Barox PD-BTPMC102M-GE Скачать руководство пользователя страница 1

 

 

 

 
 

 

 
 
 
 
 
 
 

User Manual: PD-BTPMC102M-GE 

Industrial Media converter lite managed with PoE af/at/bt 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Version 3.2021 

 

 

 

Содержание PD-BTPMC102M-GE

Страница 1: ...User Manual PD BTPMC102M GE Industrial Media converter lite managed with PoE af at bt Version 3 2021...

Страница 2: ...etwork management software ISMS One which includes dashboards configuration settings and MQTT publish allowing the administrator to manage centrally for easily deploying controlling and monitoring Sup...

Страница 3: ...wer budget to select the voltage range Hardware Description On the top panel the following interfaces are placed Wiring the Alarm Contact Wiring the Power Inputs DIP Switch Setting Reset Configuration...

Страница 4: ...gauge 5 2kgf cm MAX torque Wiring the Power Inputs The power contact wires at the two right and two left sides of the 6 contact terminal block connector are used for two DC Inputs STEP 1 Insert the po...

Страница 5: ...t over the DIN Rail STEP 2 Push the bottom of the unit towards the DIN Rail until it snaps into place Removal Step STEP 1 Push the unit down to free the bottom of the DIN Rail STEP 2 Rotate the bottom...

Страница 6: ...r is provided from power input 2 SYS Green ON System is working ALARM Red ON Alarm happens PoE1 Green ON Power output is on port 1 PoE2 Green ON Power output is on port 2 SFP 1000 Green ON SFP is at 1...

Страница 7: ...is set to ON mode and LFPT function is enabled If using web page to control LFPT function and the mode is set to ON LFPT function can be set to enable or disable in web page The function is to pass l...

Страница 8: ...se fill in the default username admin and the default password 2wsx EDC and then click Login For the system security changing the default password is strongly suggested after configuration You can go...

Страница 9: ...Page 9 13 The system status is shown as below This section includes Switch Port Status PSE Port Status Alarm Status and DIP Switch...

Страница 10: ...bled The relay alarm event will return to the normal status when the temperature is small than 100 degrees C PWR When the power is failure from Power Input 1 or Power Input 2 the relay alarm event is...

Страница 11: ...Power on device and wait 90 seconds Step2 When Ethernet link is connected the device will send the ping request every 15 seconds Step3 When the ping response is received reset the ping counter and go...

Страница 12: ...vice default configuration After clicking Load Default item it will be shown the interface as below to make sure if you are ready to load or not Reboot the device After clicking Reboot item it will be...

Страница 13: ...ined by service persons or by users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken All electric installations mus...