background image

6. Random Access Adjustment Mode

6.2 Random Access Overview

Random Access Overview

Picture Tuning
- Color Balance
- Contrast Modulation

o

Contrast Equalisation

o

Contrast Edge Correction

- Sync
- Peaking

o

Off

o

Low Source Frequency

o

Mid Source Frequency

o

High Source Frequency

- Clamp Mode
- Port 2
- Line Multiplier (Optional)

o

Motion Processing

o

Output Mode

o

Video Equalizing

o

Noise Reduction

o

Contrast Enhancement

o

Split Screen

o

Advanced Settings

o

Time Base Correction

o

Luminance Decay

o

V Sync Ref

o

Clamp Gating

o

Limo + Options

o

Coring

o

LTI

o

CTI

o

Factory Preset

Geometry
- Green Convergence
- H-Phase
- Raster Shift

o

Coarse Green

o

Coarse Red Horizontal

o

Coarse Blue Horizontal

o

Fine Green

o

Fine Blue

- Left / Right

o

Vertical Centerline

o

Side Precorrection

o

Left

o

Fine Side Correction

- Top / Bottom

o

Horizontal Centerline

o

Horizontal Top

o

Horizontal Bottom

- Size
- Fine Horizontal Adjustment
- Linearity

o

Coarse Linearity

o

Fine Vertical Linearity

o

Fine Horizontal Linearity

- Blanking

26

R5976633 BARCO GRAPHICS 908 / BARCO REALITY 908 05/06/2003

Содержание R9040004

Страница 1: ...Barco Graphics 908 Barco Reality 908 Owner s Manual R9040004 R9040006 R5976633 00 05 06 2003...

Страница 2: ...ne 1 937 372 7579 Fax 1 937 372 8645 E mail eis barco com Visit us at the web www eis barco com Barco nv Simulation Products Noordlaan 5 B 8520 Kuurne Phone 32 56 36 82 11 Fax 32 56 36 84 86 E mail in...

Страница 3: ...arks Brand and product names mentioned in this manual may be trademarks registered trademarks or copyrights of their respective holders All brand and product names mentioned in this manual serve as co...

Страница 4: ......

Страница 5: ...roduction 25 6 2 Random Access Overview 26 6 3 Selecting Setup Pattern 27 6 4 Picture Tuning 29 6 4 1 Starting up Picture Tuning 29 6 4 2 Color Balance 29 6 4 3 Contrast Modulation 30 6 4 4 Sync mode...

Страница 6: ...ojector Set Up 71 7 3 2 Identification 71 7 3 3 Total Run Time 72 7 3 4 Change Password 73 7 3 5 Change Projector Address 73 7 3 6 Change Baudrate 74 7 3 7 Projector Warm Up 75 7 3 7 1 Starting Up Pro...

Страница 7: ...ime Clock 96 7 6 I2C Diagnostics 97 7 7 Voltage Diagnostics 98 7 8 Projector Diagnostics 98 8 Messages Warnings and Failures 101 8 1 Messages 101 8 2 Warnings 101 8 3 Failures 102 Index 103 R5976633 B...

Страница 8: ...Table of contents 4 R5976633 BARCO GRAPHICS 908 BARCO REALITY 908 05 06 2003...

Страница 9: ...and serial number are located at the back side of the projector Record these numbers in the spaces provided below Refer to them whenever you call upon your BARCO dealer regarding this product Part Num...

Страница 10: ...e resuming operations Lightning For added protection for this video product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet Th...

Страница 11: ...ch have the same characteristics as the BARCO original part Unauthorized substitutions may result in degraded performance and reliability fire electric shock or other hazards Unauthorized substitu tio...

Страница 12: ...1 Safety Instructions 8 R5976633 BARCO GRAPHICS 908 BARCO REALITY 908 05 06 2003...

Страница 13: ...MAINS COMM PORT R G B Comp H Sync V Sync DEFOCUS 75 Ohm OFF ON 75 Ohm OFF ON red standby green operation X POS Y POS PORT 4 5 PORT 2 PROJECTOR MODE ON OFF 800 periphals See installation instructions b...

Страница 14: ...2 AC Power 10 R5976633 BARCO GRAPHICS 908 BARCO REALITY 908 05 06 2003...

Страница 15: ...ations Input Facilities RGBS or RGSB RGB3S or RG3SB R Y Y B Y S or R Y YS B Y Component Input R Y Y B Y 3S or R Y Y3S B Y Component Input POWER MAINS COMM PORT R G B Comp H Sync V Sync DEFOCUS 75 Ohm...

Страница 16: ...tal frequency of 32 kHz and higher To connect a source lower than 32 kHz an Optional Decoder Limo Pro R9828631 has to be installed Computer Port on projector R9828120 Magik Interface to computer to mo...

Страница 17: ...e RCU Button 4 on the RCU Sync on Green Button 5 on the RCU Separate Sync Table 3 3 Port 4 5 3 5 Component Video Source to Port 4 5 Which signal to Port 4 5 R Y Y B Y analog input terminals with sync...

Страница 18: ...from the projector to a hard memory device RS 232 OUT RS 232 OUT RS 232 IN RS 232 IN Computer Port on projector to computer Image 3 4 RS232 Connector How to set up the baud rate for the communication...

Страница 19: ...r The projector can be controlled by the local keypad or by the remote control unit Location of the local keypad The local keypad is located on the backside of the projector Remote control functions T...

Страница 20: ...standby button to start projector when the power switch is switched on and to switch off the projector without switching off the power switch Attention Switching to Standby When the projector is runn...

Страница 21: ...e 4 1 4 4 Switching on the projector How to switch on the projector 1 Press the mains ON OFF switch to switch on the projector Pressed ON Not Pressed OFF Table 4 2 Mains Power Switch COMM PORT R G B C...

Страница 22: ...burn in Every 30 seconds a text box will be displayed on another place on the screen with the remaining time to go The image dimensions can be adjusted with the cursor keys to avoid scanning on the ed...

Страница 23: ...t strikes the sensor window or if there are obstacles between the remote control unit and the projector s IR sensor F 1 F 2 F 3 F 4 F 5 A D J E X I T E N T E R P A U S E P H A S E T E X T S H A R P N...

Страница 24: ...0 or 1 The choice between 0 and 1 can be selected in the Service mode 4 6 2 Displaying and Programming addresses Displaying the Projector Address on the Screen 1 Press Address key recessed key on the...

Страница 25: ...dicates the current memorized setting for this source The bar scale changes as the or buttons of the control are pressed The sound controls can only be adjusted with the RCU Volume Volume control adju...

Страница 26: ...4 Getting Started 22 R5976633 BARCO GRAPHICS 908 BARCO REALITY 908 05 06 2003...

Страница 27: ...stment menus 1 Press the ADJUST key The Adjustment Mode menu will be displayed ADJUSTMENT MODE Select a path from below RANDOM ACCESS INSTALLATION SERVICE Select with or then ENTER EXIT to return Menu...

Страница 28: ...accessible without reentering the password When reentering the adjustment mode it will be necessary to enter your password again when selecting a password protected item When the password is wrong th...

Страница 29: ...stment Mode The main Adjustment Mode menu will be displayed 2 Push the or keys to highlight Random Access and press ENTER to select ADJUSTMENT MODE Select a path from below RANDOM ACCESS INSTALLATION...

Страница 30: ...n o Advanced Settings o Time Base Correction o Luminance Decay o V Sync Ref o Clamp Gating o Limo Options o Coring o LTI o CTI o Factory Preset Geometry Green Convergence H Phase Raster Shift o Coarse...

Страница 31: ...the projector If yes Push the or keys to highlight the desired setup pattern and press ENTER to select Choose a setup pattern from below SELECTED SOURCE GENLOCKED PATTERN INTERNAL PATTERN Select with...

Страница 32: ...1024 115 0 72 2048 x 1536 How to select the desired Cross Hatch Frequency To select a desired cross hatch frequency handle as follow 1 Push the or keys to highlight the desired Cross Hatch Frequency...

Страница 33: ...played PICTURE TUNING COLOR BALANCE CONTRAST MODULATION SYNC FAST PEAKING CLAMP MODE NORMAL PORT 2 VIDEO LINE MULTIPLIER Select with or then ENTER EXIT to return Menu 6 5 Depending on the input source...

Страница 34: ...d Cut Off 3 Push the or keys to adjust the Red Gain A bar scale indicates the amount of adjustment 4 Press ENTER to return to the Color Balance menu 5 Repeat step 3 to 5 for Green and Blue 6 Press EXI...

Страница 35: ...Contrast Modulation 1 Push the or keys to highlight Contrast Modulation and press ENTER to select PICTURE TUNING COLOR BALANCE CONTRAST MODULATION SYNC FAST PEAKING CLAMP MODE NORMAL PORT 2 VIDEO LIN...

Страница 36: ...he image The Contrast Equalization bar scale will be displayed bar scale 50 no correction 49 49 RV EQUAL RH EQUAL Image 6 2 Contrast Equalization bar scale 3 It can be an interaction of several adjust...

Страница 37: ...GREEN BLUE CONTRAST EDGE CORRECTION RED GREEN BLUE COLOR SELECT RED GREEN BLUE RG RB BG WHITE Select with or then ENTER EXIT to return Menu 6 12 2 Press EXIT to return to the Picture Tuning menu 6 4...

Страница 38: ...the corresponding peaking is switched on as default The Peaking menu will be displayed PEAKING OFF LOW FREQUENCY MID FREQUENCY HIGH FREQUENCY Select with or then ENTER EXIT to return Menu 6 15 The fol...

Страница 39: ...t 2 Video S Video Optional What can be done Port 2 can be used as Video or S Video input This menu item is only available when the projector is equipped with a Decoder Limo Pro R9828631 and if an S Vi...

Страница 40: ...setting of the line multiplier will be saved together with the source number Each time this source number is selected the last saved version will be loaded How to start up the Line Multiplier setting...

Страница 41: ...ENTER to select IMAGE PROCESSING MOTION PROCESSING ON OUTPUT MODE VIDEO EQUALIZING NOISE REDUCTION CONTRAST ENHANCEMENT SPLIT SCREEN OFF ADVANCED SETTINGS Select with or then ENTER EXIT to return Men...

Страница 42: ...nterlace mode 3 Press EXIT to return to the Image Processing menu 6 4 8 4 Video Equalizing What can be done The sharpness of the image can be adjusted for 3 frequency bands low medium and high separat...

Страница 43: ...OCESSING ON OUTPUT MODE VIDEO EQUALIZING NOISE REDUCTION CONTRAST ENHANCEMENT SPLIT SCREEN OFF ADVANCED SETTINGS Select with or then ENTER EXIT to return Menu 6 25 The Dynamic Noise Reduction bar scal...

Страница 44: ...NG ON OUTPUT MODE VIDEO EQUALIZING NOISE REDUCTION CONTRAST ENHANCEMENT SPLIT SCREEN OFF ADVANCED SETTINGS Select with or then ENTER EXIT to return Menu 6 27 2 Press ENTER to toggle Split Screen On Of...

Страница 45: ...essary When a color shift is recognized on the screen e g if color bars are projected and a line between the colors is recognized How to adjust Luminance Delay 1 Push the or keys to highlight Luminanc...

Страница 46: ...ss ENTER to toggle Vertical Sync Reference Direct Indirect 6 4 8 8 5 Clamp Gating When is it necessary Clamp Gating is useful when protection signals are present in the vertical interval of the video...

Страница 47: ...l be displayed 6 4 8 9 7 Coring What can be done With coring a noise threshold will be set for all filters How to adjust Coring 1 Push the or keys to highlight Coring and press ENTER to select LINE MU...

Страница 48: ...Y QUALIFIED PERSONNEL Select with or then ENTER EXIT to return Menu 6 35 The Coring bar scale will be displayed LTI 0 7 Image 6 10 LTI bar scale 2 Push the or keys to adjust the LTI value Note Only 7...

Страница 49: ...with or then ENTER EXIT to return Menu 6 36 The LTI bar scale will be displayed CTI 0 7 Image 6 12 CTI bar scale 2 Push the or keys to adjust the CTI value Note Only 7 steps are possible 3 Press EXIT...

Страница 50: ...ft Adjustment Left Right East West Adjustments Top Bottom North South Adjustments Size Adjustment Fine Horizontal Size Adjustment Linearity Adjustment Blanking Adjustments 6 5 1 Starting Up Geometry W...

Страница 51: ...rgence again and if a misalignment is still visible correct that with the convergence corrections How to toggle Green Convergence On Off 1 Push the or keys to highlight Green Convergence GEOMETRY GREE...

Страница 52: ...the Geometry menu 6 5 4 Raster Shift Adjustment WARNING It is necessary to look into the lenses to perform these adjustments To avoid eye discomfort while looking into the lenses reduce the contrast...

Страница 53: ...oarse Blue Horz 7 If necessary repeat step 4 till 5 to perform a Fine Raster Shift until the colors math each other Note Horizontal and Vertical shifts for Red and Blue should end up with a setting cl...

Страница 54: ...and skew of the vertical centerline How to adjust the Vertical Centerline 1 Push the or keys to highlight the Vertical Centerline and press ENTER to select LEFT RIGHT E W VERTICAL CENTERLINE SIDE PRE...

Страница 55: ...return Menu 6 45 2 Use the or keys to adjust the curvature of the vertical lines on both sides look only at he right side of the screen image Image 6 17 Side Precorrection Bow Adjustment 3 Use the or...

Страница 56: ...rection 1 Push the or keys to highlight the Fine Side Corrections and press ENTER to select LEFT RIGHT E W VERTICAL CENTERLINE SIDE PRECORRECTION LEFT FINE SIDE CORRECTION WARNING USE SIDE PRECORRECTI...

Страница 57: ...ments 1 Push the or keys to highlight Top Bottom N S and press ENTER to select GEOMETRY GREEN CONVERGENCE ON H PHASE RASTER SHIFT LEFT RIGHT E W TOP BOTTOM N S SIZE FINE H SIZE LINEARITY BLANKING Sele...

Страница 58: ...e top side of the image How to adjust Horizontal Top 1 Push the or keys to highlight Horizontal Top and press ENTER to select TOP BOTTOM N S HORIZONTAL CENTERLINE HORIZONTAL TOP HORIZONTAL BOTTOM Sele...

Страница 59: ...tal Bottom Bow Adjustment 3 Use the or keys to adjust the tilting of the horizontal lines on the bottom of the image Image 6 27 Horizontal Bottom Skew Adjustment 4 Press EXIT to return to the Top Bott...

Страница 60: ...a numeric indicator will help to gauge the size adjustment V SIZE H SIZE 70 Image 6 28 2 Push the or keys to adjust the horizontal size until the exact image width is obtained H size too large Ideal...

Страница 61: ...Fine Vertical Linearity Fine Horizontal Linearity 6 5 9 1 Starting Up the Linearity Adjustment What can be done For the standard projectors the horizontal vertical linearity adjustment functions corre...

Страница 62: ...o highlight Coarse Linearity and press ENTER to select LINEARITY COARSE LINEARITY FINE V LINEARITY FINE H LINEARITY Select with or then ENTER EXIT to return Menu 6 56 The Coarse Linearity bar scale wi...

Страница 63: ...the cursor keys to correct the Vertical Linearity of the image in this specific area 4 Press ENTER to save the correction and to return to the selection screen 5 Repeat step 2 till 4 for each area tha...

Страница 64: ...to the screen and to hide or black out unwanted information The following blanking adjustments are available Top Bottom Left Right If the internal pattern was selected this pattern remains on the scre...

Страница 65: ...1 Starting Up Convergence What has to be done Convergence adjustments affect both the horizontal and vertical lines of the setup pattern These adjustments are performed on the green image first if gr...

Страница 66: ...UE ON GREEN BLUE ON RED Select with or then ENTER EXIT to return Menu 6 61 The Convergence Selection menu will be displayed and the screen will be divided in 25 areas CONVERGENCE SEL select area using...

Страница 67: ...h or then ENTER EXIT to return Menu 6 63 The Convergence Selection menu will be displayed and the screen will be divided in 81 areas 2 Use the cursor keys to select one of the 81 areas and press ENTER...

Страница 68: ...tment For the digital adjustment the screen is divided into 25 areas which can be selected with a Select Area menu How to start up Focusing 1 Push the or keys to highlight Focusing and press ENTER to...

Страница 69: ...Top and press ENTER to select GREEN FOCUSING MIDPOINT TOP BOTTOM DIGITAL ADJUSTMENT Select with or then ENTER EXIT to return Menu 6 67 2 Push the cursor keys until the upper part of the image is sharp...

Страница 70: ...e digital focus adjustment and to toggle the cursor keys to the selection mode 5 Repeat step 2 till 4 for each area that needs an adjustment 6 When finished press EXIT to return to the Focusing menu 6...

Страница 71: ...to return to the Random Access Adjustment Mode menu 6 9 Soft Edge Optional When available Only available as an option for more explanation see SEMU manual 6 10 Driver Voltage Optional When available O...

Страница 72: ...r Voltage until there is just no distortion visible on the screen The dissipation inside the projector will be reduced If no Use the cursor keys to drive up the Driver Voltage a little and try again t...

Страница 73: ...TMENT MODE Select a path from below RANDOM ACCESS INSTALLATION SERVICE Select with or then ENTER EXIT to return Menu 7 1 The Service menu will be displayed SERVICE MODE PROJECTOR SET UP MEMORY MANAGEM...

Страница 74: ...to Midposition Common Settings Dynamic Astigmatism Gamma Correction CRT Run In Cycle CRT Drive Mode Memorybanks Flyback Turnover Point Menu Position option 1 Real Time Clock I2C Diagnostics Voltage D...

Страница 75: ...Front table Rear ceiling Rear table Baud rate PC transfer speed for communication with an IBM PC or compatible or MAC The baud rate of the projector must be the same as the baud rate of the connected...

Страница 76: ...FICATION TOTAL RUN TIME CHANGE PASSWORD CHANGE PROJECTOR ADDRESS CHANGE BAUDRATE PROJECTOR WARM UP POWER UP MODE operating COMMON ADDRESS 0 ABL CONTROLLER Select with or then ENTER EXIT to return Menu...

Страница 77: ...P MODE operating COMMON ADDRESS 0 ABL CONTROLLER Select with or then ENTER EXIT to return Menu 7 9 Note If it is the first time you enter a password protected item enter your password and press ENTER...

Страница 78: ...s to highlight the digit to be changed 3 Press a numeric key to enter the new digit 4 Repeat step 2 till 3 for the other digits 5 Press ENTER to save the new password 7 3 6 Change Baudrate What can be...

Страница 79: ...al amplitude of this white image with the cursor keys During this warm up period a full white image is shifted on the CRT faceplate to avoid a burn in Every 30 seconds a text box will be displayed in...

Страница 80: ...an be entered by selecting out of the displayed list an available block How to set the Warm Up Frequency 1 Push the or keys to highlight Frequency and press ENTER to select PROJECTOR WARM UP WARM UP O...

Страница 81: ...3 Press a numeric key to enter the new digit 4 Repeat step 2 till 3 for the other digits 5 Press ENTER to save the new Warm Up Time 6 Press EXIT to return to the Projector Set Up menu 7 3 8 Power Up M...

