3. Advanced Commands
3.31.9
Read Minimum/Maximum Image files settings
Description
These commands read the min/max values of the image files settings
Commands
minimum total lines:
Command [0]
\x26
Command [1]
\x58
maximum total lines
Command [0]
\x27
Command [1]
\x58
minimum active lines
Command [0]
\x26
Command [1]
\x59
maximum active lines
Command [0]
\x27
Command [1]
\x59
minimum line start
Command[0]
\x26
Command[1]
\x5a
maximum line start
Command[0]
\x27
Command[1]
\x5a
Minimum period
Command [0]
\x26
Command [1]
\x5b
maximum period
Command [0]
\x27
Command [1]
\x5b
minimum total pixels
Command [0]
\x26
Command [1]
\x5c
maximum total pixels
Command [0]
\x27
Command [1]
\x5c
minimum active pixels
148