20-21
®
IMPLEMENT PUMP SETTING- WFB
BARKO Machine Applications for IMPLEMENT PUMP:
BARKO P/N
Barko Application
Ÿ
560-02943
830B
Setting the standby pressure ensures there is enough
pilot oil to shift the control valve(s).
Setting the system
pressure ensures lifting capacities can be reached and
maintained.
425 PSI
is the factory recommended standby
pressure value.
4000 PSI
is the factory maximum system
pressure value.
1 Implement Pump Pressure Setting Procedure (refer to Fig-1):
6.
1.
2.
4.
5.
3.
7.
Adjust standby pressure to
425 PSI
(29.3
bar).
Tighten set screw on the
LS
Adjustment.
Note:
Verify the Standby Pressure does
not change after you have tightened the
set screw.
Start machine.
Turn on control power.
Loosen set screw on the
LS
Adjustment.
Install pressure transducer or 5000 PSI gauge
on
M2
port of the implement pump.
Run engine at quarter throttle
(1175 RPM)
.
Remove pressure transducer.
Loosen set screw on the
PC
Adjustment.
Tighten set screw on the PC Adjustment.
Note:
Verify the System Pressure does
not change after you have tightened the
set screw.
Return engine to an idle.
Turn machine off.
Release tilt function.
Bottom out tilt function and hold.
Adjust system pressure to
4000 PSI
(275.8
bar).
14.
15.
13.
9.
8.
10.
11.
12.
Fig-1
IMPLEMENT PUMP
M2 PORT
LS ADJ
(6mm)
PC ADJ
(6mm)
SET SCREWS (2X)
(4mm)
05/30/2019
Updated
SERVICE
Содержание 830B
Страница 4: ...THIS PAGE INTENTIONALLY BLANK SUPERIOR WI USA www barko com...
Страница 42: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 44: ...20 2 SUPERIOR WI USA www barko com Part No 605 01591 HYD AY WFB 830B 05 30 2019 Updated SERVICE...
Страница 45: ...20 3 SUPERIOR WI USA www barko com Part No 605 01591 HYD AY WFB 830B 05 30 2019 Updated SERVICE...
Страница 48: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 50: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 54: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 60: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 70: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 94: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 102: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 104: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 113: ...26 11 SERVICE HEATER AC UNIT WFB continued 1 2 2 Fig 3 548 04558 Schematic Fig 3 05 31 2019 Updated SERVICE...
Страница 114: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 118: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 124: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 133: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 134: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 138: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 172: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 181: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 182: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 184: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 194: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 207: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 208: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 210: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 215: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 216: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Страница 217: ...THIS PAGE LEFT INTENTIONALLY BLANK...