EN
page 34
7.3 Installation
7.3.1 Positioning the machine
Remove the packing with care.
Lift the machine as described in par.
7.1.1 Handling the product
.
Position the machine as shown on the installation diagram (lay-out) approved
at the time of the off er.
Maintain a minimum distance of about 50 mm from the walls, so that motors
are ventilated (see pict. 5). Install suction hoods to assure proper ventilation of
the room, in order to eliminate steam and excessive humidity.
Check that the machine is properly levelled, by adjusting the legs (see pict. 6).
Make sure the machine is not standing on the power cable or on the fi lling/drain
hoses. Level the machine fl at, by adjusting the support feet.
7.3.2 Electrical connection
The electrical connection shall be carried out in accordance to the local laws
in force.
Moreover, the machine has a clamp at the back indicated by the symbol
that is meant
to connect the metal structure and masses among diff erent apparatuses, to prevent electro-
static electrical shocks.
The electrical supply cable must be new, fl exible, and according to "har" H07RN-F or a local
valid equivalent. The cable size is dimensioned according to the power.
Should the electrical supply cable get damaged it shall be changed by the Manufacturer, or his Authorized Service, or other
technician with equivalent qualifi cation, to prevent any risk.
If the machine is fi tted with a three-phase pump, check the correct motor rotation (right rotation as per arrow on the casing).
7.3.3 Water connection
Connect the machine draining hose to the connection located under the tank, making sure that the water fl ows freely
(optimizing the slope).
Should not be possible to drain the water at a level lower than the appliance outlet (see pict. 4), it's advisable to choose a
machine provided with a drain pump.
The drain tube shall always be connected to a siphon in order to prevent the release of odors.
7.3.4 Start-up
At installation engineer’s care.
8. SIGNALS AND ALARMS
When displaying
DETERGENT LEVEL
add detergent in the detergent tank (only with optional "Sensor for
Chemicals Low Level").
When displaying
RINSE-AID LEVEL
add rinse-aid chemical in the rinse-aid tank (only with optional "Sensor
for Chemicals Low Level").
When displaying
SHUT DOOR
means that the open door does not allow the maneuver tried, or a wash cycle was in progress,
when lifting the door.
When displaying
DRAIN WATER IN WASH TANK
means that a full wash-tank does not allow the maneuver tried
When displaying
LOAD WATER IN WASH-TANK
means that the wash-tank is empty and does not allow the manoeuvre tried.
?
Fig. 6
50 mm
Fig. 5