7. Mechanical spares and servicing procedures
Image 7-39
Location of the temperature sensor of the DMD
7.4
The lens holder
7.4.1
Removing the lens holder
Necessary tools
•
slotted screwdriver 4mm
•
Philips 2 screwdriver
•
Torx 10 screwdriver
•
open ended spanner 8mm
•
Allan key 2mm
How to remove the lens holder
1. Remove top and rear cover of the projector
2. Remove the PMP
3. Remove the input box
4. Remove the 7 screws, fixing the grid to the bottom side of the projector
Image 7-40
Screws of the filter cover
5. Remove the two screws fixing the lens holder to the frame on the bottom side of the projector
R59770097 ID H250 / H500 15/05/2007