9. General operation example
9.4
Con
fi
guration Menu
Overview
Here, we de
fi
ne E2 components by adding inputs, backgrounds, outputs and destinations.
C1: Initial Setup
1. When you connect to an actual unit, instead of working of
fl
ine, the software should connect automatically. The unit is listed in the
System con
fi
guration page under the “Discovered” tab with the button on turning green.
2. Drop the E2 from the device area into the middle diagram area.
3. If multiple units are connected to the PC, the green LEDs next to the system name will turn green. You can assign a unique name
to each unit. In this application we will connect to only one unit and assign the name “Godzilla” to it. For online operations, you
can con
fi
rm that you are connected to the right unit by clicking the arrow in front of E2 to reveal the unit’s IP address. Verify that
this address is the same as the address listed on the unit’s front panel on the top status menu
Image 9-5
Note:
If the unit doesn’t connect automatically to the PC, you can type the PC’s IP address in the
fi
eld under “Manual Connect”.
4. For this application we will leave the default setting for Native rate: 59.94, Mode: 2K and Genlock: OFF.
C2: Add Background
1. Click on the “Background” tab to select the input that will be assigned as a background.
2. Click on the
+Add Background
blue button to enter the Add mode.
3. Click on the top DVI connector of slot 6 to select the input to de
fi
ne as background.
4. Click on the bottom DVI connector of slot 6 to select the input to de
fi
ne as background. We need to do this twice because the
background comes from a dual-head DVI card.
5. Click on the
Done Adding
button to exit the Add mode.
6. Double click on
Background1
in the Name list to edit the name.
7. When the area turns blue, click the eraser icon to clear the
fi
eld.
8. Type a new name, “PC-Background”. Hit enter when done.
Image 9-6
194
R5905948 E2 12/12/2014
Содержание Event Master E2
Страница 1: ...E2 User s guide R5905948 00 12 12 2014...
Страница 8: ...Table of contents 4 R5905948 E2 12 12 2014...
Страница 16: ...2 Safety 12 R5905948 E2 12 12 2014...
Страница 32: ...3 General 28 R5905948 E2 12 12 2014...
Страница 82: ...6 GUI orientation Image 6 8 78 R5905948 E2 12 12 2014...
Страница 94: ...6 GUI orientation Image 6 20 90 R5905948 E2 12 12 2014...
Страница 115: ...6 GUI orientation Image 6 37 Thumbnail view Image 6 38 R5905948 E2 12 12 2014 111...
Страница 186: ...7 System Setup 182 R5905948 E2 12 12 2014...
Страница 192: ...8 Updating firmware 188 R5905948 E2 12 12 2014...
Страница 196: ...9 General operation example Image 9 3 192 R5905948 E2 12 12 2014...
Страница 213: ...9 General operation example Image 9 25 R5905948 E2 12 12 2014 209...
Страница 216: ...9 General operation example 212 R5905948 E2 12 12 2014...
Страница 220: ...10 Maintenance 10 2 Process Overview Flow chart Image 10 2 216 R5905948 E2 12 12 2014...
Страница 226: ...10 Maintenance Image 10 11 2 Pull out the Front cover and lay it flat in front of the unit 222 R5905948 E2 12 12 2014...
Страница 281: ...10 Maintenance Disregard the heatsink from the spare kit R5905948 E2 12 12 2014 277...
Страница 282: ...10 Maintenance 278 R5905948 E2 12 12 2014...
Страница 286: ...11 Environmental information Republic of Turkey In conformity with the WEEE Regulation 282 R5905948 E2 12 12 2014...
Страница 288: ...11 Environmental information 284 R5905948 E2 12 12 2014...
Страница 298: ...B Remote Control Protocol 294 R5905948 E2 12 12 2014...
Страница 299: ...C Troubleshooting C TROUBLESHOOTING R5905948 E2 12 12 2014 295...
Страница 300: ...C Troubleshooting 296 R5905948 E2 12 12 2014...