6. Lamp & lamp house
6.4
Installation of the xenon bulb lamp
W
ARNING
:
DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE OF
XENON BULB LAMP HANDLING OR SERVICE.
W
ARNING
:
This procedure may only be performed by quali
fi
ed technical service personnel.
C
AUTION
:
Xenon compact arc lamps are highly pressurized. When ignited, the normal operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accordance
to the manufacturer’s instructions. The bulb is stable at room temperature, but may still explode if dropped
or otherwise mishandled. Whenever the lamp house, containing a xenon bulb lamp, has to be dismantled or
whenever the protective container or cloth has to be removed from the xenon bulb lamp, authorized protective
clothing MUST be worn!
W
ARNING
:
Always wear face protection (full face shield with neck protector) when handling xenon bulb
lamps.
W
ARNING
:
Always wear protective clothing (welder’s jacket) when handling xenon bulb lamps.
W
ARNING
:
Always wear clean leather gloves with wrist protectors when handling xenon bulb lamps.
The DP-1500 projector is delivered without xenon bulb lamp installed. This procedure also assumes that the
lamp house is closed and that there is no xenon bulb lamp installed inside the lamp house.
Necessary tools
•
17 mm open ended wrench.
•
Torque wrench with 17 mm hexagon socket
•
Torque wrench with 5 mm Allen socket.
Necessary parts
•
Lamp cathode adapter.
•
Hexagon socket head screw M6 x 40.
•
Plane washer.
How to install the xenon bulb lamp into the lamp house?
1. Ensure that you wear protective clothing, a full face shield and protective gloves.
2. Remove the UV blocker and side cover of the lamp house by releasing the retaining thumbscrews as illustrated.
Note:
In case of a lamp replacement, the UV blocker will be already removed.
52
R59770091 DP-1500 06/01/2009
Содержание DP-1500
Страница 1: ...DP 1500 Installation manual R59770091 06 06 01 2009 ...
Страница 14: ...1 Operating conditions 10 R59770091 DP 1500 06 01 2009 ...
Страница 32: ...3 Mechanical set up of the DP 1500 28 R59770091 DP 1500 06 01 2009 ...
Страница 48: ...5 Lenses lens holder 44 R59770091 DP 1500 06 01 2009 ...
Страница 66: ...6 Lamp lamp house 62 R59770091 DP 1500 06 01 2009 ...
Страница 84: ...9 Starting up 80 R59770091 DP 1500 06 01 2009 ...
Страница 92: ...10 Projector registration Image 10 9 Add new owner 88 R59770091 DP 1500 06 01 2009 ...
Страница 126: ...12 Servicing 122 R59770091 DP 1500 06 01 2009 ...
Страница 142: ...13 Removal and installation of projector covers 138 R59770091 DP 1500 06 01 2009 ...
Страница 143: ...A Specifications A SPECIFICATIONS R59770091 DP 1500 06 01 2009 139 ...
Страница 144: ...A Specifications 140 R59770091 DP 1500 06 01 2009 ...
Страница 146: ...A Specifications 142 R59770091 DP 1500 06 01 2009 ...
Страница 154: ...C Pin configurations 150 R59770091 DP 1500 06 01 2009 ...
Страница 155: ...D Order info D ORDER INFO R59770091 DP 1500 06 01 2009 151 ...
Страница 156: ...D Order info 152 R59770091 DP 1500 06 01 2009 ...
Страница 158: ...D Order info 154 R59770091 DP 1500 06 01 2009 ...
Страница 160: ...Glossary 156 R59770091 DP 1500 06 01 2009 ...