2.19.2
Lamp Mode, Read
Description
Reads the actual Lamp mode of the projector
Command
Command [0]
\x21
Command [1]
\x0c
Returned Data
Data[0]: unsigned byte
data byte value: 0 = Single mode ; 1= Dual mode
Example
Reads the actual Lamp mode of the projector, the awnser being
\x00
= single mode.
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x0c
Checksum
\x44
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x0c
Data [0]
\x00
Checksum
\x2e
Stop
\xff