3. Advanced Commands
Command
Command [0]
\x21
Command [1]
\x92
Returned Data
Data[0]...Data[3] = signed double word XPosition : describes the start position of the window (x axis).
Data[4]...Data[7] = signed double word YPosition : describes the start position of the window (y axis).
Data[8]...Data[11] = signed double word Xsize : describes the “width” of the window (x axis).
Data[12]...Data[15] = signed double word Ysize : describes the “height” of the window (y axis).
Xsize, Ysize are given in “pixels”
3.2.22
PiP Window free size, Read Min/Max
Description
Reads the minimum/maximum value for the window free size adjustments in PiP.
Commands
read minimum:
Command [0]
\x26
Command [1]
\x92
read maximum:
Command[0]
\x27
Command[1]
\x92
Returned Data
Data[1]...Data[4] = signed double word XPosition : describes the min/max start position of the window (x axis).
Data[5]...Data[8] = signed double word YPosition : describes the min/max start position of the window (y axis).
Data[9]...Data[12] = signed double word Xsize : describes the min/max “width” of the window (x axis).
Data[13]...Data[16] = signed double word Ysize : describes the min/max “height” of the window (y axis).
Note that the panel size (projector version) can be read using the Panel size command
3.2.23
Window horizontal position, Write
Description
This command sets the horizontal position of the active window.
106
R5976884 RLM SERIES 04/04/2006