barfield 1811D Series Скачать руководство пользователя страница 1

 

 

 
 

 

 

 
 
 
  

 

1811D (SERIES)

 

PITOT-STATIC TEST SET 

 

 

 

 

 

 

 

USER INSTRUCTION MANUAL     

 

 

 

M/N: 1811D, P/N: 101-00164-SERIES 

 

 

 

 

 Doc. 

P/N: 

56-101-00164 

 Revision 

 

April 19, 2013 

 

 ____________________________________ 

  

 BARFIELD, 

INC. 

 

                                                          

 

 
 

 

   

 

 Corporate 

Headquarters 

 

4101 Northwest 29th

 

Street 

 
Miami, Florida 33142 
 

 www.barfieldinc.com 
 

 

Email: [email protected] 

Barfield Inc. Confidential and Proprietary Information
This document and all the information contained herein is the sole property of Barfield Inc. 
No intellectual property rights are granted by the delivery of this document or the disclosure of its content. 
This entire document is proprietary information and shall not be reproduced or disclosed to a third party without 
the express written consent of Barfield Inc. 
This document and its content shall not be used for any purpose other than that for which it is supplied.

 

Содержание 1811D Series

Страница 1: ...ld Inc Confidential and Proprietary Information This document and all the information contained herein is the sole property of Barfield Inc No intellectual property rights are granted by the delivery...

Страница 2: ......

Страница 3: ...ion or error found in this manual Inquiries should include specific questions and reference the publication title number chapter page figure paragraph and effective date Please send comments to TECHNI...

Страница 4: ...e and return the enclosed OWNER WARRANTY REGISTRATION CARD to Barfield in order to validate the warranty and to ensure that you will receive updated information when published You MUST have your name...

Страница 5: ...vertises its 1811 series Test Sets as general purpose trouble shooting testers With respect to compliance with FAR 91 411 we feel that the customer should first be aware of all requirements for perfor...

Страница 6: ...ng were reorganized C 260 00746 Dec 16 2008 A numeric code was added at the end of the former P Ns to identify the instruments configuration supplied with a particular unit D 260 00779 Apr 29 2010 Add...

Страница 7: ...function contact the manufacturer to obtain the list of approved repair facilities worldwide ensuring that this equipment will be serviced using proper procedures and certified instruments BARFIELD PR...

Страница 8: ...1811D INSTRUCTION MANUAL 56 101 00164 Rev F Blank Apr 19 13 Page viii THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 9: ...Figures and Tables SECTION PAGE INTRODUCTION 1 PUBLICATION BREAKDOWN 1 2 INFORMATION PROVIDED WITH THE UNIT 1 3 RECERTIFICATION 2 1 DESCRIPTION 1 GENERAL DESCRIPTION 5 2 PHYSICAL DESCRIPTION 6 2 SPEC...

Страница 10: ...T 19 10 MACHMETER TEST 22 11 ENGINE PRESSURE RATIO TEST 23 12 MANIFOLD PRESSURE GAUGE TEST 23 13 LOW PRESSURE TEST 24 14 VACUUM TEST 26 4 VALVE LEAK TEST 1 METERING VALVE ADJUSTMENT PROCEDURE 27 2 RES...

Страница 11: ...nty 3 1 3 1811D Pitot Static Test Set 5 1 4 Leading Particulars 6 7 3 5 1811D Operational Schematic Diagram 11 3 6 1811D Plumbing Schematic Diagram 12 3 7 1811D Panel Mounted Components 13 3 1 Airspee...

Страница 12: ...1811D INSTRUCTION MANUAL 56 101 00164 Rev F Blank Apr 19 13 Page xii THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 13: ...below A An identification label similar to Figure 1 and located on the front bulkhead of the Test Set provides the following information Manufacturer Name Designation of Equipment Equipment Part Numbe...

Страница 14: ...ions on digital instruments refer to documents 61 101 02184 and 61 101 02194 It is strongly recommended that the manufacturer Barfield Inc service the Test Set This will ensure that all applicable eng...

Страница 15: ...1811D INSTRUCTION MANUAL 56 101 00164 Rev F INTRO Apr 19 13 Page 3 of 38 LIMITED ONE YEAR WARRANTY Figure 2...

Страница 16: ...1811D INSTRUCTION MANUAL 56 101 00164 Rev F Blank Apr 19 13 Page 4 of 38 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 17: ...50 to 650 knot sensitive airspeed and is available with a 35 000 or 50 000 ft altimeter The tester consists of a hand operated vacuum pump a hand operated pressure pump vacuum and pressure gauges 5 co...

Страница 18: ...altimeter Airspeed Code Airspeed Range Altimeter Code Altimeter Range 1 650 knots 50 650 kts 2 Precision dual diaphragm 3 ptr 80K range cal to 55k 4 420 knot 60 420 kts 3 Sensitive 3 ptr 50 000 ft 6...

Страница 19: ...TANK 0 30 In Hg Vacuum Gauge Used to monitor vacuum available in vacuum reservoir tank E ALTIMETER Monitors pressure altitude at vacuum static side of Test Set 6 CALIBRATION CARD ALTIMETER Provides a...

Страница 20: ...1811D INSTRUCTION MANUAL 56 101 00164 Rev F Blank Apr 19 13 Page 8 of 38 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 21: ...ations in the Appendix for Specifications and Accuracy Information 1 PHYSICAL DATA A Height 11 3 In 28 7 cm B Width 18 0 In 45 7 cm C Depth 12 0 In 30 5 cm D Weight 18 0 lbs 8 2 kg 2 INPUT POWER The 1...

Страница 22: ...1811D INSTRUCTION MANUAL 56 101 00164 Rev F Blank Apr 19 13 Page 10 of 38 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 23: ...ance their respective systems with atmospheric pressure A crossbleed valve controls the pressure difference in the pressure and vacuum lines of the tester Operating the appropriate valve creates contr...

Страница 24: ...stop spacers on all needle valves to permit the valve to firmly close without damage However excessive force may overpower the knob set screw causing valve damage To avoid incorrect results or damage...

Страница 25: ...and valves 2 Pump pressure to 20 psi and vacuum to 20 inHg with PRESSURE pump A and VACUUM pump H 3 Open PRESSURE VALVE 1 until AIRSPEED INDICATOR D shows 300 knots Close valve and monitor the airspee...

Страница 26: ...craft leak test to the recorded rate D Instrument Calibration Correction Before attempting calibration tests of aircraft instruments ensure that instrument correction card calibration dates are within...

Страница 27: ...If any of the following steps fail close the PRESSURE VALVE 1 fully CW Gently open the PRESSURE 2 vent valve CCW to return the system to ambient atmosphere before disconnecting the T S 6 Monitor the...

Страница 28: ...VACUUM TANK gauge G Note If the vacuum needs refilling close the valve 5 before operating the hand pump 5 Close the VACUUM VENT 4 fully 6 Set both T S and aircraft altimeter barometric scales to 29 92...

Страница 29: ...st Pressurized Aircraft or for an altitude indication of more than 1 000 ft above field level ambient 1 Preliminary Note Perform all steps described in tests 5 PRETESTS 6 PITOT SYSTEM TEST and 7 STATI...

Страница 30: ...t the altimeter reading decreases no more than 100 ft or 2 of the indicated altitude whichever is greater Note If the system shows a leak carefully watch the T S AIRSPEED INDICATOR D When airspeed poi...

Страница 31: ...itude tests below field elevation this test may be omitted 1 Open the CROSSBLEED 3 valve fully While ensuring not to exceed the aircraft VSI full scale range gently open the PRESSURE valve 1 to reach...

Страница 32: ...lves closed gently open the PRESSURE valve 1 to take the airspeed to the test point 4 Gently open the PRESSURE valve 1 so that the airspeed goes to 10 knots below the next higher airspeed test point N...

Страница 33: ...knots Open valve fully 2 Monitor the VSI Open the PRESSURE VENT 2 valve Do not exceed the VSI scale range Caution Do not use the VACUUM VENT 4 to bleed system Severe instrument damage could result 3 O...

Страница 34: ...t to 10k with airspeed of 277 kts would give a MACH reading of 50 MACH NUMBER 50 60 70 75 80 82 85 90 Altitude In feet Airspeed In kts 277 334 391 420 449 10k 247 298 350 376 403 414 429 15k 228 275 3...

Страница 35: ...Port ALTITUDE feet Pt2 Lo Port EPR Engine Pressure Ratio 650 25 870 3 4 546 35 000 3 4 650 21 650 3 0 504 35 000 3 0 650 14 690 2 5 534 25 870 2 5 444 35 000 2 5 650 4 210 2 0 500 20 000 2 0 369 35 0...

Страница 36: ...gradually open PRESSURE 1 valve for test points above field elevation open the VACUUM 5 valve 7 Close the PRESSURE 1 AND VACUUM 5 valves and if necessary use the PRESSURE VENT valve 2 to bleed system...

Страница 37: ...10 180 5 000 135 12 000 0 881 0 433 470 163 308 12 000 5 894 144 13 609 1 000 0 481 474 166 248 12 216 6 000 146 14 000 1 028 0 505 504 190 526 14 000 6 876 155 16 000 1 175 0 577 508 193 955 14 252 7...

Страница 38: ...PRESSURE VENT 2 fully and maintain open for the rest of the procedure 3 Operate the VACUUM PUMP H as required Note The altimeter E operates during this test but the readings are not used Also test set...

Страница 39: ...to 15 PSI 4 Monitor AIRSPEED INDICATOR D for one 1 minute a If an increase in airspeed is seen continue to monitor for an additional five 5 minutes b If during the monitoring period the airspeed incr...

Страница 40: ...TTING NEEDLE VALVE POSITIVE STOP E VERTICAL SPEED VALVE TEST 1 Close all valves except the CROSSBLEED 3 2 If using single action pumps plug the PRESSURE C and VACUUM F ports 3 Empty and maintain the V...

Страница 41: ...beyond the closing point described below When it is determined that a valve is leaking correct the leak before continuing A Firmly close the valve against its positive stop 1 With a 5 64 078 hex wren...

Страница 42: ...1811D INSTRUCTION MANUAL 56 101 00164 Rev F Blank Apr 19 13 Page 30 of 38 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 43: ...strument A0A configuration refer to documents 61 101 02184 DALT55 and 61 101 02194 DAS650 for specifications and recertification intervals 12 Months All of the preceding Plus Check Pressure and Vacuum...

Страница 44: ...1811D INSTRUCTION MANUAL 56 101 00164 Rev F Blank Apr 19 13 Page 32 of 38 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 45: ...nic equipment packaging procedure when packing the Test Set for reshipment To prevent damage from extreme atmospheric changes to the Test Set instruments it is recommended that the STATIC VENT CROSSBL...

Страница 46: ...cool dry place Note Should the Test Set become exposed to moisture or very high humidity dry it as soon as possible and store temporarily in a dehumidified area C To prevent damage from extreme atmos...

Страница 47: ...IX Apr 19 13 Page 35 of 38 APPENDIX BARFIELD INC ENGINEERING SPECIFICATIONS Note For information on compliance with FAR 91 411 refer to Barfield document 60 101 00150 SECTION 1 ALTIMETER SECTION 2 AIR...

Страница 48: ...IX Apr 19 13 Page A of 38 SECTION 1 ALTIMETER The following engineering specification Document No 23 338 00001 details the performance requirements of the pressure sensitive altimeters used by Barfiel...

Страница 49: ......

Страница 50: ...50 000 ft Barometric Pressure Scale range at least 28 1 30 99 inches of Mercury 946 1049 millibars May include markers working in conjunction with Barometric Pressure Scale to indicate pressure altit...

Страница 51: ...the tolerances listed ALTITUDE FEET TOLERANCE FEET 1 000 70 2 000 70 3 000 70 5 000 80 10 000 90 15 000 100 20 000 125 25 000 150 30 000 175 35 000 200 40 000 250 50 000 400 TABLE 1 FRICTION 5 3 Hyste...

Страница 52: ...e against the 124 00002 instrument 5 4 After Effect Not more than 5 minutes after the completion of the hysteresis test the pointers shall have returned to their original reading corrected for any cha...

Страница 53: ...4 000 70 4 000 35 6 000 80 6 000 40 8 000 120 8 000 60 10 000 160 10 000 80 12 000 200 12 000 90 14 000 225 14 000 100 16 000 240 16 000 110 18 000 275 18 000 120 20 000 300 20 000 130 22 000 340 22 0...

Страница 54: ...B of 38 SECTION 2 AIRSPEED INDICATOR The following engineering specification Barfield Document No 23 336 00025 details the performance requirements of the pitot static pressure type airspeed indicator...

Страница 55: ......

Страница 56: ...nots 4 Test Conditions Unless otherwise specified all tests shall be made with the instrument mounted in the horizontal Face UP position 5 Performance Requirements All units are required to meet the f...

Страница 57: ...n the dial with the exception of P N s 336 00001 336 00001R and 336 00004 The 336 00001 1R units pointer should rest between 15 45 knots The 336 00004 unit pointer position should rest at 350o 5o 0 po...

Страница 58: ...Knots TOLERANCE Knots 60 3 0 180 4 0 70 3 0 190 4 0 80 3 0 200 5 0 90 3 0 220 5 0 100 3 0 240 5 0 110 3 0 260 5 0 120 3 0 280 5 0 130 3 0 300 5 0 140 3 0 320 5 0 150 3 5 340 5 0 160 3 5 360 5 0 170 3...

Страница 59: ...ida 33142 Drawing No 23 336 00025 Page 5 of 5 6 4 P N 336 00006 READING Knots TOLERANCE Knots READING Knots TOLERANCE Knots 20 5 0 140 4 0 30 5 0 150 4 0 40 3 5 160 4 0 50 3 0 170 4 0 60 3 0 180 4 0 7...

Страница 60: ...3 Page C of 38 SECTION 3 VERTICAL SPEED INDICATOR The following engineering specification Document 23 337 00025 details performance requirements of the pressure actuated vertical speed indicators used...

Страница 61: ......

Страница 62: ...ed as part number 337 00001 TYPE II to be identified as part number 337 00002 TYPE III to be identified as part number 337 00003 TYPE IV to be identified as part number 337 00004 4 Test Conditions Unl...

Страница 63: ...uring a 1 minute period With a pressure of 10 inches of mercury applied to the static connection the leakage shall not cause more than 0 05 inches of mercury pressure drop during a 1 minute period 5 6...

Страница 64: ...est Rate Ascent and Descent Feet Per Minute Tolerance Feet Per Minute 500 35 1 000 75 1 500 150 2 000 250 1 500 200 2 000 250 1 500 200 2 000 250 Maximum test point for Type I SCALE ERROR TOLERANCE TY...