background image

1

Declaration of Performance

1.

Unique identification code of the product-type

2.

Intended use or uses of the construction product, in 
accordance with the applicable harmonised technical 
specification, as foreseen by the manufacturer

3.

Name, registered trade name or registered trade mark 
and contact address of the manufacturer as required 
pursuant to Article 11(5)

4.

Where applicable, name and contact address of the 
authorised representative whose mandate covers the 
tasks specified in Article 12(2)

5.

System or systems of assessment and verification of 
constancy of performance of the construction product 
as set out in Annex V

6.

In case of the declaration of performance concerning a 
construction product covered by a harmonised 
standard

7.

Declared performance

Fire safety

Distance to combustible materials

Minimum distances, in mm
Insulation thickness rear =

100

Insulation thickness sides =

100

Insulation thickness ceiling =

75

Front = 

1800

Insulation thickness floor =

30

NPD

Thermal output

Energy efficiency

8.

Signed for and on behalf of the manufacturer by:

Danny Baijens, CEO
(Name and function)

Bladel;  February 1, 2021

………………………………………………………………………..

(place and date of issue)

(Signature)

The performance of the product identified in point 1 is in conformity with the declared performance in point 7.

This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 3.

Water heating output

- kW

Pass

Nominal heat output

10 kW

Room heating output

10 kW

Electrical safety

Pass

Cleanability

Pass

Maximum operating pressure

Not applicable

Flue gas temperature at nominal heat output

T = 319 °C

75.6 %

NPD

Pass

Pass

Declaration of Performance

According to regulation (EU) 305/2011

No.  1.816.003-3 - CPR-2013/07/01

Unilux-7 70

Room heater without hot water supply

Barbas Bellfires BV; Hallenstraat 17; 5531 AB  Bladel; The Netherlands

Not applicable

System 3

The notified laboratory SGS Nederland BV, No. 0608 performed the 
determination of the product type on the basis of type testing under system 3 
and issued test report EZKA/2015-02/00001-22 & EZKA-2020-11-030-1

Harmonized technical specification

EN13229:2001/A2:2004/AC:2007

Essential characteristics

Performance

CO = 0.07 vol%

Emission of combustion products

Mechanical resistance (to carry a chimney/flue)

Surface temperature

Risk of burning fuel falling out

Release of dangerous substances

Pass

Declaration of Performance

4

Unilux-7 70

Содержание Unilux-7 70

Страница 1: ...User manual Unilux 7 70 Serial number Production date...

Страница 2: ...ise without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this documen...

Страница 3: ...th regard to the environment 10 5 Fuel 11 5 1 Fuel types 11 5 2 Fuel amount 11 6 Operation 12 6 1 Preparation before first use 12 6 2 First use of the appliance 13 6 3 Firing the appliance 13 6 3 1 Fi...

Страница 4: ...ion Bladel February 1 2021 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in point 7 This declaration of performa...

Страница 5: ...ent show a typical setup The illustrations are for instructional use only 2 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety c...

Страница 6: ...r inlet D Grate E Steel bottom plates F Log guard G Ash tray under the grate H Ceramic panels I Top flue connector1 J Control lever K Convection air outlet 2 Figure 1 Top view of the Unilux 7 70 with...

Страница 7: ...ir inlet M Air wash inlet N Adjustable feet O Upper baffle steel P Lower baffle ceramic Q Connection for external combustion air Figure 2 Bottom view of the Unilux 7 70 with screened door Description...

Страница 8: ...d logs or wood briquettes as fuel Do not use other fuels The appliance is intended for use with the door closed The appliance may only be used at the location that meets the requirements for the insta...

Страница 9: ...Wear the glove and use the operating hook or a poke when refilling the appliance Make sure that your clothing does not touch the appliance Especially synthetic clothing ignites easy and burns intense...

Страница 10: ...nmentally friendly way Dispose of ceramic heat resistant glass as household waste Do not dispose of ceramic heat resistant glass in a glass recycling container Dispose of an obsolete appliance accordi...

Страница 11: ...shly chopped wood Coal anthracite and other bituminous fuels Lignite peat Using unsuitable fuels cause excess smoke black glass combustible deposits in the chimney and can damage the appliance 5 2 Fue...

Страница 12: ...ing the door handle Steel frame door Turn the handle forward to open the door Turn the handle downward to close the door Screened glass door Turn the handle forward to open the door Turn the handle ba...

Страница 13: ...hob cleaner 6 3 Firing the appliance 6 3 1 First load and ignition At the beginning the appliance and chimney are cold It is important that both the appliance and chimney reach a temperature that guar...

Страница 14: ...d logs crosswise on top of the first layer of wood logs 7 Put kindling wood and 2 to 4 fire starter cubes on top of the wood logs 8 Put kindling wood above the fire starter cubes 9 Light the fire star...

Страница 15: ...ers in the fire bed add suitable kindling to prevent excessive smoke Note The procedure hereunder is a general description The best reloading moment is dependent on the flue draught A high flue draugh...

Страница 16: ...d airwash inlet is closed Warning Setting the control lever in the far left position all air inlets closed when the fuel is burning leads to excessive emission of hazardous gasses example carbon monox...

Страница 17: ...nt flow of the flue gas in the chimney Do the next steps to decrease the flow resistance 1 Loosen the nut above the heat shield with a 3 mm hexagonal key and a 10 mm fork spanner Unscrew the socket sc...

Страница 18: ...for advice on the required fuel quality Make sure the door of the appliance is closed when in use Only open the door for ignition and to refuel Do not remove all the ashes An ash layer in the combust...

Страница 19: ...ere are no glowing embers 2 Remove the ashes with a small scoop 3 Lift the grate with the operating hook and remove the grate 4 Remove the ashtray and empty it 5 Make sure there are no ashes in the sp...

Страница 20: ...the recommended ignition procedure Refer to chapter 6 3 1 Use the recommended amount of fuel Refer to chapter 5 2 The wood logs burn too fast Primary air inlet is open Close the primary air supply Ad...

Страница 21: ...e wood logs is too high Use dried wood logs with a moisture content of 10 20 Use wood briquettes The seal around the door is damaged Contact your dealer Some cold air flows out from the front of the a...

Страница 22: ...l heat output net 10 kW Minimum heat output net 8 kW Useful efficiency Net Calorific Value NCV at nominal heat output 75 6 Useful efficiency Net Calorific Value NCV at minimum heat output indicative 8...

Страница 23: ...after they have manifested themselves 3 Complaints will only be accepted if they are reported to the Barbas dealer together with the serial number of the Barbas appliance which is stated on the front...

Страница 24: ...oes not automatically imply that Barbas Bellfires B V also accepts liability for any possible damage The liability of Barbas Bellfires B V never extends further than that stated in these warranty cond...

Страница 25: ...Warranty Terms Unilux 7 70 25...

Страница 26: ...Warranty Terms 26 Unilux 7 70...

Страница 27: ...Warranty Terms Unilux 7 70 27...

Страница 28: ...Your Barbas dealer 001 25 03 2021 350988...

Отзывы: