Pneumatic connections
The Ex p control unit type 07-37A2-3211/2726 provides the following pneumatic
connections.
Connection Designation
Remark
(1)
Purge gas supply
G1/4“i
(2)
Purge gas feed Ex p
G1/4“i
(3)
Purge gag return Ex p
G1/4“i
(4)
Purge gas outlet
M36 inner thread
(a)
Setting of purge gas volume
Throttle valve
(b)
Setting of continuous purge
Throttle valve
(c)
Pressure measurement
Changes not allowed
(d)
Pressure measurement connections
Changes not allowed