4. Physical installation projector
Image 4-7
Terminal strip accessible
The terminal strip and connection plate is accessible.
4.3
Power input setup of the DPxK-36BLP
About the power input
The projector power input can be con
fi
gured for a power supply of 230/400V 3W+N+PE (
Υ
-connection) or for 208V 3W+PE (
Δ
-con-
nection). Before operating the projector, place the links in the correct position depending on the local power supply.
For a 3W+N+PE system, 400V is measured between the lines, 230V is measured between the lines and the neutral.
For a 3W+PE system, 208V is measured between the lines.
A
B
Image 4-8
Υ
-
Δ
connection
A
Υ
connection
B
Δ
connection
Necessary tools
•
Flat screw driver
•
Wrench 10 mm
•
Torque wrench 10 mm
How to switch from a
Υ
-connection to
Δ
-connection
1. Loosen the 6 top nuts on the
Υ
/
Δ
con
fi
guration block. (1 to 6)
30
R5906753 DPXK BLP SERIES 20/11/2017
Содержание DP2K-17BLP
Страница 4: ......
Страница 8: ...Table of contents 4 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 30: ...3 Installation process 26 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 40: ...4 Physical installation projector 36 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 120: ...10 Communicator Touch Panel Image 10 7 Connections 116 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 152: ...14 Maintenance 148 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 158: ...15 Convergence Green 1 5 4 6 5 Image 15 8 Green on blue convergence 154 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 162: ...16 Color calibration 158 R5906753 DPXK BLP SERIES 20 11 2017 ...
Страница 176: ...18 Specifications 172 R5906753 DPXK BLP SERIES 20 11 2017 ...