background image

 

 

 

 

 

 

 

Silversteam 5230M - 5111M - 

7111M - 10111M  

 

 

 

 

116622 - 116726 - 116728 - 116731 

 

 

 

Содержание 116726

Страница 1: ...Silversteam 5230M 5111M 7111M 10111M 116622 116726 116728 116731...

Страница 2: ...scher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Technical Support Hotline 49 5258 971 197 www bartscher com Version 1 0 Date of preparation 2021 12 20...

Страница 3: ...ivery Check 8 3 2 Packaging 8 3 3 Storage 8 4 Technical Data 9 4 1 Technical Specifications 10 4 2 Functions of the Appliance 14 4 3 List of Components of the Appliance 15 5 Installation Instructions...

Страница 4: ...s included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the area the...

Страница 5: ...nt Too high a mains voltage or incorrect installation may cause electric shock The appliance may be connected only if data on the rating plate correspond with the mains voltage To avoid short circuit...

Страница 6: ...hazard clean the appliance regularly Do not cover the appliance with e g aluminium foil or cloths Use the appliance only with materials designated to this end and with correct temperature settings Mat...

Страница 7: ...ith limited physical sensory or mental capabilities nor by persons with limited experience and or limited knowledge Children should be supervised to ensure that they are not playing with or switching...

Страница 8: ...dard use is prohibited and considered to be an unintended use The following is an intended use Preparation of suitable food 1 4 Unintended Use An unintended use may lead to personal injuries or proper...

Страница 9: ...troduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2 Copyrigh...

Страница 10: ...used to store the appliance when relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Particularly...

Страница 11: ...eam production by means of direct injection Temperature control stepless Type of guide rails crosswise Continuous operation Thermal core probe connection side Easy regulation of vapour extractor Inter...

Страница 12: ...CNS 18 10 Number of guide rail pairs 5 Rail format 2 3 GN Distance between guide pairs in mm 74 Temperature range min max in C 50 280 Time setting from to in min 0 120 Number of thermal processing pro...

Страница 13: ...n mm 74 Temperature range min max in C 50 280 Time setting from to in min 0 120 Number of thermal processing programmes 1 Number of thermal processing phases 1 Number of motors 1 Stages of fan speed 2...

Страница 14: ...n mm 74 Temperature range min max in C 50 280 Time setting from to in min 0 120 Number of thermal processing programmes 1 Number of thermal processing phases 1 Number of motors 2 Stages of fan speed 2...

Страница 15: ...mm 74 Temperature range min max in C 50 280 Time setting from to in min 0 120 Number of thermal processing programmes 1 Number of thermal processing phases 1 Number of motors 2 Stages of fan speed 2...

Страница 16: ...technical service personnel as its operation indicates that other elements must be inspected Appliance door contact switch interrupts the appliance operation after opening the door either the heating...

Страница 17: ...entilation openings 4 Thermal core probe connection 5 Fume extractor 6 Humidity discharge valve 7 Fan 2x 8 Guide rails 9 Door 10 Door handle 11 Height adjustable feet 4x 12 Drain tray 13 Grate 14 GN c...

Страница 18: ...ion The appliance is designed to operate in closed rooms and may not be used in open air nor subject to unfavourable atmospheric conditions The appliance may be used in properly ventilated room in ord...

Страница 19: ...it according to regulations in force in the country of installation CAUTION Choking hazard Prevent children from accessing packaging materials for instance plastic bags and EPS elements Check if the...

Страница 20: ...to walls low walls division walls kitchen furniture or other surfaces made of flammable materials Unconditionally observe fire fighting regulations in force Maintain minimum clearance of at least 50 m...

Страница 21: ...closing valve and a filter between them Make sure that the closing valve is installed in an easily accessible place for the user Fig 4 ATTENTION Hydraulic water pressure should be max 3 bar If the wa...

Страница 22: ...the electrical installation suitable for the power value Follow installation indications so that contacts of such an mechanism must feature suitable spacing providing for full discharge with respect...

Страница 23: ...connect a potential equalising cord with section of 4 mm 10 mm Adjustment of Door Locking Pin After placing the appliance in the selected location check the closing mechanism and position of door seal...

Страница 24: ...Parts disassembled during installation of the appliance must be re assembled The main switch of the electric installation must be on and water shut off valve upstream of the appliance must be open Fir...

Страница 25: ...ng cycle an acoustic signal sounds for approx 15 seconds It is off after a couple of seconds 6 Operating Instruction 6 1 Indications for the User WARNING Risk of burns During operation the housing and...

Страница 26: ...nce is installed it is mandatory to place a safety sticker at the height of 1600 mm from the floor saying Risk of burning Hot liquid inside the container which is part of the delivery When grilling or...

Страница 27: ...urz dzenie i el ementy wypos a eni a Setzen Sie di e Boden Abdeckung in das Becken ei n The cover acts as a spacer between the heating element and l eft over food tray Carefull yi nser t the connecti...

Страница 28: ...e c onnecti on box must enter a hol e i n the mai n appliance This way the connection box is properly mounted M 1 Function selector knob I 1 OFF position I 2 Cooking roasting I 3 Cooking roasting with...

Страница 29: ...otate the M 1 function selector knob clockwise to I 2 position 2 Then set the temperature by rotating the M 2 temperature controller clockwise to the selected position 3 To end with set the cooking ro...

Страница 30: ...o set the appliance to 110 C which is marked as I 5 at the temperature scale 3 To end with set the cooking roasting time by rotating the M 3 timer clockwise to the selected position After the set time...

Страница 31: ...wise to the selected position 3 To end with set the cooking roasting time by rotating the M 3 timer clockwise to the selected position After the set time has expired an acoustic signal will sound and...

Страница 32: ...the M 3 timer to I 6 position unlimited time Set the remaining parameters stem injection fan speed as needed 3 To activate the thermal core probe set the T 1 switch to I 10 position 4 Use the D 1 dig...

Страница 33: ...ress the red lock B again and remove the thermal core probe C 5 Release the red lock B 6 Re fit the plug A in the connection location Fig 12 Fig 13 Placing Thermal Core Probe in Proper Location within...

Страница 34: ...y the extractor Fig 14 We recommend to set the discharge valve lever in closed position P1 for Steaming and Combi steaming Interior Lighting Lighting of the thermal processing chamber is automated and...

Страница 35: ...on stick aluminium trays or special frying baskets Set the oven to convection with the valve open at temperature of 250 C and ventilation between 4 and 6 Recommendations for cooking uniformity The uni...

Страница 36: ...product must be quickly cooled down to 3 C to end the pasteurisation process 7 Cleaning and Maintenance 7 1 Safety Instructions for Cleaning Before cleaning disconnect the appliance from the power su...

Страница 37: ...chamber thoroughly 5 In the case of stubborn soiling use special cleaning agents Observe instructions of such a cleaning agent s manufacturer 6 Clean the appliance from the outside with a soft damp c...

Страница 38: ...rnal glass pane or re insert it correctly and lock latches in their initial positions by turning them counter clockwise Fig 18 Fig 19 Control Panel Ventilation Filter Clean the control panel ventilati...

Страница 39: ...moving the appliance into a new location and prior to its start up make sure that all electrical and water connections have been executed following standard regulations in force 8 Possible Malfunctio...

Страница 40: ...Check if the water shut off valve is open If the malfunction persists contact the service company Thermal core probe does not work Check if the timer is set to I 6 position unlimited time If the malfu...