Possible Malfunctions
26 / 35
104523
EN
7
Possible Malfunctions
Mögliche
ATTENTION!
The table below contains descriptions of possible causes and solutions to
malfunctions or errors during operation of the appliance. These
malfunctions may be cleared by a qualified refrigeration technician.
In such a case, provide article number, model name and serial number. These data
may be found in the rating plate.
Malfunction
Alarm
Appliance Condition
Solution
Too long a cooling
cycle alarm
Check condenser for ventilation
Check the cooling circuit for loss
of coolant
Reducing the size of ice cubes
Time interval
change between
two production
cycles alarm
Time interval between
two production cycles
changed
Check condenser for cleanliness
and ventilation
Check condenser's fan
Check the circulation for loss of
the coolant
Reducing the size of ice cubes
No water alarm
Appliance stops or waits
for another attempt of
automatic start-up
Check water supply
Check water circulation for water
leaks
Check water inlet valve for
operation, clean if necessary