background image

K5902060 /09

Coronis 3MP LED Display

26

4.12 Viewing modes

About viewing modes

The Coronis 3MP LED Display can be used in two viewing modes:

Diagnostic:

This mode provides the full calibrated luminance and is intended for using the display for

diagnostic purposes.

Text:

In this mode, the luminance is reduced to approximately half of the luminance. This is intended for

using the display with office applications such as word processing.
Please note that text mode is not persistent, once powered off, the unit will restart in diagnostic mode.

To quickly switch the viewing mode without having to enter the OSD menu, touch the left and right
key at the same time during normal operation.

The diagnostic mode should always be selected when the Coronis 3MP LED Display is intended to
be used in a diagnostic environment.

To select a viewing mode:

1.

Bring up the OSD main menu.

2.

Navigate to the

Configuration > Calibration

menu.

3.

Enter the

Viewing Mode

submenu.

4.

Select

Diagnostic/Text

as desired and confirm.

4.13 Display functions

About display functions

Native, uncorrected panels will display all grayscale/color levels with luminance increments that are not
optimal for crucial diagnostic information. Studies have shown however, that in medical images certain
grayscale/color parts contain more diagnostic information then others. To respond to these conclusions,
display functions have been defined. These functions emphasize on these parts containing crucial diagnostic
information by correcting the native panel behavior.

The available display functions for your Coronis 3MP LED Display are:

Native:

If you select Native, the native panel behavior will not be corrected.

Dynamic Gamma 1.8

or

2.2

: These are gamma functions that are shifted to take into account the non-zero

luminance of an LCD panel when driven with a

black

signal. They are especially useful in CT applications

to improve the perception of low Hounsfield values.

DICOM:

DICOM (Digital Imaging and Communications in Medicine) is an international standard that was

developed to improve the quality and communication of digital images in radiology. In short, the DICOM
display function results in more visible grayscales in the images. Barco recommends selecting the DICOM
display function for most medical viewing applications.

User:

This display function will be automatically selected when display functions are defined by MediCal

QAWeb.

Gamma 1.8

or

2.2

: Select one of these display functions in case the display is to replace a CRT display

with a gamma of 1.8 or 2.2 respectively.

The settings of the display must be adapted to suit the requirements of the visualization software. In
case of doubt, please contact the vendor of the visualization software.

To select a display function:

1.

Bring up the OSD main menu.

2.

Navigate to the

Configuration > Calibration

menu.

Advanced operation

Содержание Coronis 3MP LED MDCG-3221

Страница 1: ...ENABLING BRIGHT OUTCOMES MDCG 3221 User Guide Coronis 3MP LED Display...

Страница 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com...

Страница 3: ...tor lights 18 3 3 Standby switching 19 3 4 Bringing up the OSD menus 19 3 5 Navigating through the OSD menus 20 3 6 I Luminate 20 4 Advanced operation 21 4 1 OSD menu language 22 4 2 OSD menu automati...

Страница 4: ...ale conversion modes 32 4 23 EDID timings 33 4 24 Display info 33 4 25 Display status 33 5 Repackaging instructions 35 5 1 Replacing the protection buffer 37 5 2 Repacking your display 37 6 Cleaning y...

Страница 5: ...5 K5902060 09 Coronis 3MP LED Display Welcome 1...

Страница 6: ...klights Barco s Coronis 3MP LED Display is as low in power consumption as it is high in brightness Additionally Barco s LED backlights are mercury free produce less heat and last longer This allows Ba...

Страница 7: ...0 09 Coronis 3MP LED Display 7 1 3 Product overview Front 2 1 3 4 5 6 7 8 Image 1 1 1 USB A 2 0 downstream connector 2 Left key 3 Right key 4 Menu key 5 Standby key 6 Power status LED 7 Front sensor W...

Страница 8: ...video input 4 DVI video input 5 Ethernet connector1 6 USB B 2 0 upstream connector 7 USB A 2 0 downstream connector 8 Connector compartment cover 9 Kensington security lock 10 VESA mount cover plate...

Страница 9: ...are using a Barco display controller please consult the user guide delivered with it to do this For a list of compatible display controllers please refer to the latest version of the compatibility ma...

Страница 10: ...ilt the panel upwards before changing the orientation Image 2 2 3 To change from portrait to landscape turn the panel counterclockwise 4 To change from landscape to portrait turn clockwise If after in...

Страница 11: ...ltaneously will result in driver errors To connect the signal cables to the display To get access to the connectors remove the connector compartment cover See Removing the connector compartment cover...

Страница 12: ...external DC power supply to the 24 Vdc power input of the display 5 Plug the mains connector of the external DC power supply to a grounded power outlet by means of one of the supplied power cables Im...

Страница 13: ...se this to move the display Please refer to the instruction manual of the arm for more information and instructions WARNING Use an arm that is approved by VESA according to the VESA 100 mm standard Us...

Страница 14: ...clean and soft surface Be careful not to damage the panel screen 3 Remove the plastic cover with a flathead screw driver Image 2 11 4 Slide the plastic cover over the neck of the foot Image 2 12 5 Rem...

Страница 15: ...you have properly installed your display and display controller the Windows start up messages will appear once the boot procedure is finished Your Coronis 3MP LED Display will be running in a basic vi...

Страница 16: ...K5902060 09 Coronis 3MP LED Display 16 Display installation...

Страница 17: ...17 K5902060 09 Coronis 3MP LED Display Daily operation 3...

Страница 18: ...ased on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit without affecting the diagnostic performance of the prod...

Страница 19: ...or approximately 2 seconds As a result the display will switch on or will switch to standby mode In case of a power outage recovery your display will always start up in the power mode it was in before...

Страница 20: ...above the keys adapted to the function that it is used for menu dependent I Luminate is not available while the OSD menu is activated Overview key icons Left Right Menu Enter Cancel Standby IEC 60417...

Страница 21: ...21 K5902060 09 Coronis 3MP LED Display Advanced operation 4...

Страница 22: ...ace Menu menu 3 Enter the Automatic Close submenu 4 Select Enabled Disabled as desired and confirm 4 3 Power status indicator light About the power status indicator light By default when the display i...

Страница 23: ...Ethernet over USB About Ethernet over USB By default the Ethernet over USB will be disabled This does not disable the USB hub and still allows to make use of the display s USB downstream connectors an...

Страница 24: ...s desired and confirm 4 8 DPMS mode About DPMS mode Enabling the Display Power Management System DPMS mode on your display will optimize its diagnostic lifetime by automatically switching off the back...

Страница 25: ...The I Luminate default mode defines the default activated mode during the I Luminate boost This mode is Screen The boost mode is applied on the screen display To enable disable I Luminate 1 Bring up...

Страница 26: ...others To respond to these conclusions display functions have been defined These functions emphasize on these parts containing crucial diagnostic information by correcting the native panel behavior Th...

Страница 27: ...composed a list of pre defined reading rooms Each of these reading rooms are defined by following parameters the maximum light allowed in this type of room the preset ambient light correction value fo...

Страница 28: ...display using the OSD menus described in the next sections Embedded QA will use the front sensor I Guard to measure the necessary luminance levels for either a calibration or compliance test Various...

Страница 29: ...ion is shown Time elapsed since latest calibration Display Function Ambient Light Compensation and Reading Room Current DICOM Settings Display Function Shows the current display function Ambient Light...

Страница 30: ...he DICOM compliance can be modified in steps of 5 starting from 5 to 30 When the maximum deviation is not bigger than the selected threshold the compliance check will be OK To set the DICOM error thre...

Страница 31: ...t corresponding to the DVI connector Automatic Selection The input is automatically selected To manually select a video input signal 1 Bring up the OSD main menu 2 Navigate to the Configuration Image...

Страница 32: ...ayscale conversion modes About grayscale conversion modes Grayscale conversion modes specify how color generated on the display controller is converted to grayscale in your display The available grays...

Страница 33: ...elect Refresh Rate Preferred Orientation or Color Depth 5 Select one of the available settings and confirm 4 24 Display info About display info Your display serial number native resolution firmware ve...

Страница 34: ...K5902060 09 Coronis 3MP LED Display 34 Advanced operation...

Страница 35: ...35 WARNING Before repacking the display follow the instruction to replace the foot protection buffer to prevent damage to the display K5902060 09 Coronis 3MP LED Display Repackaging instructions 5...

Страница 36: ...isplay 36 Overview of the packaging 1 2 3 4 5 6 7 8 Image 5 1 Packaging 1 Bottom box 5 Box Power supply cables 2 Bottom buffer 6 Top buffer 3 Protection buffer 7 Top box 4 Display 8 Display controller...

Страница 37: ...put the panel in landscape orientation see Adjusting the display position page 10 5 Place the connector compartment cover in the protection buffer 6 Slide the protection buffer over the foot of the di...

Страница 38: ...60 09 Coronis 3MP LED Display 38 4 Put the top buffer on top of the display 5 Slide the top box over the bottom box 6 Use the three lock bayonets to lock the box 1 2 3 x 3 Image 5 3 Repackaging instru...

Страница 39: ...39 K5902060 09 Coronis 3MP LED Display Cleaning your display 6...

Страница 40: ...Alcohol solvents at higher concentration 5 Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia Detergents with abrasives Steel wool Sponge with abrasives Steel bl...

Страница 41: ...41 K5902060 09 Coronis 3MP LED Display Important information 7...

Страница 42: ...ly no applied part The equipment shall not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the sam...

Страница 43: ...using serious injury to a child or adult and serious damage to the device Malfunctions Disconnect the equipment s power cord from the AC inlet and refer servicing to qualified service technicians unde...

Страница 44: ...land RoHS RoHS Barco RoHS MCV According to the Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products Also called RoHS of Chinese Mainland the...

Страница 45: ...o the photo is based on the Standard of Electronic Information Products Environmental Friendly Use Period of Chinese Mainland 10 7 3 Regulatory compliance information Intended use The display is inten...

Страница 46: ...es or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC responsible Barco Inc 3059 Premiere Parkway Suite 400 30...

Страница 47: ...or an experienced technician for help Electromagnetic immunity The Coronis 3MP LED Display is intended for use in the electromagnetic environment specified below The customer or the user of the Coroni...

Страница 48: ...0 4 3 3 V m 80 MHz to 2 7 GHz 3 V m Immunity to RF wireless communications equipment Test frequency MHz Band MHz Service Modulation Maximum power W Distance m Immunity test level V m 385 380 390 TETRA...

Страница 49: ...e is approved according to the UL Demko regulations S E Indicates the device is approved according to the CCC regulations Indicates the device is approved according to the VCCI regulations Indicates t...

Страница 50: ...e Caution Consult the operating instructions Indicates this device must not be thrown in the trash but must be recycled according to the European WEEE Waste Electrical and Electronic Equipment directi...

Страница 51: ...though every attempt has been made to achieve technical accuracy in this document we assume no responsibility for errors that may be found Our goal is to provide you with the most accurate and usable...

Страница 52: ...angle H V 178 Uniform Luminance Technology ULT Yes Per Pixel Uniformity PPU Yes Ambient Light Compensation ALC Yes Backlight Output Stabilization BLOS Yes I Guard Yes Maximum luminance 1700 cd m typi...

Страница 53: ...ctive non reflective glass cover Recommended modalities All digital images except digital mammography Certifications FDA 510 K K131246 for General Radiology CE1639 MDD 93 42 EEC A1 2007 47 EC class II...

Страница 54: ...THE COPYRIGHTHOLDER OR ANY OTHER CONTRIBUTOR BE LIABLE FOR DIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES HOWEVER CAUSED AND ON ANY TH...

Страница 55: ...K5902060 09 Coronis 3MP LED Display 55 Important information...

Страница 56: ...NV Beneluxpark 21 8500 Kortrijk Belgium Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com K5902060 09 2019 03 29 Barco NV President Kennedypark 35 8500 Kortrijk B...

Отзывы: