Mini-PLC
STG-115
Art. No. 0850-0115

MANUAL

© 2014-2015 BARTH Elektronik GmbH | Im Depot 1-3 | D-49838 Lengerich | www.barth-elektronik.de
® BARTH is a registered trademark. All rights reserved.

9021-0003-A

Creating a new project the desired Mini-PLC model and the 
project name have to be defined.
After opening or creating a project the workspace of miConL 
with it´s libraries (right) is shown.

Additional help and a detailed user manual is provided 
within the miCon-L help and the miConL context menu 
(right mouse button).

APPENDIX

7.1 

Specifications

7.1.1  General

Hardware design

BARTH

®

 Mini-PLC, splashproof 

panel mount version, super-flat 
and rugged housing with plugable 
spring terminal connectors

Programming

miCon-L Software,
graphical (function block style),
simulation, programming and 
visualisation, free license model

Interfaces

USB
reserved for miCon-L software
communication only

7.1.2  Power supply

Operating voltage

16 to 32 VDC

Current consumption 

< 7 mA at 32 VDC
LCD backlight switched off
in miCon-L application

Fusing 

8 A max. (external)
mandatory for voltage reversal 
protection

Voltage reversal protection

yes
(combined with external fuse)

ESD/TVS protection

yes

Heat dissipation
(at full load)

normally < 4 W

7.1.3  Inputs

Number analog

8+2

Analog input IN1 - IN8

U

IN

 = 0..30 VDC

R

IN

 > 11 kOhm

f

IN

 <= 100Hz

t

IN

 >= 10 ms

Analog input IN9 - IN10

U

IN

 = 0 to 10 VDC

R

I

 = 470 Ohm

I

IN

 = 4 to 20 mA (DIP switchable)

Accuracy ADC
IN1 - IN8

± 3% (0.5 VDC)

ADC resolution
(internal)

10 Bit

Potential isolation

no (common GND)

ESD/TVS protection

yes

Permissible cable lenght
(per input)

normally 40 m

Содержание Mini-PLC STG-115

Страница 1: ...n 2 4 4 Programming with miCon L 3 4 5 Delivery content 3 5 INSTALLATION 3 5 1 Mounting 3 5 2 Wiring 4 5 3 Overview 4 5 3 1 Connecting the power supply 4 5 3 2 Connecting the inputs 4 5 3 3 Connecting...

Страница 2: ...he strict accordance of this manual is important since the installation methods peripheral connections usage and maintenance can not be con trolled by BARTH Elektronik GmbH Therefore BARTH Elektronik...

Страница 3: ...lease read the BARTH miCon L manual and the BARTH Application Notes on www barth elektronik de 4 5 Delivery content BARTH Mini PLC STG 115 Spring terminal connectors for supply input output 5 INSTALLA...

Страница 4: ...ch 1 of the S1 DIP switch from ON to OFF To change the input IN10 from 4 20mA to 0 10V please set the switch 2 of the S1 DIP switch from ON to OFF Switches 3 and 4 of S1 are not related to any functio...

Страница 5: ...NO NC switch A logical HIGH within miConL will switch the Mini PLS s supply voltage at OUT1 to OUT8 while the isolated contact of OUT9 changes over NC NO NO NC Aviod a current exceeding 1A 30VDC at OU...

Страница 6: ...ged housing with plugable spring terminal connectors Programming miCon L Software graphical function block style simulation programming and visualisation free license model Interfaces USB reserved for...

Страница 7: ...charge ESD on IN1 to IN10 20 kV air discharge 30 kV contact discharge IEC EN 61 000 4 2 level 3 Electrostatic discharge ESD on OUT1 to OUT9 8 kV human body model MIL STD883D Electromagnetic fields Fie...

Страница 8: ...e event of any alternation which has not been approved by us being made to any device as designated below this statement shall thereby be made invalid Description Mini PLC Type STG 115 Art No 0850 011...

Отзывы: