lococube®
PeopleCounter PC-10
MANUAL
(EN)
© 2020 BARTH Elektronik GmbH | Im Depot 1-3 | D-49838 Lengerich | www.barth-elektronik.de | [email protected]
® BARTH and lococube are registered trademarks of BARTH Elektronik GmbH. All rights reserved to make changes without prior notice.
5
Mirror Setup
Ensure that light beams
points right-angled to the
place where the mirror will
be mounted. Take the mirror
and move it with a maximum
distance of 6m in the light
beam direction and observe
‚STOP‘ and ‚GO‘ traffic lights.
Only if both traffic lights are
off, the correct setup has
been reached and the mirror
is placed properly. Move
the mirror twice to find safe
operation area and then fix it
to the wall. Aviod moving the
PeopleCounter now which
would cause malfunction and
the need of a new setup.
6
Setup people limit
To setup the maximum
allowed number of people in
the room, simply type in the
desired value, clearing with
‚ESC‘ and confrming with
‚OK‘.
7
Operation
After successful setup the
PeoplyCounter is ready to
operate and the buzzer shuts
down. The Touch-LCD shows
the current number of people
in the room and also the
preset maximum value.
During normal operation the
green ‚GO‘ is lighted.
If the maximum number of
people is reached, the red
‚STOP‘ light appears.
If a person enters the room
during red ‚STOP‘ light, the
buzzer sounds and indicates
prohibited access.
8
Repowering
If the PeopleCounter is recon-
nected to the mains (after
power supply interruption or
shut-down) the people limit
has to be set again.
Automatic restoring the value
is not provided due to the
unknown number of people in
the room after shut-down.
9
People count correction
To manually correct the
number of people in the room
(in case of countig errors or
setup failures) simply move
you hand in direction of the red
arrow to increase the number
of people or in direction of the
green arrow to deacrease the
number of people.
4
Get Support
Detailed product support is availabe on:
https://barth-elektronik.com/support
5
Appendix
5.1
Specifications
5.1.1 General
Hardware design
and contruction
Heavy duty strut profile based
construction (BOSCH Rexroth®
System.
Controller and HMI
Internal lococube® mini-PLC
STG-800 with CAN bus and
5 I/Os
DMA-15 Touch HMI 2,4“ color
Sensor
Two SICK® visible light barrier
beam sensors connected to
mini-PLC
Signal lights
5x Power LED modules 12V/3W
directly driven by mini-PLC
5.1.2 Power supply
Operating voltage
external:
100..240VAC/50/60Hz 0.7A
internal:
12VDC 2.08A
Adaptor Art. No. 0043-0041
5.1.3 Interfaces
CAN (internal)
CAN 2.0A/B:
11/29 bit ID, base frame format
TTL232 (internal)
3.3V TTL level, config: 8N1
Baud rates: 2400 to 115.2 kbit/s
5.1.4 Security features
Security Features
System and independent WD
Fail safe oscillator
Power on/down reset
Supply voltage supervisor