barbas UNICA 50 Скачать руководство пользователя страница 1

INSTRUCTIONS FOR USE 

                        INSTALLATION INSTRUCTIONS

 

COUNTRY 

NATURAL GAS 

PROPANE

  GREAT-BRITAIN / IRELAND 

UNICA 50  NG 

UNICA 50  PG

   

UNICA 52  NG 

UNICA 52  PG

   

UNICA 65  NG 

UNICA 65  PG

   

UNICA 70  NG 

UNICA 70  PG

   

UNICA 100  NG 

UNICA 100  PG 

UNICA 50

UNICA 52

UNICA 65

UNICA 70

UNICA 100

Содержание UNICA 50

Страница 1: ...N INSTRUCTIONS COUNTRY NATURAL GAS PROPANE GREAT BRITAIN IRELAND UNICA 50 NG UNICA 50 PG UNICA 52 NG UNICA 52 PG UNICA 65 NG UNICA 65 PG UNICA 70 NG UNICA 70 PG UNICA 100 NG UNICA 100 PG UNICA 50 UNIC...

Страница 2: ......

Страница 3: ...A 65 UNICA 50 UNICA 52 CONTENTS 1 INSTRUCTIONS FOR USE 2 INSTALLATION INSTRUCTIONS 3 MAINTENANCE 4 FAULTS 5 ELECTRICAL DIAGRAM 6 DIMENSIONS 7 TECHNICAL DETAILS REGULATIONS 8 REPLACEMENT PARTS LIST Pag...

Страница 4: ...4 UNICA 70 UNICA 100 UNICA 65 UNICA 52 UNICA 50...

Страница 5: ...is system shuts off the appliance if the flue gas is not exhausted 1 2 1 Safety Do not place any embers vermiculite granules or logs against the pilot light burner Make sure that the pilot flame can b...

Страница 6: ...y the thermostatic knob and or the sliding knob The thermostatic knob is used to choose the correct setting and the modulating thermostat ensures that the set temperature 13 38 C is maintained The sli...

Страница 7: ...times to ignite the pilot light Check through the glass that the pilot light has been lit l When the pilot light is lit keep the thermostat knob pushed in for a further 10 seconds after which it can...

Страница 8: ...supply valve to the fire Important If the pilot flame goes out for any reason wait for 5 minutes before attempting to re light it l If the pilot light frequently goes out then please contact your inst...

Страница 9: ...ning the pressed knob A further to the left to the ignition position from the symbol to the small flame symbol A click is heard indicating the ignition spark for the pilot light If necessary click a f...

Страница 10: ...the gas supply from the minimum position to the OFF position 1 7 4 Remote control The remote control operates according to the ultrasonic principle and consists of a hand held transmitter and a recie...

Страница 11: ...C F Heating period P1 and P2 Time display Button High MAN Setting TIMER Setting TIME Button Low MAN Setting TIMER Setting TIME SENDsymbol AUTO TIMER MAN display Button AUTO Button TIMER Figure 4 Hand...

Страница 12: ...he TIMER button 1 7 7 Set the current time l After connecting the batteries or when simultaneously pressing AUTO and TIMER the display flashes You are in SET mode l Press to set the hour and to set th...

Страница 13: ...the timer program turns to heating cycle off the motor will turn the valve to pilot and there is no temperature control This minimizes battery consumption l You may press AUTO to verify the set temper...

Страница 14: ...Remove the battery support from the housing and release it from the contact holder l Remove the batteries from the battery support l Place the 4 new batteries of 1 5V type LR6 or AA in the battery sup...

Страница 15: ...iance is used Heating of these particles by the convection system of the appliance could lead to discoloration of the walls and ceiling It is therefore very important to ensure that the room in which...

Страница 16: ...bar then it is recommended to reduce it Before beginning the installation check that the details on the rating plate correspond to the gas type and pressure to which the appliance will be connected 2...

Страница 17: ...e regulations 1 NATURALLY VENTILATED HOUSE see Figure 6 l The room in which the appliance is to be fitted must have a non closable combustion air supply opening The minimum dimensions are detailed in...

Страница 18: ...itted must have a non closable combustion air supply opening The minimum dimensions are detailed in Technical Details Regulations at the rear of this manual see also Paragraph 2 4 point 4 l The flue g...

Страница 19: ...COMBUSTION AIR SUPPLY The combustion air supply has to comply with national and local regulations The minimum dimensions are detailed in Technical Details Regulations at the rear of this manual The ai...

Страница 20: ...ce as applicable Paragraph 2 5 1 Fitting into a new chimney Paragraph 2 5 2 Fitting into an existing opening larger than the fire insert Paragraph 2 5 3 Fitting into an existing opening equal or small...

Страница 21: ...e into the flue spigot of the appliance For further installation procedures refer to Paragraph 2 5 1 2 5 3 Fitting into an existing opening equal to or smaller than the fire insert If the opening in t...

Страница 22: ...ica 52 Dismantle the door including the glass by loosening the Unica 65 screws at the top and bottom Dismantle the front by loosening all screws around the door opening Wear protective gloves when han...

Страница 23: ...ca 65 nuts at the front Next turn the adjustment bolt downwards at the left and right hand side bottom which slightly lowers the inner shell compared to the outer casing The inner shell can be removed...

Страница 24: ...ot can be removed by loosening the self tapping screws from the inside of the outer casing The appliance is now fully dismantled Figure 9 Unica 52 Unica 65 Front Flue spigot Outer casing Inner shell C...

Страница 25: ...om the connector and guide the cable through the special openings to the wall socket on which during installation there must be no tension Slightly lower the insulated aluminium or flexible stainles s...

Страница 26: ...ert nuts securely CHECK THAT THE SEALING CORD OF THE FLUE SPIGOT IS CORRECTLY CONNECTED 3 FITTING THE CONTROL UNIT First of all make the elctrical connection when dismantled on the connector on the ri...

Страница 27: ...insert See Chapter 1 Instructions for use 5 POSITIONING THE CERAMIC LOG SET The appliance is delivered with a set of artificial wooden logs and vermiculite and or embers Unica 50 and Unica 100 Import...

Страница 28: ...ing and place them evenly on and around the burner Note Small embers and their residue should not be scattered on the burner This can cause a blockage on the burner orifices 2 Distribute the vermiculi...

Страница 29: ...pt unblocked Note Small embers and their residue should not be scattered on the burner This can cause a blockage on the burner orifices 2 Place the logs on the burner according to figure 11 Figure 11...

Страница 30: ...holder behind the burner After that position the 5 remaining logs no and with the sharp sides pointed downwards See figure 12 PROPANE APPLIANCE Unica 52 P Positioning of the log set is the same as tha...

Страница 31: ...holder behind the burner After that position the 5 remaining logs no and with the sharp sides pointed downwards See figure 13 PROPANE APPLIANCE Unica 65 P Unica 70 P Positioning of the log set is the...

Страница 32: ...be scattered on the burner This can cause a blockage on the burner orifices 2 Place the two rear logs behind the burner with the carbon side to the front See figure 14 3 Place the remaining logs acco...

Страница 33: ...fully remove the embers 1 x125 gram from the packaging and place them evenly on and around the burner Please make sure that all burner orifices small holes are kept unblocked See figure 16 Note Small...

Страница 34: ...burner Figure 17 UNICA 100 PROPANE appliance Position of embers and logs on burner Positioning the rear logs The carbon side to the top Embers must not be placed next to the pilot light burner Make s...

Страница 35: ...d in the door the door can be screwed to the front 7 FITTING THE OPERATING HATCH ES Unica 50 Fit the operating hatch on the right hand side of the opening Unica 70 Press the left hinge pin and positio...

Страница 36: ...f logs on and around the main burner according to the installation directions in this instruction booklet Do not place any embers vermiculite granules or logs against the pilot light burner Make sure...

Страница 37: ...alfunction of the thermal one way protection safety system Check by means of testing l Insufficient gas pressure l Pilot light is dirty l Thermocouple voltage too low This is usually caused by insuffi...

Страница 38: ...GRAM blue brown yellow green brown brown brown blue yellow green Fanspeed controller convection fan 230 VAC 50 Hz Convection fan 230 VAC 50 Hz Thermostat Clickson set at 40 C Earthed plug with earth s...

