5. Cabling of an TF-10 display
5.1
Power cabling of a TF-10 display
Power boxes
Barco provides several types of power boxes. Depending on the size of the TF-10 display you can choose to use the mono phase
power box or the custom made power box. The type of power box does not in
fl
uence the power cabling of the TF-10 display. See
installation manual of the concerned power box for installation instructions.
W
ARNING
:
To protect against risk of
fi
re by overloading of power cables, the amount of TF-10 tiles per power
source cable is limited. Never connect more than 6 TF-10 tiles with a power source cable.
Necessary parts
•
Power box(es) with matching cables.
•
Power linking cables.
•
Dummy power plugs
How to realize the power cabling of an TF-10 display ?
1. Install the power box nearby the TF-10 display. Ensure the power box provides as much power circuits as required to energize
the display in a safe manner. If necessary, install several power boxes. See manual of the used power box for installation
instructions.
2. Connect a power source cable coming from the power box with the lower tile in a column of 6 high.
Note:
Depending on the type of used power box, a multi power cable in combination with a spider connector is inserted between
the power box and the power source cable leading to the TF-10 tile. See manual of the used power box to realize the
cabling between power box and TF-10 display.
3. Create a power branch of maximum 6 tiles by placing a power linking cable between the tiles above. Note the lowest tile is
receiving power directly from the power box via a power source cable.
4. Place a dummy power plug on the power output socket of the upper tile in the power branch.
5. Make sure that all plug holder clamps are locked
fi
rmly.
6. Repeat from step 2 until all TF-10 tiles are provided with power.
Example of power cabling
The example below shows the power cabling of a four by six TF-10 display. The Power box is connected via a multi power cable
with a spider connector. Each spider output cable leads to a column of 6 TF-10 tiles. The power connection in this column is realized
with a power linking cable. Note that the unused power output socket is sealed with a dummy power plug.
38
R59770682 FIXED TF-10 DISPLAY 23/11/2011
Содержание TF-10
Страница 1: ...Fixed TF 10 display Installation Manual R59770682 02 23 11 2011 ...
Страница 4: ......
Страница 6: ...Table of contents 2 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Страница 12: ...1 Safety 8 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Страница 21: ...3 Components of a fixed TF 10 display Image 3 7 Image 3 8 R59770682 FIXED TF 10 DISPLAY 23 11 2011 17 ...
Страница 30: ...3 Components of a fixed TF 10 display 26 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Страница 40: ...4 Physical installation 36 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Страница 46: ...5 Cabling of an TF 10 display 42 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...
Страница 56: ...7 Specifications 52 R59770682 FIXED TF 10 DISPLAY 23 11 2011 ...