4-11
4.3.6
Encoder settings – properties
On the
Encoder properties
page the compression parameters are defined.
Use default
checked
default values are used, user settings are reset.
unchecked
values can be edited
Compression
Number of Inter Frames
Indicator for the number of inter frames between two intra frames
inter frame: characterizing the difference between two consecutive frames;
intra frame: complete autonomous frame
T
RANS
F
ORM
SCN reduces automatically the interval for intra frames, if fast changing
image contents are observed and additional bandwidth reduction can be achieved
this way.
The default value -1 corresponds to 100 inter frames.
Noise Threshold
Noise threshold defines how much the value of adjacent pixels within a color
plane might differ without being regarded as a change in color value.
Auto
stands for auto-selection of the best parameter with respect to noise and
optimal compression
Lossless
stands for lossless transfer of the images.
Values from
1
up to
16
are possible, where
16
stands for optimal compression but
may cause trails for moving objects.