Страница 39: ...39 UNICA 70 UNICA 100 UNICA 65 UNICA 50 UNICA 52 6 DIMENSIONS 6 1 UNICA 50 Gas connection...

Страница 40: ...40 UNICA 70 UNICA 100 UNICA 65 UNICA 52 UNICA 50 6 2 UNICA 52 Gas connection 525 fi xed frame fixed frame...

Страница 41: ...41 UNICA 70 UNICA 100 UNICA 65 UNICA 50 UNICA 52 6 3 UNICA 65 Gas connection fi xed frame fixed frame...

Страница 42: ...42 UNICA 70 UNICA 100 UNICA 65 UNICA 52 UNICA 50 6 4 UNICA 70 fi xed frame Plateau fixed frame Gas connection...

Страница 43: ...43 UNICA 70 UNICA 100 UNICA 65 UNICA 50 UNICA 52 6 5 UNICA 100 fixed frame fi xed frame Gas connection...

Страница 44: ...0 mbar Gas regulator block hand control SIT 0 630 704 SIT 0 630 704 Min heatinput adj screw Thermostatic burner no 160 1 60 mm no 100 1 00 mm Manual burner standard standard Gas regulator block remot...

Страница 45: ...burner standard standard Gas regulator block remote control Mertik GV 34 Mertik GV 34 Main burner Barbas 242 x 122 2 row Barbas 242 x 122 2 row Primary air inlet main burner 2x 8 5 mm 4x 8 5 mm 1x 6...

Страница 46: ...60 1 60 mm no 130 1 30 mm Manual burner standard standard Gas regulator block remote control Mertik GV 34 Mertik GV 34 Main burner Barbas 360 x 122 2 row Barbas 360 x 122 2 row Primary air inlet main...

Страница 47: ...mm no 130 1 30 mm Manual burner standard standard Gas regulator block remote control Mertik GV 34 Mertik GV 34 Main burner Barbas 360x122 2 row HZ Barbas 360x122 2 row HZ Primary air inlet main burne...

Страница 48: ...with cable 9 302411 Cable 10 305966 Main burner natural gas G20 1x 8 5 2x 6 5 11 305967 Main burner propane G31 8x 8 5 12 301927 Main burner injector natural gas no 90 13 301937 Main burner injector...

Страница 49: ...360 mm 29 301592 Fibre glass tape 15 x 3 mm l 1300 mm 30 301607 Black fibre glass cord 6 mm l 1950 mm 31 301614 Black fibre glass tape 10x2 mm l 290 mm 32 301669 Tube ceramic glue 33 322372 Log set U...

Страница 50: ...ing SIT 0 160 022 15 301207 Pilot light pipe 4 mm l 340 mm 16 301976 Pilot light olive 4 mm 17 301977 Pilot light nut 4 mm 18 302070 Pilot light electrode cable l 500 mm 19 302060 Pilot light injector...

Страница 51: ...ICA 100 UNICA 65 UNICA 50 UNICA 52 No Part no Description Hand Remote control control 33 301669 Tube ceramic glue 34 301845 Log set Unica 52 natural gas and propane 35 301839 Vermiculite granules 5 gr...

Страница 52: ...9 Pilot light set outer casing SIT 0 160 022 15 301207 Pilot light pipe 4 mm l 340 mm 16 301976 Pilot light olive 4 mm 17 301977 Pilot light nut 4 mm 18 302070 Pilot light electrode cable l 500 mm 19...

Страница 53: ...emote control control 32 301607 Black fibre glass cord 6 mm l 2220 mm Unica 65 33 301614 Black fibre glass tape 10 x 2 mm l 375 mm 34 301669 Tube ceramic glue 35 301844 Log set Unica 65 Unica 70 natur...

Страница 54: ...15 301207 Pilot light pipe 4 mm l 340 mm 16 301976 Pilot light olive 4 mm 17 301977 Pilot light nut 4 mm 18 302070 Pilot light electrode cable l 500 mm 19 301974 Pilot light injector natural gas no 5...

Страница 55: ...55 UNICA 70 UNICA 100 UNICA 65 UNICA 50 UNICA 52...

Страница 56: ...04 010507 303430 INTERFOCOS B V HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E mail info barbas nl Internet www barbas com...

Отзывы: