3. Components of an FLX display system
BARCO FLX
G3
▲
This controller
G4
Gamma
D1
D2
D3
Address:
12
►
Back
The arrow
▼
, in the lower right corner, which is pointing
downwards indicates that the list is longer than the LCD display.
Use the navigation buttons to scroll down to see the next items in
the list. An arrow
▲
in the upper right corner will appear.
The last item in the list is ’Back’ which can be used to go to the
previous menu.
Gamma
The transfer characteristics of most cameras and displays are nonlinear. For a display, a small change in amplitude
when the signal level is small produces a change in the display brightness level, but the same change in amplitude at a
high level will not produce the same magnitude of brightness change. This nonlinearity is known as gamma. Different
gamma curves are available to compensate the nonlinearity.
See user guide of the Director toolset to learn more about Gamma curves.
BARCO FLX
►
This controller
►
Info
Info page 1
Barco FLX, This controller, Info (1/3)
Address:
3
Temperature:
36°C
Ctrl serial :
<zzzzzzzzzzzz>
Board serial:
<xxxxxxxxxxxxxxxxxx>
Input(HxV): 1632x616
►
Continue
This menu displays information about this FLX-NNI Controller.
This menu has three pages. The
fi
rst page shows the address,
temperature, serial number of the FLX-NNI Controller, serial
number of the internal circuit board and the horizontal and vertical
resolution of the incoming data stream (IN) from the digitizer.
Press the select button to go to the next page (Continue).
Info page 2
Barco FLX, This controller, Info (2/3)
VERSIONS:
SoftWare:
1.0.0
Backup SW: 1.0.0
FirmWare:
1.0.0
Backup FW: 1.0.0
CPLD: 1.3
►
Continue
The second page of the info menu shows all the software/
fi
rmware
versions of this FLX-NNI Controller.
Info page 3
Barco FLX, This controller, Info (3/3)
OUT 1:
OK
OUT 5:
NC
OUT 2:
OK
OUT 6:
NC
OUT 3:
OK
OUT 7:
OK
OUT 4:
OK
OUT 8:
OK
►
Continue
The third page of the info menu shows the status of all eight
data output ports of this FLX-NNI Controller. ’OK’ means that
an FLX-HUB is connected with the output port. ’NC’ means that
no FLX-HUB was found.
BARCO FLX
►
This controller
►
Address
BARCO FLX
►
Up 10
This controller
Up 1
Address:
12
Down 1
Down 10
Back
Address:
12
This menu allows you to set the address of this FLX-NNI
Controller. The address can be set per step or per 10 steps. The
lowest address number is 0, the highest is 32767. Note that the
address number 0 is reserved for broadcasting. Each FLX-NNI
Controller is listening to the broadcast address 0 and to its own
address. So, it’s recommend to start the address numbering from
1 or higher.
BARCO FLX
►
This controller
►
LCD contrast
BARCO FLX
►
Up 10
This controller
Up 1
LCD contrast:
45
Down 1
Down 10
Back
Address:
12
This menu allows you to set the LCD contrast of this FLX-NNI
Controller. The LCD contrast can be adjusted between 0 and
255 in steps of 1 or 10.
R59770420 FLX-24 21/12/2009
25
Содержание FLX-24
Страница 1: ...FLX 24 Installation manual R59770420 00 21 12 2009...
Страница 6: ...Table of contents 2 R59770420 FLX 24 21 12 2009...
Страница 46: ...3 Components of an FLX display system 42 R59770420 FLX 24 21 12 2009...
Страница 56: ...4 Installation procedures Image 4 11 52 R59770420 FLX 24 21 12 2009...
Страница 72: ...B Specifications 68 R59770420 FLX 24 21 12 2009...
Страница 76: ...Index T This controller 24 U User interface 22 W Weight 67 Parts 67 72 R59770420 FLX 24 21 12 2009...