background image

 

 

 

 

 

 

Dimensions 

in mm 

(inch) 

– Electronic temperature sensor UTF 2 

 

 

Operating Instructions 

Electronic Pressure and Temperature Transducers 

UPA 2, UTA 2 and UTF 2 

 

 

 

1

 

Intended Applications ................................................................................................... 2

 

2

 

Safety Instructions ......................................................................................................... 2

 

3

 

Standards ....................................................................................................................... 3

 

4

 

Warranty/Guaranty .........................................................................................................  3

 

5

 

Installation/Commissioning ..........................................................................................  3

 

6

 

Maintenance/Cleaning ...................................................................................................  5

 

7

 

Technical Data ................................................................................................................ 5

 

 

 

Barksdale GmbH 

Dorn-Assenheimer Straße 27 

D-61203 Reichelsheim 

Phone: 

+49 (6035) 949-0 

Fax: 

+49 (6035) 949-111 and 949-113 

eMail: 

HHHH

[email protected] 

Internet: www.barksdale.de 

 

 

 

Art. no. 923-1910 

Index: C, 15.08.2018 

 

Specifications are subject to changes 
without notice! 

 

M12x1

A

B

ØG1/4"

L0 

12 

(0.47

Ø6 

(0.74)

 

56 

(2.22

70 

(2.76

Ø27 

(1.06)

 

Содержание UTA 2

Страница 1: ...4 Warranty Guaranty 3 5 Installation Commissioning 3 6 Maintenance Cleaning 5 7 Technical Data 5 Barksdale GmbH Dorn Assenheimer Straße 27 D 61203 Reichelsheim Phone 49 6035 949 0 Fax 49 6035 949 111 and 949 113 eMail HHHHinfo barksdale de Internet www barksdale de 1 8 Art no 923 1910 Index C 15 08 2018 Specifications are subject to changes without notice M12x1 A B ØG1 4 L0 12 0 47 Ø6 0 74 56 2 22...

Страница 2: ...ion essential to the user Disposal The electronic measuring device must be disposed of correctly in accordance with the local regulations for electric electronic equipment The electronic measuring devices must not be disposed of with the household garbage 3 2B2B2B2BStandards The standards applied during development manufacture and configuration are listed in the CE conformity and manufacturer s de...

Страница 3: ... UPA 2 UTA 2 Current output 4 20 mA two wire system Voltage output 0 10 V DC three wire system Connection Plug Cable GL cable M12 Plug Cable GL cable M12 Supply 1 brown white 1 1 1 brown blue 1 1 Supply 2 white blue 1 2 2 blue blue 2 3 Signal 3 white white 1 2 Signal Connection chart for temperature sensor UTF 2 PT100 Plug M12 x 1 4 pin 6 5B5B5B5BMaintenance Cleaning The electronic measuring devic...

Страница 4: ...nection G1 2 acc to DIN ISO 228 1 flush at the front B Profile seal acc to DIN 3869 C Cable gland Pg 11 clamping range Ø 6 8 mm Dimensions in mm inch Electronic temperature transducer UTA 2 7 6 M12x1 15 0 59 A 28 1 1 81 3 3 20 Ø18 9 0 74 G1 4 L0 12 0 47 Ø6 0 74 11 0 42 Ø27 1 06 ...