaned surfaces and...

Страница 32: ...s verification of all connections power gas verification of appliance operation We recommend to replace worn elements during maintenance to avoid further service works and sudden failures of the appli...

Отзывы: