BARTINGTON INSTRUMENTS

 

Page 2 of 8 

OM3836/2

Table of Contents

1. About this Manual 

3

1.1. Symbols Glossary 

3

2. Safe Use 

3

3. Introduction  

4

4. General Description 

4

5. Connections 

4

5.1. Cable Recommendations 

4

5.2. Connection to Power Supply/Acquisition Unit 

5

6. Using the Mag646 

5

6.1. Mag646 Operation 

5

6.2. Electromagnetic Compatibility 

6

7. Troubleshooting 

6

8. Care and Maintenance 

7

8.1. Calibration 

7

9. End of Life Disposal 

7

Содержание Mag646

Страница 1: ...www bartington com INNOVATION IN MAGNETICS Operation Manual for Mag646 Single Axis Unpackaged Magnetic Field Sensor OM3836 2 ...

Страница 2: ...afe Use 3 3 Introduction 4 4 General Description 4 5 Connections 4 5 1 Cable Recommendations 4 5 2 Connection to Power Supply Acquisition Unit 5 6 Using the Mag646 5 6 1 Mag646 Operation 5 6 2 Electromagnetic Compatibility 6 7 Troubleshooting 6 8 Care and Maintenance 7 8 1 Calibration 7 9 End of Life Disposal 7 ...

Страница 3: ...ation in which bodily injury or damage to your instrument or both could result if the caution is ignored Indicates a situation in which ESD protection should be used Identifies items that must be disposed of safely to prevent unnecessary damage to the environment Note A paragraph in this format provides useful supporting information on how to make better use of your purchase 2 Safe Use WARNING The...

Страница 4: ...nction Regulating the power supply internally ensures that the Mag646 is suitable for battery powered operation over both long and short cables 4 General Description Figure 1 Mag646 sensor Key 1 PCB header 2 Sensing Element 3 Mounting Holes 5 Connections 5 1 Cable Recommendations The Mag646 electronics board provides unbalanced output lines for analogue signal transmission Suitable shielded cables...

Страница 5: ... currents which could cause damage Note Apply the positive and negative supplies simultaneously and avoid leaving the electronics board connected to one polarity only The analogue output of the sensors as well as the power supply connectors are available on the outline drawing DR2945 Where no Bartington power supply or acquisition unit is used some basic recommendations for integration of the sens...

Страница 6: ...nstruments service team on 44 0 1993 706565 Problem Cause Solution There is no analogue output present in Z Sensor head not connected Ensure that the sensor head and electronics are connected as per Cable Recommendations Power supply not connected or not sufficient to power the sensor Check that the power supply meets the requirement provided in DS3836 and that the connection is as per Connection ...

Страница 7: ...cy noise Check that a suitable low pass filter is used or that the signal is sampled at a suitable frequency at least twice the breakthrough frequency 8 Care and Maintenance Surface dirt contamination on the Mag646 probe should be removed using a mild detergent solution only Electronics should be cleaned with an antistatic cloth only ESD protection should be used when handling the Mag646 electroni...

Страница 8: ...England The copyright of this document is the property of Bartington Instruments Ltd Bartington is a registered trademark of Bartington Instruments Limited in the following countries Australia Brazil Canada China European Union India Israel Japan Mexico New Zealand Norway Russia Singapore South Korea Switzerland Turkey United Kingdom United States of America and Vietnam ...