6. Input & communication
6.4
About General Purpose Inputs & Outputs (GPIO)
General Purpose inputs
Eight (8) opto-isolated general purpose inputs are available, six (6) free and 2 dedicated inputs. These inputs are used to trigger the
execution of macro
fi
les. For more explanation about the association of a macro to a GPI, consult the user guide of the Communicator
touch panel.
Input voltage
The inputs can be directly driven from a TTL or CMOS output.
•
Minimum voltage : V
min
= 3,3 V
•
Maximum voltage : V
max
= 24 V
External power supply
When interfacing with contact closure outputs, an external power supply needs to be provided. Depending upon the con
fi
guration a
suitable pull-up resistor needs to be added as well.
100R
GPIn P
GPIn P
GPIn N
GPIn N
10k
Input to projector
Internal projector
1k1
+5V
to
+24V
Input to projector
+5V
to
+24V
100R
GPIn P
GPIn P
GPIn N
GPIn N
10k
Internal projector
1k1
Image 6-4
Cables
When long cable connections are required the use of shielded cables with twisted pairs is recommended. One twisted pair is to be
assigned to each GP Input pair.
How to make the connection
When the power supply used to provide the DC voltage is isolated from ground (for example in the case of an AC adapter) it is
recommended that the minus pole of that power supply is connected to ground (or to the projector chassis). This will avoid high
common mode voltages at the projector GP Inputs. If that same power supply is used for other parts of the system, take care not to
create ground loops. In any case when shielded cables are used that shield should be connected to the projector chassis.
General Purpose outputs
Eight (8) opto-isolated outputs are available, where seven are general purpose and one for a
fi
xed purpose. The seven general
purpose outputs can be controlled via software while the
fi
xed output provides the 3D output reference. When this output is closed
(current is
fl
owing), then the system is OK.
About an output
The output can generate a falling edge, rising edge, toggle or continuous toggle.
•
Generate Falling Edge
– generate a falling edge on the external GPO port if the present state of the output is high. If the
present state of the external GPO is low, no edge will be generated.
•
Generate Rising Edge
– generate a rising edge on the external GPO port if the present state of the output is low. If the present
state of the external GPO is high, no edge will be generated.
•
Generate Toggle
– generate a toggle on the external GPO port. If the present state of the output is low, a rising edge will be
generated, followed by a falling edge. If the present state of the output is high, a falling edge will be generated, followed by a
rising edge. The rate of toggle will be the vertical sync rate (edge transition at each vsync).
•
Generate Continuous Toggle
- This command will generate a continuous toggle of the external GPO port. This toggle will
continue until a
Generate Falling Edge
,
Generate Rising Edge
, or
Generate Toggle
command is received. The rate of toggle
will be the vertical sync rate (edge transition at each vsync).
Output transistor
•
Maximum output driving voltage : V
max
= 70 V
•
Maximum current : I
max
= 30 mA
•
Maximum power dissipation : 120 mW
62
R59770351 DP2K-20C 02/02/2010
Содержание DP2K--20C
Страница 1: ...DP2K 20C Installation manual R59770351 02 02 02 2010...
Страница 5: ...Projector Pb Hg Cd Cr6 PBB PBDE x o o o o o RoHS...
Страница 6: ......
Страница 29: ...3 Physical installation 1 2 3 5 4 7 6 Image 3 11 R59770351 DP2K 20C 02 02 2010 23...
Страница 82: ...8 Starting up 76 R59770351 DP2K 20C 02 02 2010...
Страница 90: ...9 Projector registration Image 9 9 Add new owner 84 R59770351 DP2K 20C 02 02 2010...
Страница 100: ...10 Removal and installation of projector covers Image 10 12 Top cover removal 94 R59770351 DP2K 20C 02 02 2010...
Страница 108: ...10 Removal and installation of projector covers 102 R59770351 DP2K 20C 02 02 2010...
Страница 120: ...11 Maintenance 114 R59770351 DP2K 20C 02 02 2010...
Страница 134: ...A Specifications 128 R59770351 DP2K 20C 02 02 2010...