1. PMP replacement Kit
1. PMP REPLACEMENT KIT
1.1 Introduction
Kit description
The PMP kit contains the 6000 series PMP
•
R763864
InfoT 386
This installation manual gives some background information about the R6000 software/PMP compatibility
The InfoT 386 handles this issue in detail.
PMP and Software compatibility
The change from V1.xx to V2.02 improved the uniformity alignment from a 1-level to a 3-level correction.
Upgrade to V3.xx is necessary for the NEW PMP board.
•
Soft V1.xx : 1-level uniformity correction for ALL color temperatures and Projector White.
•
Soft V2.02 onwards : 3-level uniformity corrections as follows :
6500°K: 2 levels = grey + full white
Projector White : 1 level = grey
Software version
Characterisitcs
V1.12
Std version
R6300
V3.01
- for new PMP
- 3 level unif
V1.12
Std version
R6400
V3.01
- for new PMP
- 3 level unif
V1.12
Std version
V2.02
- 3 level unif
R6400i
V3.01
- for new PMP
- 3 level unif
V1.12
Std version
V2.02
- 3 level unif
R6500
V3.01
- for new PMP
- 3 level unif
V1.xx to V2.02 Upgrade
In the new soft V2.02, because of the 3 levels, we have now two tables for corrections: one for 6500K and another one for PW.
Both tables MUST be filled in, they cannot remain "empty".
An upgrade from V1.xx to V2.02 is therefore not possible because these new tables will never be filled in by the upgrade. There are
no values available for these two tables.
There are two options when an upgrade is required :
R5976881 R6000 SERIES PMP 15/03/2005