Страница 82: ...to return Menu 7 22 2 Press ENTER to toggle the Common Address between 0 and 1 3 Press EXIT to return to the Service Mode menu 7 3 10 ABL Controller What can be done To guarantee perfect dark images i...

Страница 83: ...L Timer ABL CONTROLLER ABL FORCED no ABL lines ABL TIMER 0 hours Set ABL timer to zero to disable the timer Timer only active in FORCED mode Select with or then ENTER EXIT to return Menu 7 25 2 Press...

Страница 84: ...ICS Select with or then ENTER EXIT to return Menu 7 27 The Memory Management menu will be displayed 7 4 2 Copy a Block What can be done This will copy the settings of the selected block into the activ...

Страница 85: ...e block you are working on Note All current softedge settings will be overwritten with the softedge settings of the block which is copied A confirmation screen will be displayed 4 Press ENTER to confi...

Страница 86: ...ce Midposition Focus to Midposition East West to Midposition North South to Midposition Digital Vertical Linearity Midposition Digital Horizontal Linearity Midposition Astigmatism Midposition All Sett...

Страница 87: ...to Midposition As long as the projector is playing on the same source same adjustment block it is possible to return to the previous settings Undo R B Convergence Mid is displayed in stead off R B Co...

Страница 88: ...Mid SET TO MIDPOSITION UNDO R B CONVERGENCE MID UNDO GREEN CONVERGENCE MID UNDO FOCUS TO MIDPOSITION UNDO E W TO MIDPOSITION UNDO N S TO MIDPOSITION UNDO DIG VERT LINEARITY MID UNDO DIG HOR LINEARITY...

Страница 89: ...ID GREEN CONVERGENCE MID FOCUS TO MIDPOSITION E W TO MIDPOSITION N S TO MIDPOSITION DIG VERT LINEARITY MID DIG HOR LINEARITY MID ASTIGMATISM MIDPOSITION ALL SETTINGS TO MIDPOS Select with or then ENTE...

Страница 90: ...TION UNDO R B CONVERGENCE MID UNDO GREEN CONVERGENCE MID UNDO FOCUS TO MIDPOSITION UNDO E W TO MIDPOSITION UNDO N S TO MIDPOSITION UNDO DIG VERT LINEARITY MID UNDO DIG HOR LINEARITY MID UNDO ASTIGMATI...

Страница 91: ...TO MIDPOSITION R B CONVERGENCE MID GREEN CONVERGENCE MID FOCUS TO MIDPOSITION E W TO MIDPOSITION N S TO MIDPOSITION DIG VERT LINEARITY MID DIG HOR LINEARITY MID ASTIGMATISM MIDPOSITION ALL SETTINGS T...

Страница 92: ...light Undo Astigmatism Midposition SET TO MIDPOSITION UNDO R B CONVERGENCE MID UNDO GREEN CONVERGENCE MID UNDO FOCUS TO MIDPOSITION UNDO E W TO MIDPOSITION UNDO N S TO MIDPOSITION UNDO DIG VERT LINEAR...

Страница 93: ...ngs to the previous settings 7 5 Common Settings Overview Starting Up Common Settings Dynamic Astigmatism Gamma Corrections CRT Run In Cycle CRT Drive Mode Memory Banks Flyback Turnover Point Menu Pos...

Страница 94: ...n the selected source or on a dot pattern lock on the selected source gen locked pattern Preparation 1 Press the Contrast Control key to increase the Contrast Level to near maximum 2 Press the Sharpne...

Страница 95: ...with ENTER Use the SHARPNESS keys for the defocusing of the image ENTER to continue EXIT to return Menu 7 54 2 Use the cursor keys to select one of the 25 areas and press ENTER to confirm and to togg...

Страница 96: ...e or keys to highlight Gamma Corrections and press ENTER to select COMMON SETTINGS DYNAMIC ASTIGMATISM GAMMA CORRECTIONS CRT RUN IN CYCLE CRT DRIVE MODE MEMORYBANKS ON FLYBACK TURNOVER POINT MENU POSI...

Страница 97: ...attern will be generated until EXIT is pressed The projector only uses memory blocks adjusted on an internal pattern if no such block is available the projector can t run the procedure and leaves the...

Страница 98: ...ne The user has the possibility to create 8 different memory banks formats for each source But the maximum allowed quantity of memory banks for all sources together is 32 The option to create differen...

Страница 99: ...e turnover point from long to short can be set by the user How to adjust the Flyback Turnover Point 1 Push the or keys to highlight Flyback Turnover Point and press ENTER to select COMMON SETTINGS DYN...

Страница 100: ...ow to toggle Option 1 On Off 1 Push the or keys to highlight Option 1 COMMON SETTINGS DYNAMIC ASTIGMATISM GAMMA CORRECTIONS CRT RUN IN CYCLE CRT DRIVE MODE MEMORYBANKS ON FLYBACK TURNOVER POINT MENU P...

Страница 101: ...s to highlight I2C Diagnostics and press ENTER to select SERVICE MODE PROJECTOR SET UP MEMORY MANAGEMENT COMMON SETTINGS I2C DIAGNOSTICS VOLTAGE DIAGNOSTICS PROJECTOR DIAGNOSTICS Select with or then E...

Страница 102: ...t 17V 17 1 Volt 9V 9 Volt 12V 11 9 Volt 12V 11 8 Volt 30V 29 8 Volt 40V 39 8 Volt 110V 110 Volt 210V 209 Volt HTHD 124 5 Volt conv 32 4 Volt conv 33 1 Volt foc_lo 28 8 Volt foc_hi 41 3 Volt EXIT to re...

Страница 103: ...EXIT to return Menu 7 74 2 Use the cursor keys to scroll through the failure log 3 Press ENTER to switch to the Voltage Diagnostics menu VOLTAGE DIAGNOSTICS 17V 16 9 Volt 17V 17 1 Volt 9V 9 Volt 12V 1...

Страница 104: ...7 Service Mode 100 R5976633 BARCO GRAPHICS 908 BARCO REALITY 908 05 06 2003...

Страница 105: ...ures will not be displayed PROJECTOR ADDRESS 003 Indication of the projector address when activating the ADDRESS button on the RCU with a pencil or other small object 8 2 Warnings Warnings WARNING Inp...

Страница 106: ...qualified service technician for repair FAILURE RCVDS communication error Serial communication error between the RCVDS and the projector FAILURE invalid input Input not valid FAILURE PC communication...

Страница 107: ...In Cycle 92 CTI 44 D Diagnostics 97 98 I2C 97 Projector 98 Voltage 98 Digital Adjustment 66 Driver Voltage Optional 67 Dynamic Astigmatism 90 E East West 49 Adjustments 49 Start up 49 F Factory Preset...

Страница 108: ...ess 19 73 Change 73 Controlling 19 Controlling 20 Set Up 70 71 Start up 71 Switch off 18 Switch on 17 Warm Up 75 Start Up 75 R Random Access 25 26 Introduction 25 Overview 26 Start up 25 Raster Shift...

Страница 109: ...l Centerline 50 Vertical Sync Reference 41 Video Equalizing 38 W Warm Up 76 77 Frequency 76 On Off 76 Time 77 Warm up period 18 Interrupt 18 Warnings 101 R5976633 BARCO GRAPHICS 908 BARCO REALITY 908...

Страница 110: ...Index 106 R5976633 BARCO GRAPHICS 908 BARCO REALITY 908 05 06 2003...

Страница 111: ...an 5 B 8520 Kuurne Phone 32 56 36 82 11 Fax 32 56 36 84 86 E mail info barco com Web www barco com From Date Please correct the following points in this documentation R5976633 00 page wrong correct R5...