background image

User Manual

Coronis

Содержание Coronis

Страница 1: ...User Manual Coronis...

Страница 2: ...This page intentionally left blank 2 This page intentionally left blank...

Страница 3: ...3 Using the online User Guide...

Страница 4: ...d guide booklet Gives a detailed description of the installation and connection of a complete system Online user guide html file Gives a detailed description of how to operate the display using its lo...

Страница 5: ...avorites Allows to add and remove help top ics to a list of favorites requires cookies Item Description Synchronize Press this button to show the loca tion of the help item in the Con tents Previous P...

Страница 6: ...User interface 6 Bookmark Press this button to bookmark the current help topic This topic will then appear in the web browser s Favorites menu requires cookies Item Description...

Страница 7: ...7 Graphic board information...

Страница 8: ...order to use the Barco portions of the Windows Display Control Panel to change any display settings 1 Open the Windows Display Control Panel by one of the two methods below a Start Settings Control Pa...

Страница 9: ...arco Tab Barco System Report The Barco System Report also known as BarcoMed SelfExam is a wizard based tool which collects data about the components that are installed in your system This information...

Страница 10: ...ct3D The OpenGL and Direct3D pages of the Advanced Properties page are divided into two sections Main Settings and Custom Settings Main Settings In the Main Settings section there is a slider bar whic...

Страница 11: ...ce option Your display will automatically adjust to the application s requirements Please refer to the on line help for more information on using advanced features such as Anisotropic Filtering SMOOTH...

Страница 12: ...is needed Please refer to the on line help for more information on using advanced features such as Mipmap Detail Level Device details The Device Details page provides detailed information about the di...

Страница 13: ...me of the new application for which you want to set the configuration parameters Modifying the configuration parameters To change the configuration settings of a specific application select the name o...

Страница 14: ...palette mode as configured by Windows Static Gray Palette including standard system colors This option sets the palette to be a static linear set of 236 gray values The 20 standard system colors are c...

Страница 15: ...are using Introduction After the BarcoMed Windows display controller driver is installed three new Display Properties tabs are available for configuring special features of the BarcoMed Coronis displa...

Страница 16: ...ettings tab 3 Select the rectangle that represents the Barco Coronis display whose settings you wish to change 4 Click on the Advanced button 5 Select the BarcoMed tab whose properties you wish to cha...

Страница 17: ...tDraw is not allowed in this mode User Modifiable Color Palette This option allows applications to modify the palette contents dynamically This mode reserves the first 10 and last 10 entries in the pa...

Страница 18: ...g the perceived range of colors in an image at the cost of spatial resolution Note This option is only available when the User Modifiable Palette mode is selected If either the Static Gray Palette inc...

Страница 19: ...lation if you wish to have RGB values equally weighted with 1 3 each When not selected then the International Commission on Illumination CIE Commission Internationale de I Eclairage model will be adap...

Страница 20: ...cted PCI slot Firmware Version Displays the firmware version for the BarcoMed display controller installed in the selected PCI slot Hardware Version Displays the Hardware Version for the BarcoMed disp...

Страница 21: ...output of a display controller Properties Clicking on this button provides detailed information about the currently selected display which is represented by the monitor icon with the black frame aroun...

Страница 22: ...If you are using a color display in conjunction with your Barco grayscale display s you should configure your desktop before setting the resolution of the your Barco grayscale display s You must have...

Страница 23: ...g the Color to Gray Compatibility palette mode the color setting for your high resolution grayscale displays should default to True Color 32 bits per pixel Even though this palette mode supports 32 bi...

Страница 24: ...BARCOMED CORONIS Display properties 24...

Страница 25: ...25 Display information...

Страница 26: ...display with the same image may result in some image sticking on the LCD panel Over 10 hours operation with the same image content is not recommended Switching on DPMS on display and PC and activating...

Страница 27: ...le no on screen display OSD is on the screen the front illumination is switched on for a few seconds When you touch a key again while the illumination is on the function of the key is executed Figure...

Страница 28: ...in Standby power saving mode Off Display is disconnected from the power or the LED s on state is disabled in the OSD Note When the LED is disabled in the OSD it will still be activated green when the...

Страница 29: ...press Enter to go into edit mode This is indicated by the scroll bar becoming longer Figure 3 Setting is selected Figure 4 Edit mode is active Use Up or Down to change the value Use Enter to confirm t...

Страница 30: ...Touch the Stand by touch key 2 A warning message appears Press the Stand by touch key again to switch the display into stand by or press any other key to keep the display in on state To switch from s...

Страница 31: ...y Indicates the actual measured y co ordinate color Luminance target Allows to manually adjust the lumi nance target See note below Color target Allows to select from a list of fac tory defined and us...

Страница 32: ...reached Color definition submenu Available only on color displays A color target is defined by its luminance target and color temperature The color definition submenu allows to edit these values Stabi...

Страница 33: ...inates This function is not available when the Native White color target is selected y Allows to define the y co ordinate of the color temperature that corre sponds to the color target This function i...

Страница 34: ...y OSD 34 Restore factory x y val ues Allows to reset the x y co ordi nates of the color temperature to the factory values This function is not available when the Native White color target is selected...

Страница 35: ...tion This function is available only when the DICOM DF is selected Name Description Measured ambient light Indicates the ambient light actually measured by the ambient light sen sor on the front of th...

Страница 36: ...ALC Allows to switch continuous DICOM ALC on off When switched on the DICOM DF is recalculated continuously taking the averaged ambient light into account When switched off the DICOM DF is recalculate...

Страница 37: ...the averaged ambient light determined by the selected reading room is taken into account This function is available only when Continuous DICOM ALC is off Reading room Allows to select from a pre defin...

Страница 38: ...On screen display OSD 38 Calibration info Jumps to the calculation informa tion submenu which displays infor mation about the values taken into account to recalculate the DICOM DF Name Description...

Страница 39: ...e reading room type you are editing You can select another room to edit by using the Up or Down touch keys Max ambient light This indicates the maximum ambi ent light that corresponds to the selected...

Страница 40: ...i ent light value is stored here over writing the former value However if the averaged ambient light value is higher than the maxi mum ambient light value that cor responds to the selected reading roo...

Страница 41: ...DF Dark luminance Shows the dark luminance value taken into account to calculate the DICOM DF Ambient correction Shows the ambient light correction value taken into account to calcu late the DICOM DF...

Страница 42: ...t idle for a certain time ULT Allows to switch ULT uniform light technology on off Panel orientation Allows to set panel position to auto portrait or landscape In auto posi tion the firmware detects t...

Страница 43: ...de the OSD must not be visible Touch any of the soft touch keys to switch on the front illumination While the illumination is on touch the following keys in successive order Enter Down Up Down Enter S...

Страница 44: ...and by Backlight Life time Indicates the total time the display has been operating excluding the time in stand by Service Opens the Service information submenu Firmware Opens the Firmware information...

Страница 45: ...On screen display OSD 45 Display stock no The order number for the display Panel ser no The LCD panel serial number Panel prod date The LCD panel production date Name Description...

Страница 46: ...FPGA2 Name Description Display lifetime The time the display has been operating including power save mode Backlight life time The time the backlight has been operat ing This is also the time the displ...

Страница 47: ...y the I Guard IGuard X value The X value of the color measured by the I Guard IGuard Y value The luminance Y measured by the I Guard IGuard Z value The Z co ordinate of the color measured by the I Gua...

Страница 48: ...width of the horizontal blanking Hor front porch The width of the horizontal front porch Hor sync The width of the horizontal sync Hor back porch The width of the horizontal back porch Hor frequency T...

Страница 49: ...sted until the target is reached The I Guard sensor constantly measures the luminance and color temperature color displays only These measurements are used to adjust and stabilize the luminance and co...

Страница 50: ...ft touch keys The front illumination is switched on 2 While the illumination is on touch the Enter touch key to display the main menu 3 Use the Up or Down touch keys to select the Luminance and Color...

Страница 51: ...enu 3 Use the Up or Down touch keys to select the Luminance and Color menu Use Enter to open the menu 4 Use Up or Down to select Color Definition Use Enter to open the submenu 5 Select the color targe...

Страница 52: ...co ordinates first make sure the color target is defined in x y co ordinates see step 7 Use Up or Down to select x or y Use Enter to go into edit mode Use Up or Down to change the value Use Enter to s...

Страница 53: ...y 3 parameters Maximum Ambient Light defines the maximum light allowed in this type of room This value can be adjusted within certain limits determined by the selected reading room Preset Correction V...

Страница 54: ...results in more visible grayscales in the images Dynamic Gamma 2 2 Dynamic Gamma 1 8 These are gamma functions that are shifted to take into account the non zero luminance of an LCD panel when driven...

Страница 55: ...en another DICOM Offset is selected To switch continuous DICOM ALC on off 1 Select the DICOM display function See To select a display function DF on page 53 2 In the Display Function menu use Up or Do...

Страница 56: ...into edit mode 4 Use Up or Down to select an offset 5 Use Enter to save the changes You can select the following offsets Value Description Dark Room The DICOM DF will be recalculated taking an ambient...

Страница 57: ...nuous DICOM ALC on off on page 55 3 In the ALC DICOM Options menu use Up or Down to select Reading Room Use Enter to go into edit mode 4 Use Up or Down to select the reading room that corresponds to t...

Страница 58: ...ght conditions in diagnostic reading rooms for com puted radiology digital radiology or mammography This setting has the lowest maximum ambient light CT MR NM Corresponds to light conditions in diagno...

Страница 59: ...by the selected reading room 6 To modify the Preset correction value for this reading room use Up or Down to select Preset Corr Value Use Enter to go into edit mode Use Up or Down to change the value...

Страница 60: ...Enter again to store the value Switching DPMS on off Operating precautions Continuous operation of the display with the same image may result in some image sticking on the LCD panel Over 10 hours oper...

Страница 61: ...ct Power LED Use Enter to go into edit mode 5 Use Up or Down to select On or Off 6 Use Enter to save the changes Note When the display is switched in stand by the power LED will turn orange even if th...

Страница 62: ...the OSD Now the user cannot display the OSD again until the user controls keycode is entered see below To enable the user controls again 1 To enter the user controls keycode the OSD must not be visibl...

Страница 63: ...63 Barco web sites...

Страница 64: ...Internet addresses 64 Internet addresses Visit Barco at http www barco com Visit Medical Imaging at http www barco com medical...

Страница 65: ...www barco com B4100533 01 May 2006...

Отзывы: