Getting Started 31
Connecting the Barracuda Load Balancer to the Network
1.
Fasten the Barracuda Load Balancer to a standard 19-inch rack or other stable location.
2.
If using
Route-Path
, then the network switch referenced in the following steps may be the same
physical switch. If using
Bridge-Path
, however, then
separate
switches on different Layer 2
networks
must
be used.
2a.
Connect a CAT5 Ethernet cable from the
WAN
interface on the Barracuda Load
Balancer to the network switch where the
VIPs
reside.
2b.
Connect a CAT5 Ethernet cable from the
LAN
interface on the Barracuda Load
Balancer to the network switch where the
Real Servers
reside.
3.
Connect the following to your Barracuda Load Balancer:
• Power cord
• VGA monitor
• PS2 keyboard
After you connect the AC power cord, the Barracuda Load Balancer may power on for a few
seconds and then power off. This behavior is normal.
4.
Press the
Power
button located on the front of the unit.
The login prompt for the administrative console displays on the monitor, and the power light on
the front of the Barracuda Load Balancer turns on. For a description of each indicator light, refer
to the section that describes the model of your Barracuda Load Balancer in
Configuring WAN IP Address and Network Settings
The Barracuda Load Balancer is assigned a default WAN IP address of 192.168.200.200. You can
change this IP address using the administrative console or by pressing the
RESET
button on the front
panel.
Pressing
RESET
for five seconds sets the WAN IP address to 192.168.200.200. Pressing
RESET
eight seconds changes the WAN IP address to 192.168.1.200. Pressing the button for 12 seconds
changes the WAN IP address to 10.1.1.200.
To set a new WAN IP address from the administrative console:
1.
Connect your keyboard and monitor directly to the Barracuda Load Balancer.
2.
At the
barracuda login
prompt, enter
admin
for the login and
admin
for the password.
Caution
Do not block the cooling vents located on the front and rear of the unit.
Caution
Do not connect any other cables to the unit. The connectors on the back panel are for diagnostic
purposes only.
Содержание Load Balancer
Страница 6: ...vi Barracuda Load Balancer Administrator s Guide...
Страница 14: ...14 Barracuda Load Balancer Administrator s Guide...
Страница 18: ...18 Barracuda Load Balancer Administrator s Guide Figure 2 2 A physical network layout using Route Path...
Страница 28: ...28 Barracuda Load Balancer Administrator s Guide...
Страница 42: ...42 Barracuda Load Balancer Administrator s Guide...
Страница 62: ...62 Barracuda Load Balancer Administrator s Guide...