5. Troubleshooting
Code 8000: “Opening shutter failed” (Error)
Situation
Solution
Malfunction DC motor of the shutter
assembly.
Replace the shutter assembly. See "Replacement of the shutter", page 202.
Malfunction end-loop switch of the
shutter assembly.
Replace the shutter assembly. See "Replacement of the shutter", page 202.
Code 8001: “Closing shutter failed” (Error)
Situation
Solution
Malfunction DC motor of the shutter
assembly.
Replace the shutter assembly. See "Replacement of the shutter", page 202.
Malfunction end-loop switch of the
shutter assembly.
Replace the shutter assembly. See "Replacement of the shutter", page 202.
Code 8101: “Motor board calibration” (Error)
Situation
Solution
Calibration of one of the motorized
ranges failed (Vertical Shift,
Horizontal Shift, Zoom, Focus,
Shutter and Contrast Plate)
1.
Check the wiring and end-loop switches of all DC & stepper motors (Vertical Shift,
Horizontal Shift, Zoom, Focus, Shutter and Contrast Plate).
2.
Check if the latest
fi
rmware and software of the Motor Control Board is installed.
3.
Replace malfunction DC and/or stepper motors.
4.
Replace the Motor Control Board. See "Replacing the motor control board (MCB)",
page 283.
Code 8102: “Horizontal lens shift end of range” (Warning)
Situation
Solution
Horizontal Lens Shift not calibrated.
Calibrate the Horizontal Lens Shift.
End-loop switch disconnected.
Check the wiring of the two end-loop switches of the Horizontal Shift.
Malfunction end-loop switch.
Check the two end-loop switches and replace if necessary.
Corrupt
fi
rmware/software.
Reload the latest
fi
rmware and software version of the Motor Control Board.
Malfunction Motor Control Board.
Check the diagnostic LEDs of the Motor Control Board. Replace the Motor Control Board
if necessary. See "Replacing the motor control board (MCB)", page 283.
Code 8103: “Horizontal lens shift end of range” (Error)
This error code is probably preceded by the warning code 8103: “Horizontal lens shift end of range”. The same troubleshooting
table can be applied to.
Code 8104: “Vertical lens shift end of range” (Warning)
Situation
Solution
Vertical Lens Shift not calibrated.
Calibrate the Vertical Lens Shift.
End-loop switch disconnected.
Check the wiring of the two end-loop switches of the Vertical Shift.
Malfunction end-loop switch.
Check the two end-loop switches and replace if necessary.
Corrupt
fi
rmware/software.
Reload the latest
fi
rmware and software version of the Motor Control Board.
Malfunction Motor Control Board.
Check the diagnostic LEDs of the Motor Control Board. Replace the Motor Control Board
if necessary. See "Replacing the motor control board (MCB)", page 283.
Code 8105: “Vertical lens shift end of range” (Error)
This error code is probably preceded by the warning code 8104: “Vertical lens shift end of range”. The same troubleshooting table
can be applied to.
Code 8104: “Vertical lens shift end of range” (Warning)
Situation
Solution
Vertical Lens Shift not calibrated.
Calibrate the Vertical Lens Shift.
End-loop switch disconnected.
Check the wiring of the two end-loop switches of the Vertical Shift.
Malfunction end-loop switch.
Check the two end-loop switches and replace if necessary.
84
R5905312 HDF W SERIES 24/01/2013
Содержание HDF W series
Страница 1: ...HDF W series Service manual R5905312 01 24 01 2013 ...
Страница 4: ......
Страница 8: ...Table of contents 4 R5905312 HDF W SERIES 24 01 2013 ...
Страница 12: ...1 Safety 8 R5905312 HDF W SERIES 24 01 2013 ...
Страница 30: ...3 Preventative maintenance actions 26 R5905312 HDF W SERIES 24 01 2013 ...
Страница 35: ...5 Troubleshooting 5 TROUBLESHOOTING R5905312 HDF W SERIES 24 01 2013 31 ...
Страница 36: ...5 Troubleshooting 32 R5905312 HDF W SERIES 24 01 2013 ...
Страница 110: ...6 Removal and installation of the projector covers 106 R5905312 HDF W SERIES 24 01 2013 ...
Страница 111: ...7 Power Input 7 POWER INPUT R5905312 HDF W SERIES 24 01 2013 107 ...
Страница 112: ...7 Power Input 108 R5905312 HDF W SERIES 24 01 2013 ...
Страница 120: ...7 Power Input 116 R5905312 HDF W SERIES 24 01 2013 ...
Страница 172: ...10 Card Cage 168 R5905312 HDF W SERIES 24 01 2013 ...
Страница 182: ...11 Lamp Power Supply 178 R5905312 HDF W SERIES 24 01 2013 ...
Страница 183: ...12 Start Pulse Generator 12 START PULSE GENERATOR R5905312 HDF W SERIES 24 01 2013 179 ...
Страница 184: ...12 Start Pulse Generator 180 R5905312 HDF W SERIES 24 01 2013 ...
Страница 192: ...12 Start Pulse Generator 188 R5905312 HDF W SERIES 24 01 2013 ...
Страница 242: ...14 Lenses and Lens Holder 238 R5905312 HDF W SERIES 24 01 2013 ...
Страница 266: ...15 Liquid cooling circuit Image 15 39 Electrical connection 262 R5905312 HDF W SERIES 24 01 2013 ...
Страница 269: ...15 Liquid cooling circuit Image 15 45 Electrical connection R5905312 HDF W SERIES 24 01 2013 265 ...
Страница 270: ...15 Liquid cooling circuit 266 R5905312 HDF W SERIES 24 01 2013 ...
Страница 274: ...16 Heat exchanger Image 16 5 Remove assembly 270 R5905312 HDF W SERIES 24 01 2013 ...
Страница 280: ...16 Heat exchanger Image 16 13 276 R5905312 HDF W SERIES 24 01 2013 ...
Страница 309: ...19 Board Diagnostic LED s 19 BOARD DIAGNOSTIC LED S R5905312 HDF W SERIES 24 01 2013 305 ...
Страница 310: ...19 Board Diagnostic LED s 306 R5905312 HDF W SERIES 24 01 2013 ...
Страница 328: ...19 Board Diagnostic LED s 324 R5905312 HDF W SERIES 24 01 2013 ...