5. Electronic spares and servicing procedures
5.5.3
Removing the PMP
Necessary tools
•
Torx screwdriver T10
•
nut spanner 4mm
How to remove the PMP?
1. Remove the connectors:
- J400 (2 wires): power from the power box (connector 6)
- J550 (6 wires): control signals from the local key pad / IR receiver
- J907 (30 wires): video / data signal to the formatter (connector J1)
- J913 (10 wires): control signals to the power box (connector 13)
- J915 (10 wires): I²C to the formatter (connector J2)
- GND (ground): remove the screw
Image 5-35
PMP: connectors
2. Remove the top screw
Image 5-36
PMP: fixing screw
3. Remove the screw and the six nuts on the front plate of layer one of the input box
R59770097 ID H250 / H500 15/05/2007
47