E. Troubleshooting
E. TROUBLESHOOTING
E.1 Error codes
Overview
When the error code is preceded by a ’-’ sign, then the error means a real error for the projector.
When the error code is preceded by a ’+’ sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
code
Description
Error
Warning
Caused by
Action
1001
Wrong lamp 1
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1002
Wrong lamp 2
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1003
Wrong lamp 3
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1004
Wrong lamp 4
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1011
Lamp 1 missing
Yes
Yes
No lamp inserted in position 1
Insert a lamp in position 1
1012
Lamp 2 missing
Yes
Yes
No lamp inserted in position 2
Insert a lamp in position 2
1013
Lamp 3 missing
Yes
Yes
No lamp inserted in position 3
Insert a lamp in position 3
1014
Lamp 4 missing
Yes
Yes
No lamp inserted in position 4
Insert a lamp in position 4
1021
Lamp 1 broken
Yes
-
Lamp 1 is not ON
Check installation of lamp 1
(connection, cable, etc.)
1022
Lamp 2 broken
Yes
-
Lamp 2 is not ON
Check installation of lamp 2
(connection, cable, etc.)
1023
Lamp 3 broken
Yes
-
Lamp 3 is not ON
Check installation of lamp 3
(connection, cable, etc.)
1024
Lamp 4 broken
Yes
-
Lamp 4 is not ON
Check installation of lamp 4
(connection, cable, etc.)
1399
I²C open error
Yes
1398
I²C read error
Yes
1397
I²C write error
Yes
1699
Formatter busy
1697
Formatter init
failed
Yes
-
no communication with formatter
ctrl
Call a quali
fi
ed service engineer
1696
Formatter ctrl
init failed
Yes
-
no communication with formatter
ctrl
Call a quali
fi
ed service engineer
1695
Formatter start
failed
Yes
-
no communication with formatter
Call a quali
fi
ed service engineer
1693
1692
1691
2100
LPS 1 error
Yes
-
Replace LPS
2400
LPS 2 error
Yes
-
Replace LPS
2700
LPS 3 error
Yes
-
Replace LPS
3000
LPS 4 error
Yes
-
Replace LPS
R59770021 CLM R10+ 15/03/2010
207
Содержание CLM R10+ R9050100
Страница 1: ...CLM R10 Users manual R9050100 R90501001 R59770021 10 15 03 2010 ...
Страница 14: ...1 Safety 10 R59770021 CLM R10 15 03 2010 ...
Страница 22: ...2 General 18 R59770021 CLM R10 15 03 2010 ...
Страница 35: ...3 Physical installation Skew Image 3 28 Skew adjustment R59770021 CLM R10 15 03 2010 31 ...
Страница 36: ...3 Physical installation 32 R59770021 CLM R10 15 03 2010 ...
Страница 48: ...5 Connections 44 R59770021 CLM R10 15 03 2010 ...
Страница 64: ...7 Start up of the Adjustment mode 60 R59770021 CLM R10 15 03 2010 ...
Страница 74: ...8 Input menu 70 R59770021 CLM R10 15 03 2010 ...
Страница 115: ...10 Layout menu Image 10 61 Image 10 62 Image 10 63 Image 10 64 R59770021 CLM R10 15 03 2010 111 ...
Страница 116: ...10 Layout menu 112 R59770021 CLM R10 15 03 2010 ...
Страница 158: ...13 Projector control 154 R59770021 CLM R10 15 03 2010 ...
Страница 172: ...14 Service menu 168 R59770021 CLM R10 15 03 2010 ...
Страница 186: ...16 Servicing 182 R59770021 CLM R10 15 03 2010 ...
Страница 195: ...17 Projector covers removal and installation Image 17 18 Secure the lamp door R59770021 CLM R10 15 03 2010 191 ...
Страница 196: ...17 Projector covers removal and installation 192 R59770021 CLM R10 15 03 2010 ...
Страница 204: ...C DMX Chart 200 R59770021 CLM R10 15 03 2010 ...
Страница 210: ...D Specifications 206 R59770021 CLM R10 15 03 2010 ...
Страница 216: ...E Troubleshooting 212 R59770021 CLM R10 15 03 2010 ...
Страница 222: ...F Mounting optional Carry handle 218 R59770021 CLM R10 15 03 2010 ...
Страница 224: ...G Order info 220 R59770021 CLM R10 15 03 2010 ...
Страница 232: ...Index 228 R59770021 CLM R10 15 03 2010 ...