manualshive.com logo in svg
background image

7960-464C

Page

1 of 11

This kit is designed to allow for vertical venting of the WG and WF Series products.  The kit
contains the necessary components to assemble and install a vertical vent on a WG or WF unit
requiring a five (5) foot vertical vent through an overhang.  The vent system is made of the highest
quality stainless steel for this application.  Additional lengths of vertical vents are available from your
dealer in two (2)* and five (5) foot increments for applications dictating longer venting requirements.

This kit includes the following components:

VERTICAL VENT KIT

VVK-5A for

WG and WF SERIES MODELS

Bard Manufacturing Company, Inc.
Bryan, Ohio 43506

.

y

t

Q

.

o

N

t

r

a

P

d

r

a

B

n

o

i

t

p

i

r

c

s

e

D

)

1

(

1

7

1

-

0

2

6

8

e

p

i

P

t

n

e

V

'

5

x

"

3

)

1

(

6

7

1

-

0

2

6

8

e

p

i

P

n

i

a

r

D

"

3

)

1

(

2

7

1

-

0

2

6

8

0

9

x

"

3

°

w

o

b

l

E

)

1

(

4

7

1

-

0

2

6

8

p

a

C

n

i

a

R

"

3

)

1

(

5

7

1

-

0

2

6

8

r

e

c

a

p

S

p

o

t

S

e

r

i

F

"

3

)

1

(

0

1

1

-

4

0

9

1

t

n

a

l

a

e

S

e

n

o

c

il

i

S

e

r

u

t

a

r

e

p

m

e

T

h

g

i

H

f

o

e

b

u

T

)

1

(

1

2

1

-

8

6

1

e

t

a

l

P

ll

i

F

t

i

n

U

)

1

(

1

5

0

-

1

2

9

1

t

e

k

s

a

G

e

t

a

l

P

ll

i

F

e

n

o

c

il

i

S

)

1

(

0

0

6

9

-

2

1

0

-

2

5

4

5

g

n

i

b

u

T

n

i

a

r

D

e

n

o

c

il

i

S

f

o

e

c

e

i

P

"

6

9

)

1

(

6

2

0

-

0

5

9

7

p

m

a

l

C

e

s

o

H

)

3

(

3

3

0

-

1

1

6

8

s

g

n

i

h

s

u

B

p

a

n

S

"

8

/

7

*

0

7

1

-

0

2

6

8

e

p

i

P

t

n

e

V

'

2

x

"

3

l

a

n

o

i

t

i

d

d

A

F r

o U e

s

h

t

i

w

0

3

G

W

,

4

2

G

W

d

n

a

M

6

3

G

W

s

l

e

d

o

)

1

(

6

4

1

-

8

6

1

x

o

B

n

i

a

r

D

t

n

e

V

)

1

(

7

4

1

-

8

6

1

p

o

T

x

o

B

t

n

e

V

)

1

(

8

4

1

-

8

6

1

m

o

t

t

o

B

x

o

B

t

n

e

V

)

2

(

0

0

8

0

-

7

1

0

-

3

1

9

1

)

n

o

r

o

P

(

t

e

k

s

a

G

m

a

o

F

)

1

(

8

0

4

0

-

7

1

0

-

3

1

9

1

)

n

o

r

o

P

(

t

e

k

s

a

G

m

a

o

F

)

4

1

(

6

8

0

-

2

1

0

1

s

w

e

r

c

S

l

a

t

e

M

t

e

e

h

S

"

2

/

1

            

WARNING

This venting system must be installed in accordance
with these instructions and Federal, state or local
codes.  Failure to do so could result in fire causing
property damage, personal injury, or loss of life.

Содержание VVK-5A

Страница 1: ... 2 6 8 p a C n i a R 3 1 5 7 1 0 2 6 8 r e c a p S p o t S e r i F 3 1 0 1 1 4 0 9 1 t n a l a e S e n o c i l i S e r u t a r e p m e T h g i H f o e b u T 1 1 2 1 8 6 1 e t a l P l l i F t i n U 1 1 5 0 1 2 9 1 t e k s a G e t a l P l l i F e n o c i l i S 1 0 0 6 9 2 1 0 2 5 4 5 g n i b u T n i a r D e n o c i l i S f o e c e i P 6 9 1 6 2 0 0 5 9 7 p m a l C e s o H 3 3 3 0 1 1 6 8 s g n i h s...

Страница 2: ...g silicone bead Remove dirt grease and moisture from surface to be sealed Dry surface or allow to dry thoroughly 2 Apply high temperature silicone approximately one half inch from end around male end of pipe and along both sides of seam for one inch in an even 1 4 bead as per Figure 1 3 Pipes can now be pushed together as far as they will go 4 Tighten gear clamps 15 In Lb max 5 Check for unrestric...

Страница 3: ... i r o H l a c i t r e V l a t n o z i r o H l a c i t r e V C 9 4 2 F 0 8 4 m m 0 0 2 8 m m 0 0 1 4 m m 5 2 1 A N 6 0 1 E G t n a l a e S t n e V Z x e l F Z 7 FOR VENTING MODELS WG24 WG30 WG36 REFER TO FIGURE 3 For these models a vent box is required to be installed on the front of the unit The drain tee is then supported by this box The drain line is also enclosed inside the box to protect it f...

Страница 4: ...7960 464C Page 4 of 11 FIGURE 2 VERTICAL VENTING INSTALLATION FOR WG24 WG30 WG36 MODELS ...

Страница 5: ...7960 464C Page 5 of 11 FIGURE 2A VERTICAL VENTING INSTALLATION FOR WG42 WG48 WG60 MODELS ...

Страница 6: ...7960 464C Page 6 of 11 FIGURE 2B VERTICAL VENTING INSTALLATION FOR ALL WF MODELS ...

Страница 7: ...Y AROUND TRANSITION DRAIN TUBE ATTACHES TO DRAIN STUB AND RUNS THROUGH BUSHING REMOVE 7 8 KNOCKOUT INSERT BUSHING STANDARD SCREWS INSERTED INTO EXISTING HOLES REMOVE EXISTING SCREW AND USE HOLE FOR BOX BOX WITH PORON GASKET ON BACK SIDE BENDS BOX TOP WITH PORON GASKET ON BACK TOP BEND DRAIN TEE DRAIN STUB STANDARD SCREW INSERTED INTO UNIT HOLE SELF DRILLING SCREWS USED TO ATTACH TEE TO TRANSITION ...

Страница 8: ...SEMBLY AND SEALS MODELS WG24 WG30 WG36 APPLY 8 PIECES OF PORON GASKET TO FLANGES OF DRAIN BOX APPLY 4 3 8 PIECE OF PORON GASKET ON BOX TOP DRAIN BOX BOX TOP BOX BOTTOM ATTACH BOTTOM OF BOX WITH 3 SCREWS TRIM 6 CHAMFERED CORNERS OPTIONAL MIS 1686 ...

Страница 9: ...7960 464C Page 9 of 11 FIGURE 4 INSTALLATION OF DRAIN TEE MODELS WF050 WF075 WF100 WF125 INDUCER MIS 2334 SEALANT CONNECTOR PART 8620 176 DRAIN FITTING DOWN DRAIN TEE STRAIGHT THRU INDUCER GASKET ...

Страница 10: ...cluded into the 7 8 holes Attach one end of the drain tubing to the drain tee fitting and secure with the hose clamp included Route the drain tubing as shown in Figure 5 as to form a trap in the line Make sure that the tubing is run through all four holes so it exits the lower unit base NOTE Do not use any other type of material for the purpose of draining this vent system Doing so could result in...

Страница 11: ...7960 464C Page 11 of 11 WF MODEL SHOWN FIGURE 6 FILL PLATE INSTALLATION MODELS WG42 WG48 WG60 AND ALL WF MODELS ...

Отзывы: