background image

7

 

Rev. 1.2 (04.2020)   

 

         

 

Pin description 

Pin 

Name 

Function 

 

1,2,17,18 

NC 

This pins should not be connected and left floating 

GND 

Ground 

CLK 

Predefined  clock  signal.  Frequency  will  be  set  to  the 
nominal 200 Hz, when this pin is connected to CLK_INT 
(see image “Schematic 1” in chapter 0). 
It  is  also  possible  to  connect  an  external  clock  signal 
with  a 

quadruplicated

  frequency  of  the  micropumps 

frequency.

 

CLK_INT 

When  connected  to  CLOCK  the  frequency  is  set  to 
200 Hz. 

AMP 

The  amplitude  can  be  set  with  an  analogue  voltage 
between 0.5 V to 1.3 V. 

A0 

Address Input 0. Address inputs allow up to four 
connections on one common bus. Connect A0 to GND or 
VDD. 

P1+ 

Piezo actuator 1, positive electrode (see page 9) 

P1- 

Piezo actuator 1, negative electrode (see page 9) 

10 

P2- 

Piezo actuator 2, negative electrode (see page 9) 

11 

P2+ 

Piezo actuator 2, positive electrode (see page 9) 

12 

A1 

Address Input 1. Address inputs allow up to four 
connections on one common bus. Connect A1 to GND or 
VDD. 

13 

SCL 

Serial-Clock Input. SCL requires an external pullup 
resistor. 

14 

SDA 

Open-Drain, Serial Data Input/Output. SDA requires an 
external pullup resistor. 

15 

/RESET 

If the I2C-Bus is to be used, the internal processor has to 
be disabled by applying GND to this pin. Otherwise 
connect this pin to VDD for normal operation. 

16 

VDD 

Input Supply voltage 

 

 

 

Содержание microComponents mp6-XOEM

Страница 1: ...1 Rev 1 2 04 2020 Operating Manual for Controller mp6 XOEM...

Страница 2: ...this operating manual 4 The mp6 XOEM controller 5 Technical specifications mp6 XOEM 5 Electrical Characteristics 6 Pin description 7 Connecting the micropump with the mp6 XOEM 8 Examples of circuiting...

Страница 3: ...ant to the EU Low Voltage Directive 2014 35 EU Description of functions The micropumps have been developed for the transport of gases or liquids The controllers have been developed for operating the m...

Страница 4: ...ditions including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning...

Страница 5: ...w additional components or a microcontroller In order to locate Pin 1 please refer to the following figure The pin is marked with a colored spot or triangular marking on the corner of the PCB Technica...

Страница 6: ...LITUDE 0 5 1 3 VDC min voltage at pump Vpump AMPLITUDE 0 5 VDC 10 Vpp max voltage at pump 1 Vpump AMPLITUDE 1 25 VDC 250 260 270 Vpp Frequency output F VDD 5 V Default 200 Hz Digital Low Signal 0 V Di...

Страница 7: ...ut 0 Address inputs allow up to four connections on one common bus Connect A0 to GND or VDD 8 P1 Piezo actuator 1 positive electrode see page 9 9 P1 Piezo actuator 1 negative electrode see page 9 10 P...

Страница 8: ...d with the mp6 XOEM via a FCC connector More information concerning this connector and the pin layout of the micropump can be found in manual of the micropump mp6 series DANGER The output of the mp6 X...

Страница 9: ...amplitude to the micropump will be defined by external components The amplitude can be varied in the range from 0 Vpp to 250 Vpp Using a voltage divider it is possible to set the amplitude with only...

Страница 10: ...citor This can only be done my supplying a clock signal to the CLK pin witch is shown in the next chapter Operation with variable settings via microcontroller Using a microcontroller to operate the mi...

Страница 11: ...f the mp6 QuadOEM on our download page To activate the I C Interface the onboard processor has to be deactivated by tying the reset pin to Ground Select a desired slave address connecting pins A0 and...

Страница 12: ...l 49 231 47730 500 Fax 49 231 47730 501 Visit our Website www bartels mikrotechnik de for further information on applications Tutorials and helpful answers to frequently asked questions can be found i...

Отзывы: