R5906788-03
Thor series
162
B.1 About General Purpose Inputs & Outputs
(GPIO)
The Barco Cinema Controller and the Barco ICMP are equipped with GPIO ports. The electrical
specifications described in this chapter are the same for both GPIO ports.
General Purpose inputs
The Barco Cinema Controller and the Barco ICMP have each eight (8) opto-isolated general purpose inputs
available. These inputs are used to trigger the execution of macro files. For more explanation about the
association of a macro to a GPI, consult the user guide of the Communicator.
Input voltage
The inputs can be directly driven from a TTL or CMOS output.
•
The shape of the pulse must be rectangular.
•
The duration of the pulse must be at least 50 milliseconds (shorter pulses are considered as a switch
bounce)
•
Minimum voltage : V
min
= 3,3 V
•
Maximum voltage : V
max
= 24 V
External power supply
When interfacing with contact closure outputs, an external power supply needs to be provided. Depending
upon the configuration a suitable pull-up resistor needs to be added as well.
10k
820R
GPIn P
GPIn N
4.7V
Input to projector
Internal projector
1k1
+5V
to
+18V
10k
820R
GPIn P
GPIn N
4.7V
Input to projector
Internal projector
1k1
+5V
to
+18V
Image B-1
Cables
When long cable connections are required the use of shielded cables with twisted pairs is recommended. One
twisted pair is to be assigned to each GP Input pair.
How to make the connection
When the power supply used to provide the DC voltage is isolated from ground (for example in the case of an
AC adapter) it is recommended that the minus pole of that power supply is connected to ground (or to the
projector chassis). This will avoid high common mode voltages at the projector GP Inputs. If that same power
supply is used for other parts of the system, take care not to create ground loops. In any case when shielded
cables are used that shield should be connected to the projector chassis.
General Purpose outputs
The Barco Cinema Controller and the Barco ICMP have each eight (8) opto-isolated outputs available. Four
(4) of the outputs on the Cinema Controller are dedicated for TI. The other general purpose outputs can be
controlled via software.
About an output
The output can generate a falling edge, rising edge, toggle or continuous toggle.
•
Generate Falling Edge
–
generate a falling edge on the external GPO port if the present state of the
output is high. If the present state of the external GPO is low, no edge will be generated.
Содержание Thor Series
Страница 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Страница 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Страница 8: ...R5906788 03 Thor series 8...
Страница 24: ...R5906788 03 Thor series 24 Safety Information...
Страница 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Страница 44: ...R5906788 03 Thor series 44 Installation process...
Страница 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Страница 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Страница 110: ...R5906788 03 Thor series 110 Starting up...
Страница 122: ...R5906788 03 Thor series 122 Scheimpflug...
Страница 130: ...R5906788 03 Thor series 130 Convergence...
Страница 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Страница 160: ...R5906788 03 Thor series 160 Specifications...
Страница 168: ...R5906788 03 Thor series 168 Pin configurations...
Страница 172: ...R5906788 03 Thor series 172 Environmental information...
Страница 176: ...Glossary R5906788 03 Thor series 176...
Страница 181: ...R5906788 03 Thor series 181...
Страница 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...